Literature DB >> 20044692

A comparison of four systems for calibration when templating for total hip replacement with digital radiography.

M Franken1, B Grimm, I Heyligers.   

Abstract

We have investigated the accuracy of the templating of digital radiographs in planning total hip replacement using two common object-based calibration methods with the ball placed laterally (method 1) or medially (method 2) and compared them with two non-object-based methods. The latter comprised the application of a fixed magnification of 121% (method 3) and calculation of magnification based on the object-film-distance (method 4). We studied the post-operative radiographs of 57 patients (19 men, 38 women, mean age 73 years (53 to 89)) using the measured diameter of the prosthetic femoral head and comparing it with the true value. Both object-based methods (1 and 2) produced large errors (mean/maximum: 2.55%/17.4% and 2.04%/6.46%, respectively). Method 3 applying a fixed magnification and method 4 (object-film-distance) produced smaller errors (mean/maximum 1.42%/5.22% and 1.57%/4.24%, respectively; p < 0.01). The latter results were clinically relevant and acceptable when planning was allowed to within one implant size. Object-based calibration (methods 1 and 2) has fundamental problems with the correct placement of the calibration ball. The accuracy of the fixed magnification (method 3) matched that of object-film-distance (method 4) and was the most reliable and efficient calibration method in digital templating.

Entities:  

Mesh:

Year:  2010        PMID: 20044692     DOI: 10.1302/0301-620X.92B1.22257

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  19 in total

1.  [Implant position of total hip arthroplasty shafts. Establishment of a new method for comparison between planned and achieved shaft positions].

Authors:  A Fottner; A Steinbrück; E Volkmer; F Haasters; F Mazoochian; V Jansson
Journal:  Orthopade       Date:  2012-07       Impact factor: 1.087

2.  Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty.

Authors:  Daniel Hernandez-Vaquero; Ferran Abat; Juan Sarasquete; Juan Carlos Monllau
Journal:  World J Orthop       Date:  2013-10-18

3.  Dual-position calibration markers for total hip arthroplasty: theoretical comparison to fixed calibration and single marker method.

Authors:  Christoph Kolja Boese; Sebastian Wilhelm; Stefan Haneder; Philipp Lechler; Peer Eysel; Jan Bredow
Journal:  Int Orthop       Date:  2018-06-20       Impact factor: 3.075

4.  Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty.

Authors:  Mina Derias; Muhammad A Khan; Jamie Buchanan
Journal:  Eur J Trauma Emerg Surg       Date:  2018-09-12       Impact factor: 3.693

5.  Magnification error in digital radiographs of the cervical spine against magnetic resonance imaging measurements.

Authors:  Hideki Shigematsu; Munehisa Koizumi; Masana Yoneda; Jin Iida; Takuya Oshima; Yasuhito Tanaka
Journal:  Asian Spine J       Date:  2013-11-28

6.  [Templating and radiological outcome monitoring for elective total hip arthroplasty. Applied quality management principles for safe patient care].

Authors:  S Kirschner; C Hamann; S Handreka; K P Günther; A Hartmann
Journal:  Unfallchirurg       Date:  2011-09       Impact factor: 1.000

7.  Digital templating in hip hemiarthroplasty: Is it possible to accurately predict femoral head size from magnification alone?

Authors:  Daniel Thurston; Saad El-Ashry; Sreenadh Gella; Kanthan Theivendran
Journal:  J Clin Orthop Trauma       Date:  2022-07-16

8.  The accuracy of external calibration markers in digital templating using the double marker and single marker method: a comparative study.

Authors:  Y Warschawski; I Shichman; S Morgan; O Shaked; S Garceau; N Amzallag; N Snir; A Gold
Journal:  Arch Orthop Trauma Surg       Date:  2020-08-13       Impact factor: 3.067

9.  Use of Acetate Templates Over Digital Radiographs for Templating in Total Hip Arthroplasty: Technique and Its Validation.

Authors:  Tarun Goyal; Siddharth S Sethy; Sajid Ansari; Lakshmana Das; Souvik Paul
Journal:  Indian J Orthop       Date:  2020-11-03       Impact factor: 1.251

10.  Precision and accuracy of pre-surgical planning of non-cemented total hip replacement with calibrated digital images and acetates.

Authors:  Luis Fernando Useche Gómez; Hernando Gaitán-Lee; María Alejandra Duarte; Patrick Dennis Halley; Alejandro Romero Jaramillo; Efraim Leal García
Journal:  J Orthop Surg Res       Date:  2021-07-03       Impact factor: 2.359

View more