Literature DB >> 20019107

A prospective trial of 3T and 1.5T time-of-flight and contrast-enhanced MR angiography in the follow-up of coiled intracranial aneurysms.

T J Kaufmann1, J Huston, H J Cloft, J Mandrekar, L Gray, M A Bernstein, J L Atkinson, D F Kallmes.   

Abstract

BACKGROUND AND
PURPOSE: Endovascularly coiled intracranial aneurysms are increasingly being followed up with noninvasive MRA imaging to evaluate for aneurysm recurrences. It has not been well-established which MRA techniques are best for this application, however. Our aim was to prospectively compare 4 MRA techniques, TOF and CE-MRA at 1.5T and 3T, to a reference standard of DSA in the evaluation of previously endovascularly coiled intracranial aneurysms.
MATERIALS AND METHODS: Fifty-eight subjects with 63 previously coiled intracranial aneurysms underwent all 4 MRA techniques within 8 days of DSA. There were 2 outcome variables: coil occlusion class (class 1, complete; class 2, dog ear; class 3, residual neck; class 4, aneurysm filling) and change in degree of occlusion since the previous comparison. Sensitivity and specificity were computed for each MRA technique relative to the reference standard of DSA. Differences among the MRA techniques were evaluated in pair-wise fashion by using the McNemar test.
RESULTS: For the detection of any aneurysm remnant, the sensitivity was 85%-90% for all MRA techniques. Sensitivity dropped to 50%-67% when calculated for the detection of only the class 3 and 4 aneurysm remnants, because several class 3 and 4 remnants were misclassified as class 2 by MRA. CE-MRA at 1.5T and 3T misclassified fewer of the class 3 and 4 remnants than did TOF-MRA at 1.5T, as reflected by the significantly greater sensitivity for larger aneurysm remnants with CE-MRA relative to TOF-MRA at 1.5T (P = .0455 for both comparisons).
CONCLUSIONS: CE-MRA is more likely than TOF-MRA to classify larger aneurysm remnants appropriately. We recommend performing both CE-MRA and TOF-MRA in the follow-up of coiled intracranial aneurysms and at 3T if available.

Entities:  

Mesh:

Year:  2009        PMID: 20019107      PMCID: PMC7964181          DOI: 10.3174/ajnr.A1932

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  33 in total

Review 1.  Imaging artifacts at 3.0T.

Authors:  Matt A Bernstein; John Huston; Heidi A Ward
Journal:  J Magn Reson Imaging       Date:  2006-10       Impact factor: 4.813

2.  Clinical and angiographic outcome of intracranial aneurysms treated with Matrix detachable coils in Chinese patients.

Authors:  George K C Wong; Simon C H Yu; W S Poon
Journal:  Surg Neurol       Date:  2007-02

3.  Evaluation of the occlusion status of coiled intracranial aneurysms with MR angiography at 3T: is contrast enhancement necessary?

Authors:  M E S Sprengers; J D Schaafsma; W J van Rooij; R van den Berg; G J E Rinkel; E M Akkerman; S P Ferns; C B L M Majoie
Journal:  AJNR Am J Neuroradiol       Date:  2009-07-23       Impact factor: 3.825

4.  Time-of-flight MR angiography at 3T versus digital subtraction angiography in the imaging follow-up of 51 intracranial aneurysms treated with coils.

Authors:  Jean-Christophe Ferré; Béatrice Carsin-Nicol; Xavier Morandi; Michel Carsin; Axel de Kersaint-Gilly; Jean-Yves Gauvrit; Hubert-Armand Desal
Journal:  Eur J Radiol       Date:  2008-09-21       Impact factor: 3.528

5.  Endovascular treatment of ophthalmic segment aneurysms with Guglielmi detachable coils.

Authors:  D Roy; J Raymond; A Bouthillier; M W Bojanowski; R Moumdjian; G L'Espérance
Journal:  AJNR Am J Neuroradiol       Date:  1997-08       Impact factor: 3.825

6.  Follow-up of intracranial aneurysms selectively treated with coils: Prospective evaluation of contrast-enhanced MR angiography.

Authors:  L Pierot; C Delcourt; F Bouquigny; D Breidt; B Feuillet; O Lanoix; S Gallas
Journal:  AJNR Am J Neuroradiol       Date:  2006-04       Impact factor: 3.825

7.  Improved image quality of intracranial aneurysms: 3.0-T versus 1.5-T time-of-flight MR angiography.

Authors:  Gordon F Gibbs; John Huston; Matt A Bernstein; Stephen J Riederer; Robert D Brown
Journal:  AJNR Am J Neuroradiol       Date:  2004-01       Impact factor: 3.825

8.  Detachable coil embolisation of ruptured intracranial aneurysms: a single center study, a decade experience.

Authors:  S A Renowden; V Benes; M Bradley; A J Molyneux
Journal:  Clin Neurol Neurosurg       Date:  2008-11-13       Impact factor: 1.876

9.  Three-dimensional time-of-flight MR angiography at 3 T compared to digital subtraction angiography in the follow-up of ruptured and coiled intracranial aneurysms: a prospective study.

