Modeling and incorporating cardiac-induced lung tissue motion in a breathing motion model.

Benjamin M White1, Anand Santhanam1, David Thomas1, Yugang Min2, James M Lamb1, Jack Neylon1, Shyam Jani1, Sergio Gaudio2, Subashini Srinivasan3, Daniel Ennis4, Daniel A Low1.   

Abstract

PURPOSE: The purpose of this work is to develop a cardiac-induced lung motion model to be integrated into an existing breathing motion model.
METHODS: The authors' proposed cardiac-induced lung motion model represents the lung tissue's specific response to the subject's cardiac cycle. The model is mathematically defined as a product of a converging polynomial function h of the cardiac phase (c) and the maximum displacement y(X0) of each voxel (X0) among all the cardiac phases. The function h(c) was estimated from cardiac-gated MR imaging of ten healthy volunteers using an Akaike Information Criteria optimization algorithm. For each volunteer, a total of 24 short-axis and 18 radial planar views were acquired on a 1.5 T MR scanner during a series of 12-15 s breath-hold maneuvers. Each view contained 30 temporal frames of equal time-duration beginning with the end-diastolic cardiac phase. The frames in each of the planar views were resampled to create a set of three-dimensional (3D) anatomical volumes representing thoracic anatomy at different cardiac phases. A 3D multiresolution optical flow deformable image registration algorithm was used to quantify the difference in tissue position between the end-diastolic cardiac phase and the remaining cardiac phases. To account for image noise, voxel displacements whose maximum values were less than 0.3 mm, were excluded. In addition, the blood vessels were segmented and excluded in order to eliminate registration artifacts caused by blood-flow.
RESULTS: The average cardiac-induced lung motions for displacements greater than 0.3 mm were found to be 0.86 ± 0.74 and 0.97 ± 0.93 mm in the left and right lungs, respectively. The average model residual error for the ten healthy volunteers was found to be 0.29 ± 0.08 mm in the left lung and 0.38 ± 0.14 mm in the right lung for tissue displacements greater than 0.3 mm. The relative error decreased with increasing cardiac-induced lung tissue motion. While the relative error was > 60% for submillimeter cardiac-induced lung tissue motion, the relative error decreased to < 5% for cardiac-induced lung tissue motion that exceeded 10 mm in displacement.
CONCLUSIONS: The authors' studies implied that modeling and including cardiac-induced lung motion would improve breathing motion model accuracy for tissues with cardiac-induced motion greater than 0.3 mm.
© 2014 American Association of Physicists in Medicine.

Mesh:

Year:  2014        PMID: 24694158      PMCID: PMC3987767          DOI: 10.1118/1.4866888

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  29 in total

1.  Construction of a statistical model for cardiac motion analysis using nonrigid image registration.

Authors:  Raghavendra Chandrashekara; Anil Rao; Gerardo Ivar Sanchez-Ortiz; Raad H Mohiaddin; Daniel Rueckert
Journal:  Inf Process Med Imaging       Date:  2003-07

2.  Prediction of respiratory tumour motion for real-time image-guided radiotherapy.

Authors:  Gregory C Sharp; Steve B Jiang; Shinichi Shimizu; Hiroki Shirato
Journal:  Phys Med Biol       Date:  2004-02-07       Impact factor: 3.609

3.  Application of the continuity equation to a breathing motion model.

Authors:  Daniel A Low; Tianyu Zhao; Benjamin White; Deshan Yang; Sasa Mutic; Camille E Noel; Jeffrey D Bradley; Parag J Parikh; Wei Lu
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

4.  In-vivo clinical validation of cardiac deformation and strain measurements from 4D ultrasound.

Authors:  Ming Jack Po; Auranuch Lorsakul; Qi Duan; Kevin J Yeroushalmi; Eiichi Hyodo; Yukiko Oe; Shunichi Homma; Andrew F Laine
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

5.  Deformable models with parameter functions for cardiac motion analysis from tagged MRI data.

Authors:  J Park; D Metaxas; A A Young; L Axel
Journal:  IEEE Trans Med Imaging       Date:  1996       Impact factor: 10.048

6.  Respiratory motion correction in gated cardiac SPECT using quaternion-based, rigid-body registration.

Authors:  Jason G Parker; Bernard A Mair; David R Gilland
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

7.  Distribution of lung tissue hysteresis during free breathing.

Authors:  Benjamin White; Tianyu Zhao; James Lamb; Sara Wuenschel; Jeffrey Bradley; Issam El Naqa; Daniel Low
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

8.  Novel breathing motion model for radiotherapy.

Authors:  Daniel A Low; Parag J Parikh; Wei Lu; James F Dempsey; Sasha H Wahab; James P Hubenschmidt; Michelle M Nystrom; Maureen Handoko; Jeffrey D Bradley
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-11-01       Impact factor: 7.038

9.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

Authors:  Yvette Seppenwoolde; Hiroki Shirato; Kei Kitamura; Shinichi Shimizu; Marcel van Herk; Joos V Lebesque; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-07-15       Impact factor: 7.038

10.  Predicting respiratory motion for four-dimensional radiotherapy.

Authors:  S S Vedam; P J Keall; A Docef; D A Todor; V R Kini; R Mohan
Journal:  Med Phys       Date:  2004-08       Impact factor: 4.071

View more
  2 in total

1.  Bioreactor Development for Lung Tissue Engineering.

Authors:  Angela Panoskaltsis-Mortari
Journal:  Curr Transplant Rep       Date:  2015-03

Review 2.  An Overview on Image Registration Techniques for Cardiac Diagnosis and Treatment.

Authors:  Azira Khalil; Siew-Cheok Ng; Yih Miin Liew; Khin Wee Lai
Journal:  Cardiol Res Pract       Date:  2018-08-08       Impact factor: 1.866

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.