Literature DB >> 19928105

Respiratory motion correction in gated cardiac SPECT using quaternion-based, rigid-body registration.

Jason G Parker1, Bernard A Mair, David R Gilland.   

Abstract

In this article, a new method is introduced for estimating the motion of the heart due to respiration in gated cardiac SPECT using a rigid-body model with rotation parametrized by a unit quaternion. The method is based on minimizing the sum of squared errors between the reference and the deformed frames resulting from the usual optical flow constraint by using an optimized conjugate gradient routine. This method does not require any user-defined parameters or penalty terms, which simplifies its use in a clinical setting. Using a mathematical phantom, the method was quantitatively compared to the principal axis method, as well as an iterative method in which the rotation matrix was represented by Euler angles. The quaternion-based method was shown to be substantially more accurate and robust across a wide range of extramyocardial activity levels than the principal axis method. Compared with the Euler angle representation, the quaternion-based method resulted in similar accuracy but a significant reduction in computation times. Finally, the quaternion-based method was investigated using a respiratory-gated cardiac SPECT acquisition of a human subject. The motion-corrected image has increased sharpness and myocardial uniformity compared to the uncorrected image.

Entities:  

Mesh:

Year:  2009        PMID: 19928105      PMCID: PMC2771716          DOI: 10.1118/1.3215531

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  A study of the motion and deformation of the heart due to respiration.

Authors:  Kate McLeish; Derek L G Hill; David Atkinson; Jane M Blackall; Reza Razavi
Journal:  IEEE Trans Med Imaging       Date:  2002-09       Impact factor: 10.048

2.  Respiratory kinematics of the upper abdominal organs: a quantitative study.

Authors:  H W Korin; R L Ehman; S J Riederer; J P Felmlee; R C Grimm
Journal:  Magn Reson Med       Date:  1992-01       Impact factor: 4.668

3.  A pyramid approach to subpixel registration based on intensity.

Authors:  P Thévenaz; U E Ruttimann; M Unser
Journal:  IEEE Trans Image Process       Date:  1998       Impact factor: 10.856

4.  Estimation of the Rigid-Body Motion from Three-Dimensional Images Using a Generalized Center-of-Mass Points Approach.

Authors:  B Feng; P P Bruyant; P H Pretorius; R D Beach; H C Gifford; J Dey; M Gennert; M A King
Journal:  IEEE Trans Nucl Sci       Date:  2006-10       Impact factor: 1.679

5.  Respiratory motion of the heart: kinematics and the implications for the spatial resolution in coronary imaging.

Authors:  Y Wang; S J Riederer; R L Ehman
Journal:  Magn Reson Med       Date:  1995-05       Impact factor: 4.668

6.  A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT.

Authors:  Wei Lu; Parag J Parikh; James P Hubenschmidt; Jeffrey D Bradley; Daniel A Low
Journal:  Med Phys       Date:  2006-08       Impact factor: 4.071

7.  Correction of heart motion due to respiration in clinical myocardial perfusion SPECT scans using respiratory gating.

Authors:  Gil Kovalski; Ora Israel; Zohar Keidar; Alex Frenkel; Jonathan Sachs; Haim Azhari
Journal:  J Nucl Med       Date:  2007-04       Impact factor: 10.057

8.  Dual cardiac-respiratory gated PET: implementation and results from a feasibility study.

Authors:  Axel Martinez-Möller; Darko Zikic; René M Botnar; Ralph A Bundschuh; William Howe; Sibylle I Ziegler; Nassir Navab; Markus Schwaiger; Stephan G Nekolla
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02-21       Impact factor: 9.236

9.  A Robust Visual Tracking System for Patient Motion Detection in SPECT: Hardware Solutions.

Authors:  Philippe P Bruyant; Michael A Gennert; Glen C Speckert; Richard D Beach; Joel D Morgenstern; Neeru Kumar; Suman Nadella; Michael A King
Journal:  IEEE Trans Nucl Sci       Date:  2005-10       Impact factor: 1.679

10.  Respiratory gating of cardiac PET data in list-mode acquisition.

Authors:  Lefteris Livieratos; Kim Rajappan; Lars Stegger; Klaus Schafers; Dale L Bailey; Paolo G Camici
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-01-17       Impact factor: 9.236

View more
  8 in total

1.  Limited-angle effect compensation for respiratory binned cardiac SPECT.

Authors:  Wenyuan Qi; Yongyi Yang; Miles N Wernick; P Hendrik Pretorius; Michael A King
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

2.  Improving perfusion defect detection with respiratory motion correction in cardiac SPECT at standard and reduced doses.

Authors:  Chao Song; Yongyi Yang; Albert Juan Ramon; Miles N Wernick; P Hendrik Pretorius; Karen L Johnson; Piotr J Slomka; Michael A King
Journal:  J Nucl Cardiol       Date:  2018-07-30       Impact factor: 5.952

3.  End-expiration respiratory gating for a high-resolution stationary cardiac SPECT system.

Authors:  Chung Chan; Mark Harris; Max Le; James Biondi; Yariv Grobshtein; Yi-Hwa Liu; Albert J Sinusas; Chi Liu
Journal:  Phys Med Biol       Date:  2014-09-26       Impact factor: 3.609

4.  Modeling and incorporating cardiac-induced lung tissue motion in a breathing motion model.

Authors:  Benjamin M White; Anand Santhanam; David Thomas; Yugang Min; James M Lamb; Jack Neylon; Shyam Jani; Sergio Gaudio; Subashini Srinivasan; Daniel Ennis; Daniel A Low
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

5.  4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT.

Authors:  Wenyuan Qi; Yongyi Yang; Chao Song; Miles N Wernick; P Hendrik Pretorius; Michael A King
Journal:  IEEE Trans Med Imaging       Date:  2017-04-04       Impact factor: 10.048

6.  Image reconstruction in higher dimensions: myocardial perfusion imaging of tracer dynamics with cardiac motion due to deformation and respiration.

Authors:  Uttam M Shrestha; Youngho Seo; Elias H Botvinick; Grant T Gullberg
Journal:  Phys Med Biol       Date:  2015-10-09       Impact factor: 3.609

Review 7.  An Overview on Image Registration Techniques for Cardiac Diagnosis and Treatment.

Authors:  Azira Khalil; Siew-Cheok Ng; Yih Miin Liew; Khin Wee Lai
Journal:  Cardiol Res Pract       Date:  2018-08-08       Impact factor: 1.866

8.  Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition.

Authors:  Yoonsuk Huh; Uttam M Shrestha; Grant T Gullberg; Youngho Seo
Journal:  Front Cardiovasc Med       Date:  2022-07-13
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.