Literature DB >> 33401617

Real-Time Multi-Modal Sensing and Feedback for Catheterization in Porcine Tissue.

Christoff M Heunis1, Filip S Uligoj1, Carlos Fambuena Santos1, Sarthak Misra1,2.   

Abstract

OBJECTIVE: In this study, we introduce a multi-modal sensing and feedback framework aimed at assisting clinicians during endovascular surgeries and catheterization procedures. This framework utilizes state-of-the-art imaging and sensing sub-systems to produce a 3D visualization of an endovascular catheter and surrounding vasculature without the need for intra-operative X-rays.
METHODS: The catheterization experiments within this study are conducted inside a porcine limb undergoing motions. A hybrid position-force controller of a robotically-actuated ultrasound (US) transducer for uneven porcine tissue surfaces is introduced. The tissue, vasculature, and catheter are visualized by integrated real-time US images, 3D surface imaging, and Fiber Bragg Grating (FBG) sensors.
RESULTS: During externally-induced limb motions, the vasculature and catheter can be reliably reconstructed at mean accuracies of 1.9±0.3 mm and 0.82±0.21 mm, respectively.
CONCLUSIONS: The conventional use of intra-operative X-ray imaging to visualize instruments and vasculature in the human body can be reduced by employing improved diagnostic technologies that do not operate via ionizing radiation or nephrotoxic contrast agents. SIGNIFICANCE: The presented multi-modal framework enables the radiation-free and accurate reconstruction of significant tissues and instruments involved in catheterization procedures.

Entities:  

Keywords:  image-guided surgery; medical robotics; multi-modal sensing; robotic registration

Mesh:

Year:  2021        PMID: 33401617      PMCID: PMC7795440          DOI: 10.3390/s21010273

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  26 in total

1.  Real-time vessel segmentation and tracking for ultrasound imaging applications.

Authors:  Julian Guerrero; Septimiu E Salcudean; James A McEwen; Bassam A Masri; Savvakis Nicolaou
Journal:  IEEE Trans Med Imaging       Date:  2007-08       Impact factor: 10.048

2.  Towards image guided robotic surgery: multi-arm tracking through hybrid localization.

Authors:  David Morgan Kwartowitz; Michael I Miga; S Duke Herrell; Robert L Galloway
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-03-19       Impact factor: 2.924

3.  A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery.

Authors:  Y S Kwoh; J Hou; E A Jonckheere; S Hayati
Journal:  IEEE Trans Biomed Eng       Date:  1988-02       Impact factor: 4.538

4.  A deflectable guiding catheter for real-time MRI-guided interventions.

Authors:  Jamie A Bell; Christina E Saikus; Kanishka Ratnayaka; Vincent Wu; Merdim Sonmez; Anthony Z Faranesh; Jessica H Colyer; Robert J Lederman; Ozgur Kocaturk
Journal:  J Magn Reson Imaging       Date:  2011-11-29       Impact factor: 4.813

5.  Association of incident cardiovascular disease with periodic limb movements during sleep in older men: outcomes of sleep disorders in older men (MrOS) study.

Authors:  Brian B Koo; Terri Blackwell; Sonia Ancoli-Israel; Katie L Stone; Marcia L Stefanick; Susan Redline
Journal:  Circulation       Date:  2011-08-22       Impact factor: 29.690

6.  Demonstration of the Safety and Feasibility of Robotically Assisted Percutaneous Coronary Intervention in Complex Coronary Lesions: Results of the CORA-PCI Study (Complex Robotically Assisted Percutaneous Coronary Intervention).

Authors:  Ehtisham Mahmud; Jesse Naghi; Lawrence Ang; Jonathan Harrison; Omid Behnamfar; Ali Pourdjabbar; Ryan Reeves; Mitul Patel
Journal:  JACC Cardiovasc Interv       Date:  2017-07-10       Impact factor: 11.195

7.  Nephrotoxic effects in high-risk patients undergoing angiography.

Authors:  Peter Aspelin; Pierre Aubry; Sven-Göran Fransson; Ruth Strasser; Roland Willenbrock; Knut Joachim Berg
Journal:  N Engl J Med       Date:  2003-02-06       Impact factor: 91.245

8.  Modeling and Validation of the Three-Dimensional Deflection of an MRI-Compatible Magnetically Actuated Steerable Catheter.

Authors:  Taoming Liu; Nate Lombard Poirot; Dominique Franson; Nicole Seiberlich; Mark A Griswold; M Cenk Cavusoglu
Journal:  IEEE Trans Biomed Eng       Date:  2015-12-22       Impact factor: 4.538

9.  An Ex Vivo Evaluation of Tomographic 3-D Ultrasound, B-Mode Ultrasound, CT And MR Imaging to Measure Artery Diameter, Length and Wall Volume.

Authors:  Steven Rogers; Joao Carreira; Ruth Thompson; Ana Morais; Christopher Miller; Wolfgang Wein; Jonathan Ghosh; Charles McCollum
Journal:  Ultrasound Med Biol       Date:  2019-07-30       Impact factor: 2.998

Review 10.  Navigation of guidewires and catheters in the body during intervention procedures: a review of computer-based models.

Authors:  Hoda Sharei; Tanja Alderliesten; John J van den Dobbelsteen; Jenny Dankelman
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-29
View more
  1 in total

Review 1.  Robotics and Artificial Intelligence in Endovascular Neurosurgery.

Authors:  Javier Bravo; Arvin R Wali; Brian R Hirshman; Tilvawala Gopesh; Jeffrey A Steinberg; Bernard Yan; J Scott Pannell; Alexander Norbash; James Friend; Alexander A Khalessi; David Santiago-Dieppa
Journal:  Cureus       Date:  2022-03-30
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.