Authors:  H Urbach; U Dorenbeck; M von Falkenhausen; K Wilhelm; W Willinek; C Schaller; S Flacke
Journal:  Neuroradiology       Date:  2008-05       Impact factor: 2.804

10.  Three-dimensional time-of-flight (3D TOF) magnetic resonance angiography (MRA) and contrast-enhanced MRA of intracranial aneurysms treated with platinum coils.

Authors:  J Wikström; E Ronne-Engström; G Gal; P Enblad; M Tovi
Journal:  Acta Radiol       Date:  2008-03       Impact factor: 1.990

View more
  26 in total

1.  Use of CT angiography in comparison with other imaging techniques for the determination of embolus and remnant size in experimental aneurysms embolized with hydrogel filaments.

Authors:  M Killer; M R McCoy; M C Vestal; L Weitgasser; G M Cruise
Journal:  AJNR Am J Neuroradiol       Date:  2011-04-21       Impact factor: 3.825

Review 2.  A systematic review of the utility of 1.5 versus 3 Tesla magnetic resonance brain imaging in clinical practice and research.

Authors:  Joanna M Wardlaw; Will Brindle; Ana M Casado; Kirsten Shuler; Moira Henderson; Brenda Thomas; Jennifer Macfarlane; Susana Muñoz Maniega; Katherine Lymer; Zoe Morris; Cyril Pernet; William Nailon; Trevor Ahearn; Abdul Nashirudeen Mumuni; Carlos Mugruza; John McLean; Goultchira Chakirova; Yuehui Terry Tao; Johanna Simpson; Andrew C Stanfield; Harriet Johnston; Jehill Parikh; Natalie A Royle; Janet De Wilde; Mark E Bastin; Nick Weir; Andrew Farrall; Maria C Valdes Hernandez
Journal:  Eur Radiol       Date:  2012-06-09       Impact factor: 5.315

Review 3.  MRA versus DSA for follow-up of coiled intracranial aneurysms: a meta-analysis.

Authors:  M J van Amerongen; H D Boogaarts; J de Vries; A L M Verbeek; F J A Meijer; M Prokop; R H M A Bartels
Journal:  AJNR Am J Neuroradiol       Date:  2013-09-05       Impact factor: 3.825

4.  Autologous adipose-derived mesenchymal stem cells improve healing of coiled experimental saccular aneurysms: an angiographic and histopathological study.

Authors:  Aymeric Rouchaud; Waleed Brinjikji; Daying Dai; Yong-Hong Ding; Tina Gunderson; Dana Schroeder; Laurent Spelle; David F Kallmes; Ramanathan Kadirvel
Journal:  J Neurointerv Surg       Date:  2017-01-11       Impact factor: 5.836

5.  Follow-up assessment of coiled intracranial aneurysms using zTE MRA as compared with TOF MRA: a preliminary image quality study.

Authors:  Song'an Shang; Jing Ye; Xianfu Luo; Jianxun Qu; Yong Zhen; Jingtao Wu
Journal:  Eur Radiol       Date:  2017-04-05       Impact factor: 5.315

Review 6.  Review of 2 decades of aneurysm-recurrence literature, part 2: Managing recurrence after endovascular coiling.

Authors:  E Crobeddu; G Lanzino; D F Kallmes; H J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-15       Impact factor: 3.825

7.  Visualization of Aneurysmal Neck and Dome after Coiling with 3D Multifusion Imaging of Silent MRA and FSE-MR Cisternography.

Authors:  T Satoh; T Hishikawa; M Hiramatsu; K Sugiu; I Date
Journal:  AJNR Am J Neuroradiol       Date:  2019-04-04       Impact factor: 3.825

8.  Intraobserver and interobserver variability in CT angiography and MR angiography measurements of the size of cerebral aneurysms.

Authors:  Hye Jeong Kim; Dae Young Yoon; Eun Soo Kim; Hyung Jin Lee; Hong Jun Jeon; Jong Young Lee; Byung-Moon Cho
Journal:  Neuroradiology       Date:  2017-03-25       Impact factor: 2.804

9.  Pointwise Encoding Time Reduction with Radial Acquisition with Subtraction-Based MRA during the Follow-Up of Stent-Assisted Coil Embolization of Anterior Circulation Aneurysms.

Authors:  Y J Heo; H W Jeong; J W Baek; S T Kim; Y G Jeong; J Y Lee; S-C Jin
Journal:  AJNR Am J Neuroradiol       Date:  2019-04-11       Impact factor: 3.825

10.  New technique: the use of the THRIVE sequence in the follow-up of patients who received endovascular intracranial aneurysm treatment.

Authors:  Emre Mırçık; Bahattin Hakyemez
Journal:  Neuroradiology       Date:  2020-09-11       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.