MRI signal intensity based B-spline nonrigid registration for pre- and intraoperative imaging during prostate brachytherapy.

Sota Oguro1, Junichi Tokuda, Haytham Elhawary, Steven Haker, Ron Kikinis, Clare M C Tempany, Nobuhiko Hata.   

Abstract

PURPOSE: To apply an intensity-based nonrigid registration algorithm to MRI-guided prostate brachytherapy clinical data and to assess its accuracy.
MATERIALS AND METHODS: A nonrigid registration of preoperative MRI to intraoperative MRI images was carried out in 16 cases using a Basis-Spline algorithm in a retrospective manner. The registration was assessed qualitatively by experts' visual inspection and quantitatively by measuring the Dice similarity coefficient (DSC) for total gland (TG), central gland (CG), and peripheral zone (PZ), the mutual information (MI) metric, and the fiducial registration error (FRE) between corresponding anatomical landmarks for both the nonrigid and a rigid registration method.
RESULTS: All 16 cases were successfully registered in less than 5 min. After the nonrigid registration, DSC values for TG, CG, PZ were 0.91, 0.89, 0.79, respectively, the MI metric was -0.19 +/- 0.07 and FRE presented a value of 2.3 +/- 1.8 mm. All the metrics were significantly better than in the case of rigid registration, as determined by one-sided t-tests.
CONCLUSION: The intensity-based nonrigid registration method using clinical data was demonstrated to be feasible and showed statistically improved metrics when compare to only rigid registration. The method is a valuable tool to integrate pre- and intraoperative images for brachytherapy.

Entities:  

Mesh:

Year:  2009        PMID: 19856437      PMCID: PMC2801562          DOI: 10.1002/jmri.21955

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  32 in total

1.  A comparative study of warping and rigid body registration for the prostate and pelvic MR volumes.

Authors:  Baowei Fei; Corey Kemper; David L Wilson
Journal:  Comput Med Imaging Graph       Date:  2003 Jul-Aug       Impact factor: 4.790

2.  MRI-guided prostate brachytherapy with single needle method--a planning study.

Authors:  Marion P R Van Gellekom; Marinus A Moerland; Jan J Battermann; Jan J W Lagendijk
Journal:  Radiother Oncol       Date:  2004-06       Impact factor: 6.280

3.  Deformable image registration for the use of magnetic resonance spectroscopy in prostate treatment planning.

Authors:  Xingen Wu; Steven J Dibiase; Rao Gullapalli; Cedric X Yu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-04-01       Impact factor: 7.038

4.  Superconducting open-configuration MR imaging system for image-guided therapy.

Authors:  J F Schenck; F A Jolesz; P B Roemer; H E Cline; W E Lorensen; R Kikinis; S G Silverman; C J Hardy; W D Barber; E T Laskaris
Journal:  Radiology       Date:  1995-06       Impact factor: 11.105

5.  Evaluation of three-dimensional finite element-based deformable registration of pre- and intraoperative prostate imaging.

Authors:  A Bharatha; M Hirose; N Hata; S K Warfield; M Ferrant; K H Zou; E Suarez-Santana; J Ruiz-Alzola; A D'Amico; R A Cormack; R Kikinis; F A Jolesz; C M Tempany
Journal:  Med Phys       Date:  2001-12       Impact factor: 4.071

6.  MRI/TRUS data fusion for prostate brachytherapy. Preliminary results.

Authors:  Christophe Reynier; Jocelyne Troccaz; Philippe Fourneret; André Dusserre; Cécile Gay-Jeune; Jean-Luc Descotes; Michel Bolla; Jean-Yves Giraud
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

7.  Statistical validation of image segmentation quality based on a spatial overlap index.

Authors:  Kelly H Zou; Simon K Warfield; Aditya Bharatha; Clare M C Tempany; Michael R Kaus; Steven J Haker; William M Wells; Ferenc A Jolesz; Ron Kikinis
Journal:  Acad Radiol       Date:  2004-02       Impact factor: 3.173

8.  Intra- and inter-observer variability in contouring prostate and seminal vesicles: implications for conformal treatment planning.

