Literature DB >> 8561045

Enhanced magnetic resonance imaging of the rat brain using a stereotactic device with a small head coil: technical note.

T Kamiryo1, S S Berr, K S Lee, N F Kassell, L Steiner.   

Abstract

A stereotactic device (SDM) was developed for performing consistent magnetic resonance imaging (MRI) of the rat brain. The SDM was developed by adapting a radiofrequency transmit/receive head coil of 4.4 cm inner diameter (quadrature birdcage head coil), and utilizing partial acrylic construction for the positioning elements. The small head coil provides improved resolution and accuracy of the image, while the stereotactic holder permits repeatable and accurate imaging of identified brain structures. This system provides several advantages over existing experimental MRI devices. The SDM ensures that the head is always placed in the center of the coil in a uniform fashion. Standardized positioning of the skull optimizes image quality and provides a consistent orientation of the brain. In addition, a widely-utilized coordinate system described by Paxinos and Watson can be employed to assist in the identification of structures and to facilitate surgical planning. The SDM is compatible with a recently-developed stereotactic device for radiosurgery with the Gamma Knife, thus permitting the planning and performance of experimental radiosurgery using the same coordinate system. The SDM also provides the ability to perform MRI and radiosurgery at different times, thus avoiding the need for prolonged anesthesia during an experimental study. Finally, the SDM allows repeated MRI of the same, identifiable positions in the brain during longitudinal experimental studies. The utility of this device is demonstrated here by examining the time course of cerebral damage that evolved within a radiosurgical focus after gamma irradiation.

Entities:  

Mesh:

Year:  1995        PMID: 8561045     DOI: 10.1007/bf01404955

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  15 in total

1.  Brain damage from 125I brachytherapy evaluated by MR imaging, a blood-brain barrier tracer, and light and electron microscopy in a rat model.

Authors:  M Bernstein; T Marotta; P Stewart; J Glen; L Resch; M Henkelman
Journal:  J Neurosurg       Date:  1990-10       Impact factor: 5.115

2.  High-dose single-fraction brain irradiation: MRI, cerebral blood flow, electrophysiological, and histological studies.

Authors:  E H Lo; K A Frankel; G K Steinberg; R L DeLaPaz; J I Fabrikant
Journal:  Int J Radiat Oncol Biol Phys       Date:  1992       Impact factor: 7.038

Review 3.  Xylazine--a review of its pharmacology and use in veterinary medicine.

Authors:  S A Greene; J C Thurmon
Journal:  J Vet Pharmacol Ther       Date:  1988-12       Impact factor: 1.786

4.  Bregma, lambda and the interaural midpoint in stereotaxic surgery with rats of different sex, strain and weight.

Authors:  G Paxinos; C Watson; M Pennisi; A Topple
Journal:  J Neurosci Methods       Date:  1985-04       Impact factor: 2.390

5.  Cerebral radioprotection by pentobarbital: dose-response characteristics and association with GABA agonist activity.

Authors:  J J Olson; R Friedman; K Orr; T Delaney; E H Oldfield
Journal:  J Neurosurg       Date:  1990-05       Impact factor: 5.115

6.  Evaluation of quinolinic acid induced excitotoxic neurodegeneration in rat striatum by quantitative magnetic resonance imaging in vivo.

Authors:  D Sauer; P R Allegrini; K H Thedinga; L Massieu; H Amacker; G E Fagg
Journal:  J Neurosci Methods       Date:  1992-04       Impact factor: 2.390

7.  Use of a clinical MR scanner for imaging the rat brain.

Authors:  D A Smith; L P Clarke; J A Fiedler; F R Murtagh; E A Bonaroti; G J Sengstock; G W Arendash
Journal:  Brain Res Bull       Date:  1993       Impact factor: 4.077

8.  A stereotactic device for experimental gamma knife radiosurgery in rats. A technical note.

Authors:  T Kamiryo; H W Berk; K S Lee; N F Kassell; L Steiner
Journal:  Acta Neurochir (Wien)       Date:  1993       Impact factor: 2.216

9.  Reduction in radiation-induced brain injury by use of pentobarbital or lidocaine protection.

Authors:  E H Oldfield; R Friedman; T Kinsella; R Moquin; J J Olson; K Orr; A M DeLuca
Journal:  J Neurosurg       Date:  1990-05       Impact factor: 5.115

10.  Application of magnetic resonance imaging to the measurement of neurodegeneration in rat brain: MRI data correlate strongly with histology and enzymatic analysis.

Authors:  P R Allegrini; D Sauer
Journal:  Magn Reson Imaging       Date:  1992       Impact factor: 2.546

View more
  6 in total

1.  Gamma knife radiosurgery treatment planning for small animals using high-resolution 7T micro-magnetic resonance imaging.

Authors:  D Wiant; T F Atwood; J Olson; M Papagikos; M E Forbes; D R Riddle; J D Bourland
Journal:  Radiat Res       Date:  2009-11       Impact factor: 2.841

2.  Occlusion of the anterior cerebral artery after Gamma Knife irradiation in a rat.

Authors:  T Kamiryo; M B Lopes; S S Berr; K S Lee; N F Kassell; L Steiner
Journal:  Acta Neurochir (Wien)       Date:  1996       Impact factor: 2.216

3.  Accuracy of an experimental stereotactic system for MRI-based gamma knife irradiation in the rat.

Authors:  T Kamiryo; S S Berr; H W Berk; K S Lee; N F Kassell; L Steiner
Journal:  Acta Neurochir (Wien)       Date:  1996       Impact factor: 2.216

4.  Effects of cardiac pulsation in diffusion tensor imaging of the rat brain.

Authors:  Sungheon Kim; Stephen Pickup; Harish Poptani
Journal:  J Neurosci Methods       Date:  2010-10-14       Impact factor: 2.390

5.  Rapid production of specialized animal handling devices using computer-aided design and solid freeform fabrication.

Authors:  Gabriel P Howles; John C Nouls; Yi Qi; G Allan Johnson
Journal:  J Magn Reson Imaging       Date:  2009-08       Impact factor: 4.813

6.  Imaging of experimental rat gliomas using a clinical MR scanner.

Authors:  Frits Thorsen; Lars Ersland; Håkon Nordli; Per Oyvind Enger; Peter C Huszthy; Arvid Lundervold; Tor Standnes; Rolf Bjerkvig; Morten Lund-Johansen
Journal:  J Neurooncol       Date:  2003-07       Impact factor: 4.130

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.