Literature DB >> 20033594

Towards image guided robotic surgery: multi-arm tracking through hybrid localization.

David Morgan Kwartowitz1, Michael I Miga, S Duke Herrell, Robert L Galloway.   

Abstract

OBJECTIVE: Use of the robotic assisted surgery has been increasing in recent years, due both the continuous increase in the number of applications and the clinical benefits that surgical robots can provide. Currently robotic assisted surgery relies on endoscopic video for navigation, providing only surface visualization, thus limiting subsurface vision. To be able to visualize and identify subsurface information, techniques in image-guidance can be used. As part of designing an image guidance system, all arms of the robot need to be co-localized in a common coordinate system.
METHODS: In order to track multiple arms in a common coordinate space, intrinsic and extrinsic tracking methods can be used. First, the intrinsic tracking of the daVinci, specifically of the setup joints is analyzed. Because of the inadequacy of the setup joints for co-localization a hybrid tracking method is designed and implemented to mitigate the inaccuracy of the setup joints. Different both optical and magnetic tracking methods are examined for setup joint localization.
RESULTS: The hybrid localization method improved the localization accuracy of the setup joints. The inter-arm accuracy in hybrid localization was improved to 3.02 mm. This inter-arm error value was shown to be further reduced when the arms are co-registered, thus reducing common error.

Mesh:

Year:  2009        PMID: 20033594     DOI: 10.1007/s11548-009-0294-1

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  11 in total

1.  Quantitative analysis of factors affecting intraoperative precision and stability of optoelectronic and electromagnetic tracking systems.

Authors:  A Wagner; K Schicho; W Birkfellner; M Figl; R Seemann; F König; Franz Kainberger; R Ewers
Journal:  Med Phys       Date:  2002-05       Impact factor: 4.071

2.  Accuracy assessment protocols for electromagnetic tracking systems.

Authors:  D D Frantz; A D Wiles; S E Leis; S R Kirsch
Journal:  Phys Med Biol       Date:  2003-07-21       Impact factor: 3.609

3.  Design and implementation of a PC-based image-guided surgical system.

Authors:  James D Stefansic; W Andrew Bass; Steven L Hartmann; Ryan A Beasley; Tuhin K Sinha; David M Cash; Alan J Herline; Robert L Galloway
Journal:  Comput Methods Programs Biomed       Date:  2002-11       Impact factor: 5.428

Review 4.  The PAKY, HERMES, AESOP, ZEUS, and da Vinci robotic systems.

Authors:  Hyung L Kim; Peter Schulam
Journal:  Urol Clin North Am       Date:  2004-11       Impact factor: 2.241

Review 5.  Robotics in surgery.

Authors:  Michael D Diodato; Sunil M Prosad; Mary E Klingensmith; Ralph J Damiano
Journal:  Curr Probl Surg       Date:  2004-09       Impact factor: 1.909

6.  Determining the presence of bias error using statistical methods.

Authors:  David M Kwartowitz; Robert L Galloway; Richard G Shiavi
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-01

7.  Predicting error in rigid-body point-based registration.

Authors:  J M Fitzpatrick; J B West; C R Maurer
Journal:  IEEE Trans Med Imaging       Date:  1998-10       Impact factor: 10.048

8.  Accuracy of a two-sensor sonic digitizer.

Authors:  I I Rosen; R G Lane; C A Kelsey
Journal:  Med Phys       Date:  1979 Nov-Dec       Impact factor: 4.071

9.  Systematic distortions in magnetic position digitizers.

Authors:  W Birkfellner; F Watzinger; F Wanschitz; G Enislidis; C Kollmann; D Rafolt; R Nowotny; R Ewers; H Bergmann
Journal:  Med Phys       Date:  1998-11       Impact factor: 4.071

Review 10.  Importance of surgical margins in the management of renal cell carcinoma.

Authors:  John S Lam; Jonathan Bergman; Alberto Breda; Peter G Schulam
Journal:  Nat Clin Pract Urol       Date:  2008-05-13
View more
  6 in total

1.  Toward real-time remote processing of laparoscopic video.

Authors:  Zahra Ronaghi; Edward B Duffy; David M Kwartowitz
Journal:  J Med Imaging (Bellingham)       Date:  2015-12-14

2.  Clinical application of image-enhanced minimally invasive robotic surgery for gastric cancer: a prospective observational study.

Authors:  Yoo Min Kim; Song-Ee Baek; Joon Seok Lim; Woo Jin Hyung
Journal:  J Gastrointest Surg       Date:  2012-12-01       Impact factor: 3.452

3.  Image Compositing for Segmentation of Surgical Tools Without Manual Annotations.

Authors:  Luis C Garcia-Peraza-Herrera; Lucas Fidon; Claudia D'Ettorre; Danail Stoyanov; Tom Vercauteren; Sebastien Ourselin
Journal:  IEEE Trans Med Imaging       Date:  2021-04-30       Impact factor: 10.048

4.  Toward Practical and Accurate Touch-Based Image Guidance for Robotic Partial Nephrectomy.

Authors:  James M Ferguson; E Bryn Pitt; Andria A Remirez; Michael A Siebold; Alan Kuntz; Nicholas L Kavoussi; Eric J Barth; S Duke Herrell; Robert J Webster
Journal:  IEEE Trans Med Robot Bionics       Date:  2020-05-01

5.  Comparing the accuracy of the da Vinci Xi and da Vinci Si for image guidance and automation.

Authors:  James M Ferguson; Bryn Pitt; Alan Kuntz; Josephine Granna; Nicholas L Kavoussi; Naren Nimmagadda; Eric J Barth; Stanley Duke Herrell; Robert J Webster
Journal:  Int J Med Robot       Date:  2020-09-01       Impact factor: 2.483

6.  Real-Time Multi-Modal Sensing and Feedback for Catheterization in Porcine Tissue.

Authors:  Christoff M Heunis; Filip S Uligoj; Carlos Fambuena Santos; Sarthak Misra
Journal:  Sensors (Basel)       Date:  2021-01-03       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.