Literature DB >> 28382536

Follow-up assessment of coiled intracranial aneurysms using zTE MRA as compared with TOF MRA: a preliminary image quality study.

Song'an Shang1, Jing Ye2, Xianfu Luo2, Jianxun Qu3, Yong Zhen4, Jingtao Wu5.   

Abstract

OBJECTIVES: To prospectively assess coiled intracranial aneurysms using a novel non-contrast enhanced zero echo time (zTE) MR angiography (MRA) method, and compare its image quality with time-of-flight (TOF) MRA, using digital subtraction angiography (DSA) as reference.
METHODS: Twenty-five patients (10 males and 15 females; age 53.96 ± 12.46 years) were enrolled in this monocentric study. MRA sequences were performed 24 h before DSA. Susceptibility artefact intensity and flow signal within the parent artery were carried out using a 4-point scale. Occlusion status was assessed using the 3-grade Montreal scale.
RESULTS: Scores of zTE were higher than TOF for both susceptibility artefact intensity (3.42 ± 0.64, 2.92 ± 0.63, P = 0.01) and flow signal (3.66 ± 0.95, 3.24 ± 1.24, P = 0.01). DSA revealed 17 complete occlusions, five residual neck aneurysms and two residual aneurysms. Inter-observer agreement was excellent (weighted κ: 0.89) for zTE and good (weighted κ: 0.68) for TOF. Intermodality agreement was excellent for zTE (weighted κ: 0.95) and good for TOF (weighted κ: 0.80). Correlations of both MRA sequences with DSA were high (zTE, Spearman's ρ: 0.91; TOF, Spearman's ρ: 0.81).
CONCLUSIONS: zTE MRA showed promising results for follow-up assessment of coiled intracranial aneurysms and was superior to TOF MRA for visualizing the parent artery and evaluating occlusion status. KEY POINTS: • Various MRA sequences were applied for follow-up assessment of coiled intracranial aneurysms. • zTE MRA was less sensitive to susceptibility artefacts and haemodynamics. • In this monocentric study, zTE MRA was equivalent to DSA. • zTE MRA maybe an alternative to TOF MRA for follow-up assessment.

Entities:  

Keywords:  Arterial spin labelling; Coiling; DSA; Intracranial aneurysm; MRA

Mesh:

Substances:

Year:  2017        PMID: 28382536     DOI: 10.1007/s00330-017-4794-z

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  35 in total

1.  Carotid artery stents: in vitro comparison of different stent designs and sizes using CT angiography and contrast-enhanced MR angiography at 1.5T and 3T.

Authors:  M Lettau; A Sauer; S Heiland; S Rohde; M Bendszus; S Hähnel
Journal:  AJNR Am J Neuroradiol       Date:  2009-09-12       Impact factor: 3.825

2.  Follow-up of intracranial aneurysms treated by a WEB flow disrupter: a comparative study of DSA and contrast-enhanced MR angiography.

Authors:  Benjamin Mine; Illario Tancredi; Ali Aljishi; Faisal Alghamdi; Margarita Beltran; Maxime Herchuelz; Boris Lubicz
Journal:  J Neurointerv Surg       Date:  2015-05-21       Impact factor: 5.836

3.  Aneurysm Remnants After Coiling and Clipping: Considerations in Surgical and Endovascular Treatment Options.

Authors:  Mandy J Binning; Erol Veznedaroglu
Journal:  Neurosurgery       Date:  2015-08       Impact factor: 4.654

4.  Gadolinium-based Contrast Agent Accumulates in the Brain Even in Subjects without Severe Renal Dysfunction: Evaluation of Autopsy Brain Specimens with Inductively Coupled Plasma Mass Spectroscopy.

Authors:  Tomonori Kanda; Toshio Fukusato; Megumi Matsuda; Keiko Toyoda; Hiroshi Oba; Jun'ichi Kotoku; Takahiro Haruyama; Kazuhiro Kitajima; Shigeru Furui
Journal:  Radiology       Date:  2015-05-05       Impact factor: 11.105

5.  The effectiveness of 3T time-of-flight magnetic resonance angiography for follow-up evaluations after the stent-assisted coil embolization of cerebral aneurysms.

Authors:  Won-Sang Cho; Sam Soo Kim; Seung Jin Lee; Sung Hun Kim
Journal:  Acta Radiol       Date:  2013-09-03       Impact factor: 1.990

6.  Follow-up of intracranial aneurysms treated by flow diverter: comparison of three-dimensional time-of-flight MR angiography (3D-TOF-MRA) and contrast-enhanced MR angiography (CE-MRA) sequences with digital subtraction angiography as the gold standard.

Authors:  Jonathan Attali; Azzedine Benaissa; Sébastien Soize; Krzysztof Kadziolka; Christophe Portefaix; Laurent Pierot
Journal:  J Neurointerv Surg       Date:  2014-10-28       Impact factor: 5.836

7.  Contrast-Enhanced and Time-of-Flight MR Angiographic Assessment of Endovascular Coiled Intracranial Aneurysms at 1.5 T.

