Literature DB >> 23370985

Stability of mid-shaft clavicle fractures after plate fixation versus intramedullary repair and after hardware removal.

Sean D Smith1, Coen A Wijdicks, Kyle S Jansson, Robert E Boykin, Frank Martetschlaeger, Peter-Paul de Meijer, Peter J Millett, Tom R Hackett.   

Abstract

PURPOSE: Operative treatment for middle-third clavicle fractures has been increasing as recent data has demonstrated growing patient dissatisfaction and functional deficits after non-operative management. A controlled biomechanical comparison of the characteristics of locked intramedullary (IM) fixation versus superior pre-contoured plating for fracture repair and hardware removal is warranted. Therefore, the purpose of the present study was to investigate potential differences between these devices in a biomechanical model.
METHODS: Thirty fourth-generation composite clavicles were randomized to one of five groups with 6 specimens each and tested in a random order. The groups tested were intact, repair with plate, repair with IM device, plate removal, and IM device removal. The lateral end of the clavicles was loaded to failure at a rate of 60 mm/min in a cantilever bending setup. Failure mechanism, energy (J), and torque (Nm) at the site of failure were recorded.
RESULTS: Failure torque of the intact clavicle (mean ± standard deviation) was 36.5 ± 7.3 Nm. Failure torques of the IM repair (21.5 ± 9.0 Nm) and plate repair (18.2 ± 1.6 Nm) were not significantly different (n.s.) but were significantly less than the intact group (P < 0.05). Failure torque following IM device removal (30.2 ± 6.5 Nm) was significantly greater than plate removal (12.9 ± 2.0 Nm) (P < 0.05). No significant differences were observed between the intact and IM device removal groups (n.s.).
CONCLUSION: The results of the current study demonstrate that IM and plate devices provide similar repair strength for middle-third clavicle fractures. However, testing of the hardware removal groups found the IM device removal group to be significantly stronger than the plate removal group.

Entities:  

Mesh:

Year:  2013        PMID: 23370985     DOI: 10.1007/s00167-013-2411-5

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  35 in total

1.  The torsional strength of bones with residual screw holes from plates with unicortical and bicortical purchase.

Authors:  A R Remiger; T Miclau; R W Lindsey
Journal:  Clin Biomech (Bristol, Avon)       Date:  1997-01       Impact factor: 2.063

Review 2.  Treatment of clavicle fractures: current concepts review.

Authors:  Olivier A van der Meijden; Trevor R Gaskill; Peter J Millett
Journal:  J Shoulder Elbow Surg       Date:  2011-11-06       Impact factor: 3.019

3.  Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. A multicenter, randomized clinical trial.

Authors: 
Journal:  J Bone Joint Surg Am       Date:  2007-01       Impact factor: 5.284

4.  The effect of screw holes on bone strength.

Authors:  B A Johnson; L M Fallat
Journal:  J Foot Ankle Surg       Date:  1997 Nov-Dec       Impact factor: 1.286

Review 5.  Operative versus nonoperative care of displaced midshaft clavicular fractures: a meta-analysis of randomized clinical trials.

Authors:  Robbin C McKee; Daniel B Whelan; Emil H Schemitsch; Michael D McKee
Journal:  J Bone Joint Surg Am       Date:  2012-04-18       Impact factor: 5.284

6.  Complications of plate fixation in fresh displaced midclavicular fractures.

Authors:  O Böstman; M Manninen; H Pihlajamäki
Journal:  J Trauma       Date:  1997-11

Review 7.  Shaft fractures of the clavicle: current concepts.

Authors:  Vinzenz Smekal; Juergen Oberladstaetter; Peter Struve; Dietmar Krappinger
Journal:  Arch Orthop Trauma Surg       Date:  2008-11-07       Impact factor: 3.067

8.  Clinical and financial comparison of operative and nonoperative treatment of displaced clavicle fractures.

Authors:  Peter L Althausen; Steven Shannon; Minggen Lu; Timothy J O'Mara; Timothy J Bray
Journal:  J Shoulder Elbow Surg       Date:  2012-09-07       Impact factor: 3.019

9.  Primary nonoperative treatment of displaced lateral fractures of the clavicle.

Authors:  C Michael Robinson; David A Cairns
Journal:  J Bone Joint Surg Am       Date:  2004-04       Impact factor: 5.284

Review 10.  Systematic review of the complications of plate fixation of clavicle fractures.

Authors:  Frans-Jasper G Wijdicks; Olivier A J Van der Meijden; Peter J Millett; Egbert J M M Verleisdonk; R Marijn Houwert
Journal:  Arch Orthop Trauma Surg       Date:  2012-01-10       Impact factor: 3.067

View more
  8 in total

Review 1.  [Intramedullary nailing in diaphyseal clavicle fractures using minimally invasive percutaneous reduction].

Authors:  M Müller; T Freude; U Stöckle; T M Kraus
Journal:  Oper Orthop Traumatol       Date:  2017-01-18       Impact factor: 1.154

2.  Treatment of Midshaft Clavicle Fractures: Application of Local Autograft With Concurrent Plate Fixation.

Authors:  Erik L Slette; Jacob D Mikula; Travis Lee Turnbull; Thomas R Hackett
Journal:  Arthrosc Tech       Date:  2016-05-30

3.  Titanium Elastic Nail (TEN) versus Reconstruction Plate Repair of Midshaft Clavicular Fractures: A Finite Element Study.

Authors:  Langqing Zeng; Haifeng Wei; Yanjie Liu; Wen Zhang; Yao Pan; Wei Zhang; Changqing Zhang; Bingfang Zeng; Yunfeng Chen
Journal:  PLoS One       Date:  2015-05-12       Impact factor: 3.240

4.  Meta-analysis of differences in Constant-Murley scores for three mid-shaft clavicular fracture treatments.

Authors:  Wei Jiang; Hua Wang; Yu-Sheng Li; Tian-Jian Zhou; Xin-Jia Hu
Journal:  Oncotarget       Date:  2017-06-12

5.  Single versus dual orthogonal plating for comminuted midshaft clavicle fractures: a biomechanics study.

Authors:  Glenn N Boyce; Andrew J Philpott; David C Ackland; Eugene T Ek
Journal:  J Orthop Surg Res       Date:  2020-07-09       Impact factor: 2.359

6.  Finite element analysis of spiral plate and Herbert screw fixation for treatment of midshaft clavicle fractures.

Authors:  Xiaojuan Zhang; Xiaodong Cheng; Bing Yin; Jianzhao Wang; Sheng Li; Guobin Liu; Zusheng Hu; Weiwei Wu; Yingze Zhang
Journal:  Medicine (Baltimore)       Date:  2019-08       Impact factor: 1.817

7.  Bilaterally Threaded, Minimal Invasive, Elastic Locking Intramedullary Nailing (ELIN) for the Treatment of Clavicle Fractures.

Authors:  Kifayat Ullah; Saima Khan; Yong-Qing Wang; Zhi-Hui Zhao; Peng Cheng; Basanta Sapkota; Liang Ren; Samiullah Khan; Mujeeb Ur Rehman; Yuan Xue
Journal:  Orthop Surg       Date:  2020-02       Impact factor: 2.071

8.  Plate Versus Intramedullary Fixation Care of Displaced Midshaft Clavicular Fractures: A Meta-Analysis of Prospective Randomized Controlled Trials.

Authors:  Xin-Hua Wang; Lin Cheng; Wei-Jun Guo; A-Bing Li; Guang-Jun Cheng; Tao Lei; You-Ming Zhao
Journal:  Medicine (Baltimore)       Date:  2015-10       Impact factor: 1.817

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.