A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner.

R B Slates1, K Farahani, Y Shao, P K Marsden, J Taylor, P E Summers, S Williams, J Beech, S R Cherry.   

Abstract

We have assessed the possibility of artefacts that can arise in attempting to perform simultaneous positron emission tomography (PET) and magnetic resonance imaging (MRI) using a small prototype MR compatible PET scanner (McPET). In these experiments, we examine MR images for any major artefacts or loss in image quality due to inhomogeneities in the magnetic field, radiofrequency interference or susceptibility effects caused by operation of the PET system inside the MR scanner. In addition, possible artefacts in the PET images caused by the static and time-varying magnetic fields or radiofrequency interference from the MR system were investigated. Biological tissue and a T2-weighted spin echo sequence were used to examine susceptibility artefacts due to components of the McPET scanner (scintillator, optical fibres) situated in the MR field of view. A range of commonly used MR pulse sequences was studied while acquiring PET data to look for possible artefacts in either the PET or MR images. Other than a small loss in signal-to-noise using gradient echo sequences, there was no significant interaction between the two imaging systems. Simultaneous PET and MR imaging of simple phantoms was also carried out in different MR systems with field strengths ranging from 0.2 to 4.7 T. The results of these studies demonstrate that it is possible to acquire PET and MR images simultaneously, without any significant artefacts or loss in image quality, using our prototype MR compatible PET scanner.

Mesh:

Year:  1999        PMID: 10473211     DOI: 10.1088/0031-9155/44/8/312

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  21 in total

Review 1.  From PET detectors to PET scanners.

Authors:  John L Humm; Anatoly Rosenfeld; Alberto Del Guerra
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-10-02       Impact factor: 9.236

Review 2.  Impact of technology on the utilisation of positron emission tomography in lymphoma: current and future perspectives.

Authors:  D Visvikis; P J Ell
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-05-13       Impact factor: 9.236

3.  An imaging co-registration system using novel non-invasive and non-radioactive external markers.

Authors:  Tung-Hsin Wu; Jiunn-Kuen Wang; Jason J S Lee; Ren-Shyan Liu; Wan-Yuo Guo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-12       Impact factor: 9.236

4.  Assessment of MR compatibility of a PET insert developed for simultaneous multiparametric PET/MR imaging on an animal system operating at 7 T.

Authors:  Hans F Wehrl; Martin S Judenhofer; Axel Thielscher; Petros Martirosian; Fritz Schick; Bernd J Pichler
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

5.  Progress in multimodality imaging: truly simultaneous ultrasound and magnetic resonance imaging.

Authors:  Laura Curiel; Rajiv Chopra; Kullervo Hynynen
Journal:  IEEE Trans Med Imaging       Date:  2007-12       Impact factor: 10.048

Review 6.  PET/MRI system design.

Authors:  Gaspar Delso; Sibylle Ziegler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

Review 7.  Small animal imaging facility: new perspectives for the radiologist.

Authors:  R Grassi; C Cavaliere; S Cozzolino; L Mansi; S Cirillo; G Tedeschi; R Franchi; P Russo; S Cornacchia; A Rotondo
Journal:  Radiol Med       Date:  2008-12-11       Impact factor: 3.469

Review 8.  Pre-clinical PET/MR: technological advances and new perspectives in biomedical research.

Authors:  Hans F Wehrl; Martin S Judenhofer; Stefan Wiehr; Bernd J Pichler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

Review 9.  Positron emission tomography/magnetic resonance imaging: the next generation of multimodality imaging?

Authors:  Bernd J Pichler; Hans F Wehrl; Armin Kolb; Martin S Judenhofer
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

10.  Studies of the interactions of an MRI system with the shielding in a combined PET/MRI scanner.

Authors:  Bo J Peng; Jeffrey H Walton; Simon R Cherry; Jacob Willig-Onwuachi
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.