Authors:  Akin Levent; Ihsan Yuce; Suat Eren; Omer Ozyigit; Mecit Kantarci
Journal:  Interv Neuroradiol       Date:  2014-12-05       Impact factor: 1.610

8.  Benefits of 3D rotational DSA compared with 2D DSA in the evaluation of intracranial aneurysm.

Authors:  Siong Chuong Wong; Ouzreiah Nawawi; Norlisah Ramli; Khairul Azmi Abd Kadir
Journal:  Acad Radiol       Date:  2012-06       Impact factor: 3.173

9.  International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion.

Authors:  Andrew J Molyneux; Richard S C Kerr; Ly-Mee Yu; Mike Clarke; Mary Sneade; Julia A Yarnold; Peter Sandercock
Journal:  Lancet       Date:  2005 Sep 3-9       Impact factor: 79.321

10.  Optimization of MR Parameters of 3D TOF-MRA for Various Intracranial Stents at 3.0T MRI.

Authors:  Jin Woo Choi; Hong Gee Roh; Won-Jin Moon; Young Il Chun; Chung Hwan Kang
Journal:  Neurointervention       Date:  2011-08-31
View more
  10 in total

1.  Validation of Zero TE-MRA in the Characterization of Cerebrovascular Diseases: A Feasibility Study.

Authors:  S Shang; J Ye; W Dou; X Luo; J Qu; Q Zhu; H Zhang; J Wu
Journal:  AJNR Am J Neuroradiol       Date:  2019-09       Impact factor: 3.825

2.  Visualization of Aneurysmal Neck and Dome after Coiling with 3D Multifusion Imaging of Silent MRA and FSE-MR Cisternography.

Authors:  T Satoh; T Hishikawa; M Hiramatsu; K Sugiu; I Date
Journal:  AJNR Am J Neuroradiol       Date:  2019-04-04       Impact factor: 3.825

3.  Pointwise Encoding Time Reduction with Radial Acquisition with Subtraction-Based MRA during the Follow-Up of Stent-Assisted Coil Embolization of Anterior Circulation Aneurysms.

Authors:  Y J Heo; H W Jeong; J W Baek; S T Kim; Y G Jeong; J Y Lee; S-C Jin
Journal:  AJNR Am J Neuroradiol       Date:  2019-04-11       Impact factor: 3.825

Review 4.  Acute rerupture after coil embolization of ruptured intracranial saccular aneurysms: A literature review.

Authors:  Kailing Li; Yunbao Guo; Ying Zhao; Baofeng Xu; Kan Xu; Jinlu Yu
Journal:  Interv Neuroradiol       Date:  2017-12-12       Impact factor: 1.610

5.  Pointwise encoding time reduction with radial acquisition in subtraction-based magnetic resonance angiography to assess saccular unruptured intracranial aneurysms at 3 Tesla.

Authors:  Qing Fu; Ding-Xi Liu; Xiao-Yong Zhang; Xian-Bo Deng; Chuan-Sheng Zheng
Journal:  Neuroradiology       Date:  2020-08-13       Impact factor: 2.804

6.  Magnetic Resonance Imaging in Aneurysmal Subarachnoid Hemorrhage: Current Evidence and Future Directions.

Authors:  Sarah E Nelson; Haris I Sair; Robert D Stevens
Journal:  Neurocrit Care       Date:  2018-10       Impact factor: 3.210

7.  Intensity of arterial structure acquired by Silent MRA estimates cerebral blood flow.

Authors:  Zhen-An Hwang; Chia-Wei Li; Chien-Yuan Eddy Lin; Jyh-Horng Chen; Chia-Yuen Chen; Wing P Chan
Journal:  Insights Imaging       Date:  2021-12-11

8.  Usefulness of Silent MRA for Evaluation of Aneurysm after Stent-Assisted Coil Embolization.

Authors:  You Na Kim; Jin Wook Choi; Yong Cheol Lim; Jihye Song; Ji Hyun Park; Woo Sang Jung
Journal:  Korean J Radiol       Date:  2022-01-04       Impact factor: 3.500

9.  Usefulness of silent magnetic resonance angiography (MRA) for the diagnosis of atherosclerosis of the internal carotid artery siphon in comparison with time-of-flight MRA.

Authors:  Rui Li; Song Jin; Tao Wu; Xiao Zang; Meng Li; Jinfeng Li
Journal:  Eur J Med Res       Date:  2022-03-21       Impact factor: 2.175

10.  The feasibility of non-contrast-enhanced zero echo time magnetic resonance angiography for characterization of intracranial atherosclerotic disease.

Authors:  Chao Zhang; Weiqiang Dou; Ke Yu; Yun Ji; Wenliang Wang; Muhammad Umair Sami; Yong Shen; Kai Xu
Journal:  Quant Imaging Med Surg       Date:  2021-06
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.