Literature DB >> 20041386

A new radiographic method of measuring femoral offset. The Sundsvall method.

Martin Kjellberg1, Erling Englund, Arkan S Sayed-Noor.   

Abstract

Restoring femoral offset (FO) is an important factor for the success of total hip arthroplasty (THA). However, earlier methods of measuring FO do not take in consideration the positioning of the acetabular component. In this study we introduce and evaluate a new radiological method of measuring FO as the horizontal distance between the femoral axis and the midline of the pelvis, at the height of the lateral tip of the greater trochanter.Ten patients operated with THA underwent a plain radiographic examination of the pelvis (AP view) and a CT scanogram for the pelvis and lower limbs (scout view). The radiological FO measurement using the new method was initially compared to FO measurement on CT scanogram and subsequently to the traditional radiological method of measuring FO. We tested the interobserver reliability and the intraobserver reproducibility of the new method.We found an excellent agreement between the new radiological method and the CT measurement and between the new radiological method and the traditional radiological method. We also found an excellent interobserver reliability and an intraobserver reproducibility of the new method. We believe the new method is easier than and as reliable as previously described methods.

Entities:  

Mesh:

Year:  2009        PMID: 20041386     DOI: 10.1177/112070000901900413

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  8 in total

1.  Unstable hip arthroplasties. A prospective cohort study on seventy dislocating hips followed up for four years.

Authors:  Olle Wallner; André Stark; Olle Muren; Thomas Eisler; Olof Sköldenberg
Journal:  Int Orthop       Date:  2014-11-13       Impact factor: 3.075

2.  Validity, reliability and reproducibility of plain radiographic measurements after total hip arthroplasty.

Authors:  Sarwar S Mahmood; Bariq Al-Amiry; Sebastian S Mukka; Saida Baea; Arkan S Sayed-Noor
Journal:  Skeletal Radiol       Date:  2014-11-18       Impact factor: 2.199

3.  Dislocation of bipolar hip hemiarthroplasty through a postero-lateral approach for femoral neck fractures: A cohort study.

Authors:  Sebastian Mukka; Jenny Lindqvist; Sara Peyda; Cyrus Brodén; Sarwar Mahmood; Hamid Hassany; Arkan Sayed-Noor
Journal:  Int Orthop       Date:  2015-01-06       Impact factor: 3.075

4.  [A new measurement method of offset in total hip arthroplasty].

Authors:  Wanming Qu; Hongbin Zhou; Peng Tian; Xiaorong Qin; You Zhang; Wenbin Shen
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-04-15

5.  Pre- and postoperative offset and femoral neck version measurements and validation using 3D computed tomography in total hip arthroplasty.

Authors:  Mats Geijer; Sverrir Kiernan; Martin Sundberg; Gunnar Flivik
Journal:  Acta Radiol Open       Date:  2020-10-08

6.  Femoral neck preservation with a short hip stem produced with powder manufacturing: mid-term results of a consecutive case series.

Authors:  Marco Schiraldi; Manuel Bondi; Lodovico Renzi Brivio
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-01-28

7.  Association between changes in global femoral offset after total hip arthroplasty and function, quality of life, and abductor muscle strength. A prospective cohort study of 222 patients.

Authors:  Sarwar S Mahmood; Sebastian S Mukka; Sead Crnalic; Per Wretenberg; Arkan S Sayed-Noor
Journal:  Acta Orthop       Date:  2015-10-16       Impact factor: 3.717

8.  Cementless Total Hip Arthroplasty in Patients with Osteoarthrosis Secondary to Legg-Calvé-Perthes Disease Compared with Primary Osteoarthrosis: A Case-control Study.

Authors:  Dennis Sansanovicz; Alberto Tesconi Croci; José Ricardo Negreiros Vicente; Leandro Ejnisman; Helder de Souza Miyahara; Henrique de Melo Campos Gurgel
Journal:  Rev Bras Ortop (Sao Paulo)       Date:  2021-10-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.