Literature DB >> 12033587

Quantitative analysis of factors affecting intraoperative precision and stability of optoelectronic and electromagnetic tracking systems.

A Wagner1, K Schicho, W Birkfellner, M Figl, R Seemann, F König, Franz Kainberger, R Ewers.   

Abstract

This study aims to provide a quantitative analysis of the factors affecting the actual precision and stability of optoelectronic and electromagnetic tracking systems in computer-aided surgery under real clinical/intraoperative conditions. A "phantom-skull" with five precisely determined reference distances between marker spheres is used for all measurements. Three optoelectronic and one electromagnetic tracking systems are included in this study. The experimental design is divided into three parts: (1) evaluation of serial- and multislice-CT (computed tomography) images of the phantom-skull for the precision of distance measurements by means of navigation software without a digitizer, (2) digitizer measurements under realistic intraoperative conditions with the factors OR-lamp (radiating into the field of view of the digitizer) or/and "handling with ferromagnetic surgical instruments" (in the field of view of the digitizer) and (3) "point-measurements" to analyze the influence of changes in the angle of inclination of the stylus axis. Deviations between reference distances and measured values are statistically investigated by means of analysis of variance. Computerized measurements of distances based on serial-CT data were more precise than based on multislice-CT data. All tracking systems included in this study proved to be considerably less precise under realistic OR conditions when compared to the technical specifications in the manuals of the systems. Changes in the angle of inclination of the stylus axis resulted in deviations of up to 3.40 mm (mean deviations for all systems ranging from 0.49 to 1.42 mm, variances ranging from 0.09 to 1.44 mm), indicating a strong need for improvements of stylus design. The electromagnetic tracking system investigated in this study was not significantly affected by small ferromagnetic surgical instruments.

Mesh:

Year:  2002        PMID: 12033587     DOI: 10.1118/1.1469625

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  [3-D navigation in the petrous bone with submillimeter accuracy].

Authors:  F Kral; W Freysinger
Journal:  HNO       Date:  2004-08       Impact factor: 1.284

2.  Feasibility of navigated resection of liver tumors using multiplanar visualization of intraoperative 3-dimensional ultrasound data.

Authors:  Siegfried Beller; Michael Hünerbein; Sebastian Eulenstein; Thomas Lange; Peter M Schlag
Journal:  Ann Surg       Date:  2007-08       Impact factor: 12.969

3.  Heterotopic ossification post navigated high tibial osteotomy.

Authors:  Mustafa Citak; Daniel Kendoff; Padhraig F O'Loughlin; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-11-26       Impact factor: 4.342

4.  Towards image guided robotic surgery: multi-arm tracking through hybrid localization.

Authors:  David Morgan Kwartowitz; Michael I Miga; S Duke Herrell; Robert L Galloway
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-03-19       Impact factor: 2.924

5.  Electromagnetic tracking in surgical and interventional environments: usability study.

Authors:  Elodie Lugez; Hossein Sadjadi; David R Pichora; Randy E Ellis; Selim G Akl; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-09-06       Impact factor: 2.924

6.  Minimizing electromagnetic interference from surgical instruments on electromagnetic surgical navigation.

Authors:  Faustin Stevens; Michael A Conditt; Nikhil Kulkarni; Sabir K Ismaily; Philip C Noble; David R Lionberger
Journal:  Clin Orthop Relat Res       Date:  2010-05-29       Impact factor: 4.176

7.  Photoacoustic and fluorescence image-guided surgery using a multifunctional targeted nanoprobe.

Authors:  Lei Xi; Guangyin Zhou; Ning Gao; Lily Yang; David A Gonzalo; Steven J Hughes; Huabei Jiang
Journal:  Ann Surg Oncol       Date:  2014-02-20       Impact factor: 5.344

8.  Accuracy and precision of a method to study kinematics of the temporomandibular joint: combination of motion data and CT imaging.

Authors:  Evre Baltali; Kristin D Zhao; Matthew F Koff; Eugene E Keller; Kai-Nan An
Journal:  J Biomech       Date:  2008-07-09       Impact factor: 2.712

9.  Image-guided surgery and medical robotics in the cranial area.

Authors:  G Widmann
Journal:  Biomed Imaging Interv J       Date:  2007-01-01

Review 10.  Computer-Assisted Orthopedic Surgery: Current State and Future Perspective.

Authors:  Guoyan Zheng; Lutz P Nolte
Journal:  Front Surg       Date:  2015-12-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.