Literature DB >> 24022821

Use of an extracorporeal circulation perfusion simulator: evaluation of its accuracy and repeatability.

Asako Tokumine, Naoki Momose, Yasuko Tomizawa.   

Abstract

Medical simulators have mainly been used as educational tools. They have been used to train technicians and to educate potential users about safety. We combined software for hybrid-type extracorporeal circulation simulation (ECCSIM) with a CPB-Workshop console. We evaluated the performance of ECCSIM, including its accuracy and repeatability, during simulated ECC. We performed a detailed evaluation of the synchronization of the software with the console and the function of the built-in valves. An S-III heart–lung machine was used for the open circuit. It included a venous reservoir, an oxygenator (RX-25), and an arterial filter. The tubes for venous drainage and the arterial line were connected directly to the ports of the console. The ECCSIM recorded the liquid level of the reservoir continuously. The valve in the console controlled the pressure load of the arterial line. The software made any adjustments necessary to both arterial pressure load and the venous drainage flow volume. No external flowmeters were necessary during simulation. We found the CPB-Workshop to be convenient, reliable, and sufficiently exact. It can be used to validate procedures by monitoring the controls and responses by using a combination of qualitative measures.

Mesh:

Year:  2013        PMID: 24022821     DOI: 10.1007/s10047-013-0728-y

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  14 in total

1.  Simulation in surgical training: educational issues and practical implications.

Authors:  Roger Kneebone
Journal:  Med Educ       Date:  2003-03       Impact factor: 6.251

2.  Evaluation of basic perfusion techniques, ECCSIM-Lite simulator.

Authors:  Asako Tokumine; Shinji Ninomiya; Megumi Tokaji; Tatsuya Kurosaki; Yasuko Tomizawa
Journal:  J Extra Corpor Technol       Date:  2010-06

3.  Development of a new control device for stabilizing blood level in reservoir during extracorporeal circulation.

Authors:  Naoki Momose; Rie Yamakoshi; Ryo Kokubo; Toru Yasuda; Norio Iwamoto; Chinori Umeda; Itsuro Nakajima; Mitsunobu Yanagisawa; Yasuko Tomizawa
Journal:  Perfusion       Date:  2010-03       Impact factor: 1.972

Review 4.  Simulation-based assessment in anesthesiology: requirements for practical implementation.

Authors:  John R Boulet; David J Murray
Journal:  Anesthesiology       Date:  2010-04       Impact factor: 7.892

5.  "Orpheus" cardiopulmonary bypass simulation system.

Authors:  Richard W Morris; David A Pybus
Journal:  J Extra Corpor Technol       Date:  2007-12

6.  Evaluation of membrane oxygenators and reservoirs in terms of capturing gaseous microemboli and pressure drops.

Authors:  Yulong Guan; David Palanzo; Allen Kunselman; Akif Undar
Journal:  Artif Organs       Date:  2009-10-28       Impact factor: 3.094

7.  Theoretical treatise: arterial pressure during aortic surgery.

Authors:  Tim Ridgway; Omar Al-Rawi; Kenneth Palmer; Mark Pullan; Michael Poullis
Journal:  J Extra Corpor Technol       Date:  2012-09

8.  Evaluation of Capiox FX05 oxygenator with an integrated arterial filter on trapping gaseous microemboli and pressure drop with open and closed purge line.

Authors:  Feng Qiu; Sophia Peng; Allen Kunselman; Akif Ündar
Journal:  Artif Organs       Date:  2010-11       Impact factor: 3.094

9.  Virtual patient simulator for the perfusion resource management drill.

Authors:  Shinji Ninomiya; Megumi Tokaji; Asako Tokumine; Tatsuya Kurosaki
Journal:  J Extra Corpor Technol       Date:  2009-12

10.  Quantitative evaluation of hand cranking a roller pump in a crisis management drill.

Authors:  Yasuko Tomizawa; Asako Tokumine; Shinji Ninomiya; Naoki Momose; Toru Matayoshi
Journal:  J Artif Organs       Date:  2008-10-05       Impact factor: 1.731

View more
  1 in total

Review 1.  Journal of Artificial Organs 2013: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; E Tatsumi; T Tsukiya; K Matsuda; K Fukunaga; A Kishida; T Masuzawa; G Matsumiya; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2014-02-26       Impact factor: 1.731

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.