Literature DB >> 11796202

A naphthalocyanine-based EPR probe for localized measurements of tissue oxygenation.

Govindasamy Ilangovan1, Ayyakkannu Manivannan, Haiquan Li, Hisao Yanagi, Jay L Zweier, Periannan Kuppusamy.   

Abstract

A new electron paramagnetic resonance (EPR) oximetry probe, based on a naphthalocyanine macrocycle, is reported to exhibit high oxygen sensitivity and favorable EPR characteristics for biological applications. The free radical probe, lithium naphthalocyanine (LiNc), is synthesized as fine microcrystalline powder with particle size less than 1 microm and high spin density. It exhibits a single sharp EPR peak, whose width varies linearly with oxygen partial pressure (pO2). The EPR spectrum is nonsaturable at typical microwave power levels (< 25 mW at X-band). These unique characteristics make this probe ideal for measuring oxygen concentration in biological tissues, in vivo. The peak-to-peak width under anoxic conditions is 0.51 G (at X-band), and it increases linearly with increase in oxygen partial pressure and reaches 26.0 G for 100% oxygen (760 mmHg), showing an oxygen sensitivity of 34 mG/mmHg. The probe responds to changes in pO2 quickly and reproducibly, thus enabling dynamic measurements of regional oxygenation in real time. The application of this probe for oximetry is demonstrated in an in vivo biological system. The changes in pO2 were monitored in the leg muscle tissue of a living mouse breathing room air and carbogen (95% oxygen + 5% CO2), alternatively. The mean pO2 measured with this probe in muscle tissues was consistent with values reported previously using other methods. Overall, the probe shows very desirable characteristics for localized measurements of tissue oxygenation.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11796202     DOI: 10.1016/s0891-5849(01)00784-5

Source DB:  PubMed          Journal:  Free Radic Biol Med        ISSN: 0891-5849            Impact factor:   7.376


  23 in total

1.  Electron paramagnetic resonance monitoring of ischemia-induced myocardial oxygen depletion and acidosis in isolated rat hearts using soluble paramagnetic probes.

Authors:  Denis A Komarov; Ilirian Dhimitruka; Igor A Kirilyuk; Dmitrii G Trofimiov; Igor A Grigor'ev; Jay L Zweier; Valery V Khramtsov
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

2.  Electron paramagnetic resonance oximetry as a quantitative method to measure cellular respiration: a consideration of oxygen diffusion interference.

Authors:  Tennille Presley; Periannan Kuppusamy; Jay L Zweier; Govindasamy Ilangovan
Journal:  Biophys J       Date:  2006-09-29       Impact factor: 4.033

3.  Evaluation of oxygen-response times of phthalocyanine-based crystalline paramagnetic spin probes for EPR oximetry.

Authors:  Deepti S Vikram; Rizwan Ahmad; Ramasamy P Pandian; Sergey Petryakov; Periannan Kuppusamy
Journal:  J Magn Reson       Date:  2008-04-29       Impact factor: 2.229

4.  Heterogeneity of regional redox status and relation of the redox status to oxygenation in a tumor model, evaluated using electron paramagnetic resonance imaging.

Authors:  Keizo Takeshita; Kumiko Kawaguchi; Kaori Fujii-Aikawa; Megumi Ueno; Shoko Okazaki; Mitsuhiro Ono; Murali C Krishna; Periannan Kuppusamy; Toshihiko Ozawa; Nobuo Ikota
Journal:  Cancer Res       Date:  2010-05-04       Impact factor: 12.701

Review 5.  Theory, instrumentation, and applications of electron paramagnetic resonance oximetry.

Authors:  Rizwan Ahmad; Periannan Kuppusamy
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

Review 6.  Clinical EPR: unique opportunities and some challenges.

Authors:  Harold M Swartz; Benjamin B Williams; Bassem I Zaki; Alan C Hartford; Lesley A Jarvis; Eunice Y Chen; Richard J Comi; Marc S Ernstoff; Huagang Hou; Nadeem Khan; Steven G Swarts; Ann B Flood; Periannan Kuppusamy
Journal:  Acad Radiol       Date:  2014-02       Impact factor: 3.173

7.  A paramagnetic implant containing lithium naphthalocyanine microcrystals for high-resolution biological oximetry.

Authors:  Guruguhan Meenakshisundaram; Ramasamy P Pandian; Edward Eteshola; Stephen C Lee; Periannan Kuppusamy
Journal:  J Magn Reson       Date:  2009-11-26       Impact factor: 2.229

8.  Skeletal Muscle Oxygenation Measured by EPR Oximetry Using a Highly Sensitive Polymer-Encapsulated Paramagnetic Sensor.

Authors:  H Hou; N Khan; M Nagane; S Gohain; E Y Chen; L A Jarvis; P E Schaner; B B Williams; A B Flood; H M Swartz; P Kuppusamy
Journal:  Adv Exp Med Biol       Date:  2016       Impact factor: 2.622

9.  Fabrication and physical evaluation of a polymer-encapsulated paramagnetic probe for biomedical oximetry.

Authors:  Guruguhan Meenakshisundaram; Edward Eteshola; Ramasamy P Pandian; Anna Bratasz; Stephen C Lee; Periannan Kuppusamy
Journal:  Biomed Microdevices       Date:  2009-08       Impact factor: 2.838

10.  Polymer coating of paramagnetic particulates for in vivo oxygen-sensing applications.

Authors:  Edward Eteshola; Ramasamy P Pandian; Stephen C Lee; Periannan Kuppusamy
Journal:  Biomed Microdevices       Date:  2009-04       Impact factor: 2.838