Evaluation of Quadrox-i adult hollow fiber oxygenator with integrated arterial filter.

Yulong Guan1, Xiaowei Su, Robert McCoach, Robert Wise, Allen Kunselman, Akif Undar.   

Abstract

Gaseous microemboli (GME) remain a challenge for cardiopulmonary bypass procedures in adult as well as pediatric cardiac surgery patients. The present study tested the effectiveness of a new adult membrane oxygenator in models both with and without an integrated arterial filter to evaluate GME trapping capability and determine membrane pressure drops at various flow rates and temperatures. The experimental circuit included a RotaFlow centrifugal blood pump, Quadrox-i (n = 8) or Quadrox (n = 8) adult microporous membrane oxygenator, and Sorin adult tubing package. A Sorin Cardiovascular VVR 4000i venous reservoir served as pseudo-patient. The circuit was primed with 900 mL heparinized human red blood cells and 300 mL Lactated Ringer's solution. The final hematocrit was 36%. Tests were performed at different flow rates (4 L/min, 5 L/min, and 6 L/min) and temperatures (35 degrees and 30 degrees). Five mL of bolus air was injected into the venous line over 15 seconds using a syringe connected to a 3/8 x 1/2 luer connector. The Quadrox-i adult microporous membrane oxygenator with integrated arterial filter had a similar pressure drop at 4 L/min and 35 degrees C compared with Quadrox membrane oxygenator whereas it had higher pressure drops at 5 L/min and 6 L/min (p < .001). Quadrox-i adult microporous membrane oxygenator reduced the total emboli count and total emboli volume delivered to the pseudo-patient at all flow rates (p < .001).The emboli handling of Quadrox-i adult microporous membrane oxygenator was not affected by flow rate and temperature. Compared with the traditional Quadrox oxygenator, Quadrox-i adult microporous membrane oxygenator with integrated arterial filter and Softline coating has improved GME handling capacity.

Entities:  

Mesh:

Year:  2010        PMID: 20648898      PMCID: PMC4680037     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  9 in total

Review 1.  Vacuum-assisted venous drainage and gaseous microemboli in cardiopulmonary bypass.

Authors:  Shigang Wang; Akif Undar
Journal:  J Extra Corpor Technol       Date:  2008-12

2.  "Stolen" blood flow: effect of an open arterial filter purge line in a simulated neonatal CPB model.

Authors:  Shigang Wang; Akemi Miller; John L Myers; Akif Undar
Journal:  ASAIO J       Date:  2008 Jul-Aug       Impact factor: 2.872

3.  Comparison of two different blood pumps on delivery of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated infant CPB model.

Authors:  Shigang Wang; Allen R Kunselman; John L Myers; Akif Undar
Journal:  ASAIO J       Date:  2008 Sep-Oct       Impact factor: 2.872

4.  Microemboli detection and classification by innovative ultrasound technology during simulated neonatal cardiopulmonary bypass at different flow rates, perfusion modes, and perfusate temperatures.

Authors:  Robert S Schreiner; Alan R Rider; John W Myers; Bingyang Ji; Allen R Kunselman; John L Myers; Akif Undar
Journal:  ASAIO J       Date:  2008 May-Jun       Impact factor: 2.872

5.  Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops.

Authors:  Yulong Guan; David Palanzo; Allen Kunselman; Akif Undar
Journal:  Artif Organs       Date:  2009-10-28       Impact factor: 3.094

Review 6.  Reducing cerebral emboli during cardiopulmonary bypass.

Authors:  Kriengchai Prasongsukarn; Michael A Borger
Journal:  Semin Cardiothorac Vasc Anesth       Date:  2005-06

7.  Use of a dynamic bubble trap in the arterial line reduces microbubbles during cardiopulmonary bypass and microembolic signals in the middle cerebral artery.

Authors:  Mathias Perthel; Samer Kseibi; Andreas Bendisch; Joachim Laas
Journal:  Perfusion       Date:  2005-05       Impact factor: 1.972

Review 8.  Microemboli detection on extracorporeal bypass circuits.

Authors:  J E Lynch; J B Riley
Journal:  Perfusion       Date:  2008-01       Impact factor: 1.972

9.  A new de-airing technique that reduces systemic microemboli during open surgery: a prospective controlled study.

Authors:  Faleh Al-Rashidi; Sten Blomquist; Peter Höglund; Carl Meurling; Anders Roijer; Bansi Koul
Journal:  J Thorac Cardiovasc Surg       Date:  2009-07       Impact factor: 5.209

  9 in total
  3 in total

1.  Evaluation of Quadrox-i adult hollow fiber oxygenator with integrated arterial filter.

Authors:  Antoine P Simons; Patrick W Weerwind
Journal:  J Extra Corpor Technol       Date:  2010-09

2.  The effects of pressure on gases in solution: possible insights to improve microbubble filtration for extracorporeal circulation.

Authors:  Daniel P Herbst
Journal:  J Extra Corpor Technol       Date:  2013-06

3.  Effects of Purge-Flow Rate on Microbubble Capture in Radial Arterial-Line Filters.

Authors:  Daniel P Herbst
Journal:  J Extra Corpor Technol       Date:  2016-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.