Literature DB >> 16368480

Development and evaluation of biocompatible films of polytetrafluoroethylene polymers holding lithium phthalocyanine crystals for their use in EPR oximetry.

M Dinguizli1, S Jeumont, N Beghein, J He, T Walczak, P N Lesniewski, H Hou, O Y Grinberg, Artur Sucheta, H M Swartz, B Gallez.   

Abstract

Electron paramagnetic resonance (EPR) oximetry is a powerful technology that allows the monitoring of oxygenation in tissues. The measurement of tissue oxygenation can be achieved using lithium phthalocyanine (LiPc) crystals as oxygen reporters. In order to have biocompatibility for the sensing system and to assure long-term stability in the responsiveness of the system, we developed films of Teflon AF 2400 with embedded LiPc crystals. These systems can be used as retrievable inserts or parts of an implantable resonator or catheter. Atomic force microscopy studies revealed that the surface of the films was regular and planar. The response to oxygen of the sensor (EPR linewidth as a function of pO(2)) remained unchanged after implantation in mice, and was not affected by sterilization or irradiation. The use of resonators, holding LiPc embedded in Teflon AF 2400, implanted in the gastrocnemius muscle of rabbits allowed the monitoring of oxygen during several weeks. Several assays also demonstrated the biocompatibility of the system: (1) no hemolytic effect was noted; (2) no toxicity was found using the systemic injection test of extracts; (3) histological analysis in rabbit muscle in which the films were implanted for 1 week or 3 months was similar to standard polyethylene biocompatible devices. These advanced oxygen sensors are promising tools for future pre-clinical and clinical developments of EPR oximetry. These developments can be applied for other applications of biosensors where there is a need for oxygen permeable membranes.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16368480     DOI: 10.1016/j.bios.2005.03.009

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  23 in total

1.  Repeated assessment of orthotopic glioma pO(2) by multi-site EPR oximetry: a technique with the potential to guide therapeutic optimization by repeated measurements of oxygen.

Authors:  Nadeem Khan; Sriram Mupparaju; Huagang Hou; Benjamin B Williams; Harold Swartz
Journal:  J Neurosci Methods       Date:  2011-11-04       Impact factor: 2.390

2.  Two-way communication for programming and measurement in a miniature implantable stimulator.

Authors:  M A Thil; B Gérard; J C Jarvis; J Delbeke
Journal:  Med Biol Eng Comput       Date:  2005-07       Impact factor: 2.602

3.  A highly sensitive biocompatible spin probe for imaging of oxygen concentration in tissues.

Authors:  Anna Bratasz; Aditi C Kulkarni; Periannan Kuppusamy
Journal:  Biophys J       Date:  2007-01-26       Impact factor: 4.033

Review 4.  Clinical EPR: unique opportunities and some challenges.

Authors:  Harold M Swartz; Benjamin B Williams; Bassem I Zaki; Alan C Hartford; Lesley A Jarvis; Eunice Y Chen; Richard J Comi; Marc S Ernstoff; Huagang Hou; Nadeem Khan; Steven G Swarts; Ann B Flood; Periannan Kuppusamy
Journal:  Acad Radiol       Date:  2014-02       Impact factor: 3.173

5.  Dynamic EPR Oximetry of Changes in Intracerebral Oxygen Tension During Induced Thromboembolism.

Authors:  Huagang Hou; Nadeem Khan; Sangeeta Gohain; Clifford J Eskey; Karen L Moodie; Kirk J Maurer; Harold M Swartz; Periannan Kuppusamy
Journal:  Cell Biochem Biophys       Date:  2017-04-22       Impact factor: 2.194

6.  A paramagnetic implant containing lithium naphthalocyanine microcrystals for high-resolution biological oximetry.

Authors:  Guruguhan Meenakshisundaram; Ramasamy P Pandian; Edward Eteshola; Stephen C Lee; Periannan Kuppusamy
Journal:  J Magn Reson       Date:  2009-11-26       Impact factor: 2.229

7.  Skeletal Muscle Oxygenation Measured by EPR Oximetry Using a Highly Sensitive Polymer-Encapsulated Paramagnetic Sensor.

Authors:  H Hou; N Khan; M Nagane; S Gohain; E Y Chen; L A Jarvis; P E Schaner; B B Williams; A B Flood; H M Swartz; P Kuppusamy
Journal:  Adv Exp Med Biol       Date:  2016       Impact factor: 2.622

8.  Direct and Repeated Clinical Measurements of pO2 for Enhancing Cancer Therapy and Other Applications.

Authors:  Harold M Swartz; Benjamin B Williams; Huagang Hou; Nadeem Khan; Lesley A Jarvis; Eunice Y Chen; Philip E Schaner; Arif Ali; Bernard Gallez; Periannan Kuppusamy; Ann B Flood
Journal:  Adv Exp Med Biol       Date:  2016       Impact factor: 2.622

9.  Fabrication and physical evaluation of a polymer-encapsulated paramagnetic probe for biomedical oximetry.

Authors:  Guruguhan Meenakshisundaram; Edward Eteshola; Ramasamy P Pandian; Anna Bratasz; Stephen C Lee; Periannan Kuppusamy
Journal:  Biomed Microdevices       Date:  2009-08       Impact factor: 2.838

10.  An implantable Teflon chip holding lithium naphthalocyanine microcrystals for secure, safe, and repeated measurements of pO2 in tissues.

Authors:  Ramasamy P Pandian; Guruguhan Meenakshisundaram; Anna Bratasz; Edward Eteshola; Stephen C Lee; Periannan Kuppusamy
Journal:  Biomed Microdevices       Date:  2010-06       Impact factor: 2.838

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.