A paramagnetic implant containing lithium naphthalocyanine microcrystals for high-resolution biological oximetry.

Guruguhan Meenakshisundaram1, Ramasamy P Pandian, Edward Eteshola, Stephen C Lee, Periannan Kuppusamy.   

Abstract

Lithium naphthalocyanine (LiNc) is a microcrystalline EPR oximetry probe with high sensitivity to oxygen [R.P. Pandian, M. Dolgos, C. Marginean, P.M. Woodward, P.C. Hammel, P.T. Manoharan, P. Kuppusamy, Molecular packing and magnetic properties of lithium naphthalocyanine crystal: hollow channels enabling permeability and paramagnetic sensitivity to molecular oxygen J. Mater. Chem. 19 (2009) 4138-4147]. However, direct implantation of the crystals in the tissue for in vivo oxygen measurements may be hindered by concerns associated with their direct contact with the tissue/cells and loss of EPR signal due to particle migration in the tissue. In order to address these concerns, we have developed encapsulations (chips) of LiNc microcrystals in polydimethyl siloxane (PDMS), an oxygen-permeable, bioinert polymer. Oximetry evaluation of the fabricated chips revealed that the oxygen sensitivity of the crystals was unaffected by encapsulation in PDMS. Chips were stable against sterilization procedures or treatment with common biological oxidoreductants. In vivo oxygen measurements established the ability of the chips to provide reliable and repeated measurements of tissue oxygenation. This study establishes PDMS-encapsulated LiNc as a potential probe for long-term and repeated measurements of tissue oxygenation. Copyright (c) 2009 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20006529      PMCID: PMC2822061          DOI: 10.1016/j.jmr.2009.11.016

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  20 in total

Review 1.  Accurate and sensitive measurements of pO(2) in vivo using low frequency EPR spectroscopy: how to confer biocompatibility to the oxygen sensors.

Authors:  B Gallez; K Mäder
Journal:  Free Radic Biol Med       Date:  2000-12       Impact factor: 7.376

2.  Development and evaluation of biocompatible films of polytetrafluoroethylene polymers holding lithium phthalocyanine crystals for their use in EPR oximetry.

Authors:  M Dinguizli; S Jeumont; N Beghein; J He; T Walczak; P N Lesniewski; H Hou; O Y Grinberg; Artur Sucheta; H M Swartz; B Gallez
Journal:  Biosens Bioelectron       Date:  2005-04-15       Impact factor: 10.618

3.  A naphthalocyanine-based EPR probe for localized measurements of tissue oxygenation.

Authors:  Govindasamy Ilangovan; Ayyakkannu Manivannan; Haiquan Li; Hisao Yanagi; Jay L Zweier; Periannan Kuppusamy
Journal:  Free Radic Biol Med       Date:  2002-01-15       Impact factor: 7.376

4.  Characterization of polydimethylsiloxane (PDMS) properties for biomedical micro/nanosystems.

Authors:  Alvaro Mata; Aaron J Fleischman; Shuvo Roy
Journal:  Biomed Microdevices       Date:  2005-12       Impact factor: 2.838

Review 5.  Oxygen, the lead actor in the pathophysiologic drama: enactment of the trinity of normoxia, hypoxia, and hyperoxia in disease and therapy.

Authors:  Aditi C Kulkarni; Periannan Kuppusamy; Narasimham Parinandi
Journal:  Antioxid Redox Signal       Date:  2007-10       Impact factor: 8.401

6.  Simultaneous measurement of oxygenation in intracellular and extracellular compartments of lung microvascular endothelial cells.

Authors:  Vijay Kumar Kutala; Narasimham L Parinandi; Ramasamy P Pandian; Periannan Kuppusamy
Journal:  Antioxid Redox Signal       Date:  2004-06       Impact factor: 8.401

Review 7.  Using EPR to measure a critical but often unmeasured component of oxidative damage: oxygen.

Authors:  Harold M Swartz
Journal:  Antioxid Redox Signal       Date:  2004-06       Impact factor: 8.401

Review 8.  Peripheral arterial disease in patients with diabetes.

Authors:  Steven P Marso; William R Hiatt
Journal:  J Am Coll Cardiol       Date:  2006-02-09       Impact factor: 24.094

Review 9.  Wounds: an overview of the role of oxygen.

Authors:  Harriet W Hopf; Mark D Rollins
Journal:  Antioxid Redox Signal       Date:  2007-08       Impact factor: 8.401

Review 10.  Detection and characterization of tumor hypoxia using pO2 histography.

Authors:  Peter Vaupel; Michael Höckel; Arnulf Mayer
Journal:  Antioxid Redox Signal       Date:  2007-08       Impact factor: 8.401

View more
  8 in total

Review 1.  In Vivo pO2 Imaging of Tumors: Oxymetry with Very Low-Frequency Electron Paramagnetic Resonance.

Authors:  Boris Epel; Howard J Halpern
Journal:  Methods Enzymol       Date:  2015-09-26       Impact factor: 1.600

2.  A molecular paramagnetic spin-doped biopolymeric oxygen sensor.

Authors:  Guruguhan Meenakshisundaram; Edward Eteshola; Aharon Blank; Stephen C Lee; Periannan Kuppusamy
Journal:  Biosens Bioelectron       Date:  2010-03-15       Impact factor: 10.618

Review 3.  In Vivo Molecular Electron Paramagnetic Resonance-Based Spectroscopy and Imaging of Tumor Microenvironment and Redox Using Functional Paramagnetic Probes.

Authors:  Valery V Khramtsov
Journal:  Antioxid Redox Signal       Date:  2017-12-20       Impact factor: 8.401

4.  Evaluation of a Refined Implantable Resonator for Deep-Tissue EPR Oximetry in the Clinic.

Authors:  Eunice Y Chen; Dan Tse; Huagang Hou; Wilson A Schreiber; Philip E Schaner; Maciej M Kmiec; Kendra A Hebert; Periannan Kuppusamy; Harold M Swartz; Benjamin B Williams
Journal:  Appl Magn Reson       Date:  2021-07-09       Impact factor: 0.974

Review 5.  Clinical EPR: unique opportunities and some challenges.

Authors:  Harold M Swartz; Benjamin B Williams; Bassem I Zaki; Alan C Hartford; Lesley A Jarvis; Eunice Y Chen; Richard J Comi; Marc S Ernstoff; Huagang Hou; Nadeem Khan; Steven G Swarts; Ann B Flood; Periannan Kuppusamy
Journal:  Acad Radiol       Date:  2014-02       Impact factor: 3.173

6.  Transcutaneous oxygen measurement in humans using a paramagnetic skin adhesive film.

Authors:  Maciej M Kmiec; Huagang Hou; M Lakshmi Kuppusamy; Thomas M Drews; Anjali M Prabhat; Sergey V Petryakov; Eugene Demidenko; Philip E Schaner; Jay C Buckey; Aharon Blank; Periannan Kuppusamy
Journal:  Magn Reson Med       Date:  2018-09-11       Impact factor: 4.668

Review 7.  Advances in probes and methods for clinical EPR oximetry.

Authors:  Harold M Swartz; Huagang Hou; Nadeem Khan; Lesley A Jarvis; Eunice Y Chen; Benjamin B Williams; Periannan Kuppusamy
Journal:  Adv Exp Med Biol       Date:  2014       Impact factor: 2.622

Review 8.  The Role of Imaging Biomarkers to Guide Pharmacological Interventions Targeting Tumor Hypoxia.

Authors:  Bernard Gallez
Journal:  Front Pharmacol       Date:  2022-07-15       Impact factor: 5.988

  8 in total