Authors:  C Fiorino; M Reni; A Bolognesi; G M Cattaneo; R Calandrino
Journal:  Radiother Oncol       Date:  1998-06       Impact factor: 6.280

9.  MR imaging of the prostate gland: normal anatomy.

Authors:  H Hricak; G C Dooms; J E McNeal; A S Mark; M Marotti; A Avallone; M Pelzer; E C Proctor; E A Tanagho
Journal:  AJR Am J Roentgenol       Date:  1987-01       Impact factor: 3.959

10.  Comparison of prostate volume measured by transrectal ultrasonography and MRI with the actual prostate volume measured after radical prostatectomy.

Authors:  Chang Wook Jeong; Hyoung Keun Park; Sung Kyu Hong; Seok-Soo Byun; Hak Jong Lee; Sang Eun Lee
Journal:  Urol Int       Date:  2008-08-29       Impact factor: 2.089

View more
  18 in total

1.  The National Alliance for Medical Image Computing, a roadmap initiative to build a free and open source software infrastructure for translational research in medical image analysis.

Authors:  Tina Kapur; Steve Pieper; Ross Whitaker; Stephen Aylward; Marianna Jakab; Will Schroeder; Ron Kikinis
Journal:  J Am Med Inform Assoc       Date:  2011-11-10       Impact factor: 4.497

2.  Image registration for targeted MRI-guided transperineal prostate biopsy.

Authors:  Andriy Fedorov; Kemal Tuncali; Fiona M Fennessy; Junichi Tokuda; Nobuhiko Hata; William M Wells; Ron Kikinis; Clare M Tempany
Journal:  J Magn Reson Imaging       Date:  2012-05-29       Impact factor: 4.813

3.  PROBABILISTIC NON-RIGID REGISTRATION OF PROSTATE IMAGES: MODELING AND QUANTIFYING UNCERTAINTY.

Authors:  Petter Risholm; Andriy Fedorov; Jennifer Pursley; Kemal Tuncali; Robert Cormack; William M Wells
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2011-06-09

4.  Prostate multimodality image registration based on B-splines and quadrature local energy.

Authors:  Jhimli Mitra; Robert Martí; Arnau Oliver; Xavier Lladó; Soumya Ghose; Joan C Vilanova; Fabrice Meriaudeau
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-06-26       Impact factor: 2.924

5.  Effectiveness of temporal and dynamic subtraction images of the liver for detection of small HCC on abdominal CT images: comparison of 3D nonlinear image-warping and 3D global-matching techniques.

Authors:  Eiichiro Okumura; Shigeru Sanada; Masayuki Suzuki; Akihiro Takemura; Osamu Matsui
Journal:  Radiol Phys Technol       Date:  2011-01-13

6.  Graphics Processing Unit-Accelerated Nonrigid Registration of MR Images to CT Images During CT-Guided Percutaneous Liver Tumor Ablations.

Authors:  Junichi Tokuda; William Plishker; Meysam Torabi; Olutayo I Olubiyi; George Zaki; Servet Tatli; Stuart G Silverman; Raj Shekher; Nobuhiko Hata
Journal:  Acad Radiol       Date:  2015-03-14       Impact factor: 3.173

7.  Minimisation of Signal Intensity Differences in Distortion Correction Approaches of Brain Magnetic Resonance Diffusion Tensor Imaging.

Authors:  Dong-Hoon Lee; Do-Wan Lee; David Henry; Hae-Jin Park; Bong-Soo Han; Dong-Cheol Woo
Journal:  Eur Radiol       Date:  2018-04-12       Impact factor: 5.315

8.  Learning statistical correlation for fast prostate registration in image-guided radiotherapy.

Authors:  Yonghong Shi; Shu Liao; Dinggang Shen
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

9.  Pathologic correlation of transperineal in-bore 3-Tesla magnetic resonance imaging-guided prostate biopsy samples with radical prostatectomy specimen.

Authors:  Erik Velez; Andriy Fedorov; Kemal Tuncali; Olutayo Olubiyi; Christopher B Allard; Adam S Kibel; Clare M Tempany
Journal:  Abdom Radiol (NY)       Date:  2017-08

10.  Accuracy analysis in MRI-guided robotic prostate biopsy.

Authors:  Helen Xu; Andras Lasso; Peter Guion; Axel Krieger; Aradhana Kaushal; Anurag K Singh; Peter A Pinto; Jonathan Coleman; Robert L Grubb; Jean-Baptiste Lattouf; Cynthia Menard; Louis L Whitcomb; Gabor Fichtinger
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-03-27       Impact factor: 2.924

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.