Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops.

Yulong Guan1, David Palanzo, Allen Kunselman, Akif Undar.   

Abstract

An increasing amount of evidence points to cerebral embolization during cardiopulmonary bypass (CPB) as the principal etiologic factor of neurologic complications. In this study, the capability of capturing and classification of gaseous emboli and pressure drop of three different membrane oxygenators (Sorin Apex, Terumo Capiox SX25, Maquet QUADROX) were measured in a simulated adult model of CPB using a novel ultrasound detection and classification quantifier system. The circuit was primed with 1000 mL heparinized human packed red blood cells and 1000 mL lactated Ringer's solution (total volume 2000 mL, corrected hematocrit 26-28%). After the injection of 5 mL air into the venous line, an Emboli Detection and Classification Quantifier was used to simultaneously record microemboli counts at post-pump, post-oxygenator, and post-arterial filter sites. Trials were conducted at normothermic (35 degrees C) and hypothermic (25 degrees C) conditions. Pre-oxygenator and post-oxygenator pressure were recorded in real time and pressure drop was calculated. Maquet QUADROX membrane oxygenator has the lowest pressure drops compared to the other two oxygenators (P < 0.001). The comparison among the three oxygenators indicated better capability of capturing gaseous emboli with the Maquet QUADROX and Terumo Capiox SX25 membrane oxygenator and more emboli may pass through the Sorin Apex membrane oxygenator. Microemboli counts uniformly increased with hypothermic perfusion (25 degrees C). Different types of oxygenators and reservoirs have different capability of capturing gaseous emboli and transmembrane pressure drop. Based on this investigation, Maquet QUADROX membrane oxygenator has the lowest pressure drop and better capability for capturing gaseous microemboli.

Entities:  

Mesh:

Year:  2009        PMID: 19874280     DOI: 10.1111/j.1525-1594.2009.00955.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  7 in total

1.  Evaluation of Quadrox-i adult hollow fiber oxygenator with integrated arterial filter.

Authors:  Antoine P Simons; Patrick W Weerwind
Journal:  J Extra Corpor Technol       Date:  2010-09

2.  Evaluation of Quadrox-i adult hollow fiber oxygenator with integrated arterial filter.

Authors:  Yulong Guan; Xiaowei Su; Robert McCoach; Robert Wise; Allen Kunselman; Akif Undar
Journal:  J Extra Corpor Technol       Date:  2010-06

3.  Use of an extracorporeal circulation perfusion simulator: evaluation of its accuracy and repeatability.

Authors:  Asako Tokumine; Naoki Momose; Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2013-12       Impact factor: 1.731

Review 4.  In Vitro models for thrombogenicity testing of blood-recirculating medical devices.

Authors:  Deepika N Sarode; Shuvo Roy
Journal:  Expert Rev Med Devices       Date:  2019-06-10       Impact factor: 3.166

5.  Can the oxygenator screen filter reduce gaseous microemboli?

Authors:  Daniel Johagen; Micael Appelblad; Staffan Svenmarker
Journal:  J Extra Corpor Technol       Date:  2014-03

6.  Clinical Evaluation of Micro-Embolic Activity with Unexpected Predisposing Factors and Performance of Horizon AF PLUS during Cardiopulmonary Bypass.

Authors:  Ignazio Condello; Roberto Lorusso; Giuseppe Santarpino; Flavio Fiore; Giuseppe Nasso; Giuseppe Speziale
Journal:  Membranes (Basel)       Date:  2022-04-26

7.  In-Vitro Evaluation of Two Types of Neonatal Oxygenators in Handling Gaseous Microemboli and Maintaining Optimal Hemodynamic Stability During Cardiopulmonary Bypass.

Authors:  Neelima Marupudi; Shigang Wang; Luiz Fernando Canêo; Fabio Biscegli Jatene; Allen R Kunselman; Akif Undar
Journal:  Braz J Cardiovasc Surg       Date:  2016 Sep-Oct
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.