Literature DB >> 21769628

Mechanical evaluation of fourth-generation composite femur hybrid locking plate constructs.

Tarun Goswami1, Vinit Patel, David J Dalstrom, Michael J Prayson.   

Abstract

Locking compression plates are routinely used for open reduction and internal fixation of fractures. Such plates allow for locking or non-locking screw placement in each hole. A combined use of both types of screw application for stabilization of a fracture is commonly applied and referred to as hybrid internal fixation. Locking screws improve the stability of the fixation construct but at the expense of significant additional cost. This study experimentally analyzes various combinations of locking and non-locking screws under simultaneous axial and torsional loading to determine the optimal hybrid locking plate-screw construct in a fourth generation composite femur. Clinically it is necessary to ensure adequate fixation stability in a worse case fracture-bone quality scenario. A locking screw near the fracture gap increased the axial and torsional strength of the locked plate system. Greater removal torque remained in non-locked screws adjacent to locked screws compared to an all non-locking screws control group.

Entities:  

Mesh:

Year:  2011        PMID: 21769628     DOI: 10.1007/s10856-011-4388-2

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  25 in total

Review 1.  Guidelines for the clinical application of the LCP.

Authors:  Emanuel Gautier; Christoph Sommer
Journal:  Injury       Date:  2003-11       Impact factor: 2.586

Review 2.  Development of the Locking Compression Plate.

Authors:  Robert Frigg
Journal:  Injury       Date:  2003-11       Impact factor: 2.586

3.  Mechanical tests and finite element models for bone holding power of tibial locking screws.

Authors:  Sheng-Mou Hou; Ching-Chi Hsu; Jaw-Lin Wang; Ching-Kong Chao; Jinn Lin
Journal:  Clin Biomech (Bristol, Avon)       Date:  2004-08       Impact factor: 2.063

4.  Fixation of osteoporotic distal fibula fractures: A biomechanical comparison of locking versus conventional plates.

Authors:  Todd Kim; Ugur M Ayturk; Andrew Haskell; Theodore Miclau; Christian M Puttlitz
Journal:  J Foot Ankle Surg       Date:  2007 Jan-Feb       Impact factor: 1.286

Review 5.  Principles and clinical application of the locking compression plate (LCP).

Authors:  P Niemeyer; N P Südkamp
Journal:  Acta Chir Orthop Traumatol Cech       Date:  2006-08       Impact factor: 0.531

6.  Locking compression plating: a new solution for fractures in rheumatoid patients.

Authors:  Cong-Feng Luo
Journal:  Mod Rheumatol       Date:  2005       Impact factor: 3.023

7.  In vitro biomechanical comparison of limited contat dynamic compression plate and locking compression plate.

Authors:  A Z Aguila; J M Manos; A S Orlansky; R J Todhunter; E J Trotter; M C H Van der Meulen
Journal:  Vet Comp Orthop Traumatol       Date:  2005       Impact factor: 1.358

8.  Biomechanical testing of the locking compression plate: when does the distance between bone and implant significantly reduce construct stability?

Authors:  M Ahmad; R Nanda; A S Bajwa; J Candal-Couto; S Green; A C Hui
Journal:  Injury       Date:  2007-02-12       Impact factor: 2.586

Review 9.  Innovations in locking plate technology.

Authors:  George J Haidukewych
Journal:  J Am Acad Orthop Surg       Date:  2004 Jul-Aug       Impact factor: 3.020

10.  Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?

Authors:  Karl Stoffel; Ulrich Dieter; Gwidon Stachowiak; André Gächter; Markus S Kuster
Journal:  Injury       Date:  2003-11       Impact factor: 2.586

View more
  3 in total

1.  Effect of plate working length on plate stiffness and cyclic fatigue life in a cadaveric femoral fracture gap model stabilized with a 12-hole 2.4 mm locking compression plate.

Authors:  Peini Chao; Bryan P Conrad; Daniel D Lewis; MaryBeth Horodyski; Antonio Pozzi
Journal:  BMC Vet Res       Date:  2013-06-24       Impact factor: 2.741

2.  Biomechanical Evaluation of Recurrent Dissociation of Modular Humeral Prostheses.

Authors:  Daniel B Luckenbill; Mike F Iossi; Alyssa M George Whitney; Danielle Miller; Lynn A Crosby; Tarun Goswami
Journal:  Bioengineering (Basel)       Date:  2022-02-16

3.  Biomechanical Behavior of a Variable Angle Locked Tibiotalocalcaneal Construct.

Authors:  Farah Hamandi; Gerard Simon; Richard Laughlin; Tarun Goswami
Journal:  Bioengineering (Basel)       Date:  2020-03-14
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.