Literature DB >> 19883231

Gamma knife radiosurgery treatment planning for small animals using high-resolution 7T micro-magnetic resonance imaging.

D Wiant1, T F Atwood, J Olson, M Papagikos, M E Forbes, D R Riddle, J D Bourland.   

Abstract

Gamma Knife stereotactic radiosurgery is capable of providing small, high gradient dose distributions to a target with a high level of precision, which makes it an excellent choice for studies of focal irradiations with small animals. However, the Gamma Knife stereotactic radiosurgery process makes use of a human-sized fiducial marker system that requires a field of view of at least 200 mm(2) to relate computed tomography and magnetic resonance images to the Gamma Knife treatment planning software. Thus the Gamma Knife fiducial marker system is five to six times larger than a typical small animal subject. The required large field of view limits the spatial resolution and structural detail available in the animal treatment planning image set. In response to this challenge we have developed a custom-designed stereotactic jig and miniature fiducial marking system that allow small bore high-resolution micro-imaging techniques, such as 7T MR and micro-CT, to be used for treatment planning of Gamma Knife stereotactic radiosurgery focal irradiation of small animals.

Entities:  

Mesh:

Year:  2009        PMID: 19883231      PMCID: PMC2800830          DOI: 10.1667/RR1614.1

Source DB:  PubMed          Journal:  Radiat Res        ISSN: 0033-7587            Impact factor:   2.841


  17 in total

1.  Expression and significance of three types of Fos-immunoreactive cells after gamma knife irradiation of the forebrain in the rat.

Authors:  X Q Duan; S L Wu; T Li; J C Liang; J Y Qiou; Z R Rao; G Ju
Journal:  Neurosci Res       Date:  1999-02       Impact factor: 3.304

Review 2.  Intensity modulated radiation therapy: a review of current practice and future directions.

Authors:  Mona Sanghani; John Mignano
Journal:  Technol Cancer Res Treat       Date:  2006-10

3.  Enhanced magnetic resonance imaging of the rat brain using a stereotactic device with a small head coil: technical note.

Authors:  T Kamiryo; S S Berr; K S Lee; N F Kassell; L Steiner
Journal:  Acta Neurochir (Wien)       Date:  1995       Impact factor: 2.216

4.  The effect of gamma knife irradiation on functions of striatum in rats.

Authors:  Osamu Tokumaru; Mihoko Tomida; Yoko Katayama; Mootohiro Hayashi; Yoriko Kawakami; Nobuo Kouyama
Journal:  J Neurosurg       Date:  2005-01       Impact factor: 5.115

5.  Anticonvulsant effects of gamma surgery in a model of chronic spontaneous limbic epilepsy in rats.

Authors:  Z F Chen; T Kamiryo; S L Henson; H Yamamoto; E H Bertram; F Schottler; F Patel; L Steiner; D Prasad; N F Kassell; S Shareghis; K S Lee
Journal:  J Neurosurg       Date:  2001-02       Impact factor: 5.115

6.  Antiangiogenic agent, thalidomide increases the antitumor effect of single high dose irradiation (gamma knife radiosurgery) in the rat orthotopic glioma model.

Authors:  Jung-Il Lee; Satoshi Itasaka; Ji Tae Kim; Do-Hyun Nam
Journal:  Oncol Rep       Date:  2006-05       Impact factor: 3.906

7.  Expression and changes of HSP70 in the rat forebrain subjected to gamma knife (100Gy) irradiation targeted on the caudate putamen and survived for different times.

Authors:  Z R Rao; X Ge; J Y Qiou; T Yang; L Duan; G Ju
Journal:  Neurosci Res       Date:  2000-10       Impact factor: 3.304

8.  Accuracy of an experimental stereotactic system for MRI-based gamma knife irradiation in the rat.

Authors:  T Kamiryo; S S Berr; H W Berk; K S Lee; N F Kassell; L Steiner
Journal:  Acta Neurochir (Wien)       Date:  1996       Impact factor: 2.216

9.  Metabolite and diffusion changes in the rat brain after Leksell Gamma Knife irradiation.

Authors:  Vít Herynek; Martin Burian; Daniel Jirák; Roman Liscák; Katerina Námestková; Milan Hájek; Eva Syková
Journal:  Magn Reson Med       Date:  2004-08       Impact factor: 4.668

10.  A stereotactic device for experimental gamma knife radiosurgery in rats. A technical note.

Authors:  T Kamiryo; H W Berk; K S Lee; N F Kassell; L Steiner
Journal:  Acta Neurochir (Wien)       Date:  1993       Impact factor: 2.216

View more
  3 in total

1.  Specific issues in small animal dosimetry and irradiator calibration.

Authors:  Terry Yoshizumi; Samuel L Brady; Mike E Robbins; J Daniel Bourland
Journal:  Int J Radiat Biol       Date:  2011-10       Impact factor: 2.694

2.  Development and Validation of a Small Animal Immobilizer and Positioning System for the Study of Delivery of Intracranial and Extracranial Radiotherapy Using the Gamma Knife System.

Authors:  Musaddiq J Awan; Jennifer Dorth; Arvind Mani; Haksoo Kim; Yiran Zheng; Mazen Mislmani; Scott Welford; Jiankui Yuan; Barry W Wessels; Simon S Lo; John Letterio; Mitchell Machtay; Andrew Sloan; Jason W Sohn
Journal:  Technol Cancer Res Treat       Date:  2016-07-26

3.  Functionalization of gadolinium metallofullerenes for detecting atherosclerotic plaque lesions by cardiovascular magnetic resonance.

Authors:  Anthony Dellinger; John Olson; Kerry Link; Stephen Vance; Marinella G Sandros; Jijin Yang; Zhiguo Zhou; Christopher L Kepley
Journal:  J Cardiovasc Magn Reson       Date:  2013-01-16       Impact factor: 5.364

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.