Literature DB >> 12894982

Accuracy assessment protocols for electromagnetic tracking systems.

D D Frantz1, A D Wiles, S E Leis, S R Kirsch.   

Abstract

Electromagnetic tracking systems have found increasing use in medical applications during the last few years. As with most non-trivial spatial measurement systems, the complex determination of positions and orientations from their underlying raw sensor measurements results in complicated, non-uniform error distributions over the specified measurement volume. This makes it difficult to unambiguously determine accuracy and performance assessments that allow users to judge the suitability of these systems for their particular needs. Various assessment protocols generally emphasize different measurement aspects that typically arise in clinical use. This can easily lead to inconclusive or even contradictory conclusions. We examine some of the major issues involved and discuss three useful calibration protocols. The measurement accuracy of a system can be described in terms of its 'trueness' and its 'precision'. Often, the two are strongly coupled and cannot be easily determined independently. We present a method that allows the two to be disentangled, so that the resultant trueness properly represents the systematic, non-reducible part of the measurement error, and the resultant precision (or repeatability) represents only the statistical, reducible part. Although the discussion is given largely within the context of electromagnetic tracking systems, many of the results are applicable to measurement systems in general.

Mesh:

Year:  2003        PMID: 12894982     DOI: 10.1088/0031-9155/48/14/314

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  27 in total

1.  Epicardial Atrial Ablation Using a Novel Articulated Robotic Medical Probe Via a Percutaneous Subxiphoid Approach.

Authors:  Takeyoshi Ota; Amir Degani; Brett Zubiate; Alon Wolf; Howie Choset; David Schwartzman; Marco A Zenati
Journal:  Innovations (Phila)       Date:  2006

2.  Electromagnetic tracking in the clinical environment.

Authors:  Ziv Yaniv; Emmanuel Wilson; David Lindisch; Kevin Cleary
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

3.  Towards image guided robotic surgery: multi-arm tracking through hybrid localization.

Authors:  David Morgan Kwartowitz; Michael I Miga; S Duke Herrell; Robert L Galloway
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-03-19       Impact factor: 2.924

Review 4.  Navigated laparoscopic ultrasound in abdominal soft tissue surgery: technological overview and perspectives.

Authors:  Thomas Langø; Sinara Vijayan; Anna Rethy; Cecilie Våpenstad; Ole Vegard Solberg; Ronald Mårvik; Gjermund Johnsen; Toril N Hernes
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-09-03       Impact factor: 2.924

5.  Accuracy assessment for the co-registration between optical and VIVE head-mounted display tracking.

Authors:  Leah A Groves; Patrick Carnahan; Daniel R Allen; Rankin Adam; Terry M Peters; Elvis C S Chen
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-05-08       Impact factor: 2.924

6.  A software solution to dynamically reduce metallic distortions of electromagnetic tracking systems for image-guided surgery.

Authors:  Mengfei Li; Christian Hansen; Georg Rose
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-03-03       Impact factor: 2.924

7.  A pilot study on magnetic navigation for transcatheter aortic valve implantation using dynamic aortic model and US image guidance.

Authors:  Zhe Luo; Junfeng Cai; Lixu Gu
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-01-11       Impact factor: 2.924

8.  No difference in accuracy between pinless and conventional computer-assisted surgery in total knee arthroplasty.

Authors:  C Baier; G Maderbacher; H R Springorum; F Zeman; W Fitz; J Schaumburger; J Grifka; J Beckmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-01       Impact factor: 4.342

9.  Accuracy considerations in image-guided cardiac interventions: experience and lessons learned.

Authors:  Cristian A Linte; Pencilla Lang; Maryam E Rettmann; Daniel S Cho; David R Holmes; Richard A Robb; Terry M Peters
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-06-14       Impact factor: 2.924

10.  Electromagnetic tracking in surgical and interventional environments: usability study.

Authors:  Elodie Lugez; Hossein Sadjadi; David R Pichora; Randy E Ellis; Selim G Akl; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-09-06       Impact factor: 2.924

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.