Literature DB >> 12361215

Creation of two tomographic voxel models of paediatric patients in the first year of life.

J C Nipper1, J L Williams, W E Bolch.   

Abstract

Tomographic computational models, based on regional segmentation of CT or MRI medical images, have increasingly been proposed as replacements for current stylized mathematical models of human anatomy used in radiation dosimetry studies. While much effort has been devoted towards the creation of adult models, few research studies have been initiated to address the need for models supporting paediatric radiology dosimetry. In this study, two tomographic models were created using a combination of automatic and manual segmentation via a program created in-house using IDL version 5.5. The first model is of a normal 6 day female newborn, and consists of a 512 x 512 x 485 data array. The CT slices of this model were obtained every 1 mm, and 66 different anatomic regions were defined. The second model is of a patient developmentally equivalent to a 2 month male, and was saved as a 512 x 512 x 438 data array. This subject had severe tissue oedema within the gut, kidneys, liver and spleen. The model is thus considered representative of a critically ill child, from a patient subpopulation expected to receive a larger than normal number of diagnostic x-ray exams. The voxel volumes for the two models are 0.35 mm3 and 0.30 mm3, respectively, thus making these models the most detailed in existence for paediatric dosimetry applications. Ratios of organ masses for the UF newborn model to those within the reference ORNL/MIRD model range from highs of 1.2 to 1.7 for the oesophagus and small intestine/colon, respectively, to lows of 0.18 to 0.27 for the mandible and humeri, respectively. For the UF 2 month model, ratios of organ masses in the UF model to those in the 8 week GSF BABY model ranged from highs of 3.7 to 5.2 for the clavicles and spleen, respectively, to lows of 0.2 to 0.3 for the adrenals and scapulae, respectively.

Entities:  

Mesh:

Year:  2002        PMID: 12361215     DOI: 10.1088/0031-9155/47/17/307

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  An image-based skeletal dosimetry model for the ICRP reference adult male--internal electron sources.

Authors:  Matthew Hough; Perry Johnson; Didier Rajon; Derek Jokisch; Choonsik Lee; Wesley Bolch
Journal:  Phys Med Biol       Date:  2011-03-22       Impact factor: 3.609

Review 2.  Current status and new horizons in Monte Carlo simulation of X-ray CT scanners.

Authors:  Habib Zaidi; Mohammad Reza Ay
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

3.  Development of a paediatric head voxel model database for dosimetric applications.

Authors:  Andreas Stratis; Nathan Touyz; Guozhi Zhang; Reinhilde Jacobs; Ria Bogaerts; Hilde Bosmans
Journal:  Br J Radiol       Date:  2017-07-27       Impact factor: 3.039

Review 4.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

5.  Re-evaluation of pediatric 18F-FDG dosimetry: Cristy-Eckerman versus UF/NCI hybrid computational phantoms.

Authors:  Kitiwat Khamwan; Shannon E O'Reilly; Donika Plyku; Alison Goodkind; Anders Josefsson; Xinhua Cao; Frederic H Fahey; S Ted Treves; Wesley E Bolch; George Sgouros
Journal:  Phys Med Biol       Date:  2018-08-14       Impact factor: 3.609

6.  Development of a high resolution voxelised head phantom for medical physics applications.

Authors:  V Giacometti; S Guatelli; M Bazalova-Carter; A B Rosenfeld; R W Schulte
Journal:  Phys Med       Date:  2017-01-17       Impact factor: 2.685

7.  Internal photon and electron dosimetry of the newborn patient--a hybrid computational phantom study.

Authors:  Michael Wayson; Choonsik Lee; George Sgouros; S Ted Treves; Eric Frey; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2012-03-07       Impact factor: 3.609

8.  The UF family of reference hybrid phantoms for computational radiation dosimetry.

Authors:  Choonsik Lee; Daniel Lodwick; Jorge Hurtado; Deanna Pafundi; Jonathan L Williams; Wesley E Bolch
Journal:  Phys Med Biol       Date:  2009-12-17       Impact factor: 3.609

Review 9.  Voxel-based computational models of real human anatomy: a review.

Authors:  Martin Caon
Journal:  Radiat Environ Biophys       Date:  2004-01-17       Impact factor: 1.925

10.  Patient-specific CT dosimetry calculation: a feasibility study.

Authors:  Thomas Fearon; Huchen Xie; Jason Y Cheng; Holly Ning; Ying Zhuge; Robert W Miller
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.