Literature DB >> 8122542

A stereotactic device for experimental gamma knife radiosurgery in rats. A technical note.

T Kamiryo1, H W Berk, K S Lee, N F Kassell, L Steiner.   

Abstract

A rat stereotactic device was designed for use in Gamma Knife radiosurgery. Experimental radiosurgical lesions were made in superficial and deep cerebral structures to verify the accuracy of the coordinate system, which is based on a standard rat stereotactic atlas. Calculated dosages were shown to be accurate utilizing thermoluminescence dosimetry. Two additional features of the device permit the surgical positioning and placement of electrodes, and postmortem slicing of the brain according to the same coordinate system. This new apparatus allows precise and repeatable gamma irradiation of the rat brain without the need for expensive and time-consuming imaging techniques. Studies of this type will provide a rapid means for examining the effects of radiosurgery on the central nervous system.

Entities:  

Mesh:

Year:  1993        PMID: 8122542     DOI: 10.1007/bf01401844

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  6 in total

1.  The stereotaxic method and radiosurgery of the brain.

Authors:  L LEKSELL
Journal:  Acta Chir Scand       Date:  1951-12-13

2.  Cerebral radiosurgery. II. An anatomical study of gamma radiolesions.

Authors:  J Wennerstrand; U Ungerstedt
Journal:  Acta Chir Scand       Date:  1970

3.  Gammathalamotomy in intractable pain.

Authors:  L Steiner; D Forster; L Leksell; B A Meyerson; J Boëthius
Journal:  Acta Neurochir (Wien)       Date:  1980       Impact factor: 2.216

4.  Bregma, lambda and the interaural midpoint in stereotaxic surgery with rats of different sex, strain and weight.

Authors:  G Paxinos; C Watson; M Pennisi; A Topple
Journal:  J Neurosci Methods       Date:  1985-04       Impact factor: 2.390

5.  Radiobiology of radiosurgery: Part II. The rat C6 glioma model.

Authors:  D Kondziolka; L D Lunsford; D Claassen; S Pandalai; A H Maitz; J C Flickinger
Journal:  Neurosurgery       Date:  1992-08       Impact factor: 4.654

6.  Radiobiology of radiosurgery: Part I. The normal rat brain model.

Authors:  D Kondziolka; L D Lunsford; D Claassen; A H Maitz; J C Flickinger
Journal:  Neurosurgery       Date:  1992-08       Impact factor: 4.654

  6 in total
  5 in total

1.  Gamma knife radiosurgery treatment planning for small animals using high-resolution 7T micro-magnetic resonance imaging.

Authors:  D Wiant; T F Atwood; J Olson; M Papagikos; M E Forbes; D R Riddle; J D Bourland
Journal:  Radiat Res       Date:  2009-11       Impact factor: 2.841

2.  Occlusion of the anterior cerebral artery after Gamma Knife irradiation in a rat.

Authors:  T Kamiryo; M B Lopes; S S Berr; K S Lee; N F Kassell; L Steiner
Journal:  Acta Neurochir (Wien)       Date:  1996       Impact factor: 2.216

3.  Enhanced magnetic resonance imaging of the rat brain using a stereotactic device with a small head coil: technical note.

Authors:  T Kamiryo; S S Berr; K S Lee; N F Kassell; L Steiner
Journal:  Acta Neurochir (Wien)       Date:  1995       Impact factor: 2.216

4.  Accuracy of an experimental stereotactic system for MRI-based gamma knife irradiation in the rat.

Authors:  T Kamiryo; S S Berr; H W Berk; K S Lee; N F Kassell; L Steiner
Journal:  Acta Neurochir (Wien)       Date:  1996       Impact factor: 2.216

5.  Histological changes in the normal rat brain after gamma irradiation.

Authors:  T Kamiryo; N F Kassell; Q A Thai; M B Lopes; K S Lee; L Steiner
Journal:  Acta Neurochir (Wien)       Date:  1996       Impact factor: 2.216

  5 in total