Literature DB >> 21229338

Effectiveness of temporal and dynamic subtraction images of the liver for detection of small HCC on abdominal CT images: comparison of 3D nonlinear image-warping and 3D global-matching techniques.

Eiichiro Okumura1, Shigeru Sanada, Masayuki Suzuki, Akihiro Takemura, Osamu Matsui.   

Abstract

Misregistration errors occur at the periphery of the hepatic region due to respiratory- and interval-related changes in hepatic shape. To reduce these misregistration errors, we developed a temporal and dynamic subtraction technique to enhance small hepatocellular carcinoma (HCC) by using a 3D nonlinear image-warping technique. The study population consisted of 21 patients with HCC. We registered the present and previous arterial-phase CT images or the present nonenhanced and arterial-phase CT images obtained in the same position by 3D global-matching plus 3D nonlinear image-warping. Temporal subtraction images were obtained by subtraction of the previous arterial-phase CT image from the warped present arterial-phase CT image. Dynamic subtraction images were obtained by subtraction of the present nonenhanced CT image from the warped present arterial-phase CT image. When we used this new technique, the number of good or excellent cases increased from 14.2% (3/21 cases) to 71.4% (15/21 cases) on temporal subtraction images. With this technique, subjective rating scores for image quality improved in 57.1% of cases (12/21 cases) on temporal subtraction images and 81.0% of cases (17/21 cases) on dynamic subtraction images. The results indicated that the new subtraction images were greatly improved by use of the 3D nonlinear image-warping technique.

Entities:  

Mesh:

Year:  2011        PMID: 21229338     DOI: 10.1007/s12194-010-0110-1

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  31 in total

1.  Technical note: creating a four-dimensional model of the liver using finite element analysis.

Authors:  K K Brock; S J Hollister; L A Dawson; J M Balter
Journal:  Med Phys       Date:  2002-07       Impact factor: 4.071

2.  Modeling liver motion and deformation during the respiratory cycle using intensity-based nonrigid registration of gated MR images.

Authors:  Torsten Rohlfing; Calvin R Maurer; Walter G O'Dell; Jianhui Zhong
Journal:  Med Phys       Date:  2004-03       Impact factor: 4.071

3.  Evaluation of an automated system for temporal subtraction of thin-section thoracic CT.

Authors:  H Takao; I Doi; M Tateno
Journal:  Br J Radiol       Date:  2006-07-19       Impact factor: 3.039

4.  Improvement of temporal and dynamic subtraction images on abdominal CT using 3D global image matching and nonlinear image warping techniques.

Authors:  E Okumura; S Sanada; M Suzuki; A Takemura; O Matsui
Journal:  Phys Med Biol       Date:  2007-10-16       Impact factor: 3.609

5.  Evaluation of an automated deformable image matching method for quantifying lung motion in respiration-correlated CT images.

Authors:  A Pevsner; B Davis; S Joshi; A Hertanto; J Mechalakos; E Yorke; K Rosenzweig; S Nehmeh; Y E Erdi; J L Humm; S Larson; C C Ling; G S Mageras
Journal:  Med Phys       Date:  2006-02       Impact factor: 4.071

6.  Model-independent, multimodality deformable image registration by local matching of anatomical features and minimization of elastic energy.

Authors:  Matthias Söhn; Mattias Birkner; Yuwei Chi; Jian Wang; Yan Di; Bernhard Berger; Markus Alber
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

7.  Effect of temporal subtraction images on radiologists' detection of lung cancer on CT: results of the observer performance study with use of film computed tomography images.

Authors:  Hiroyuki Abe; Takayuki Ishida; Junji Shiraishi; Feng Li; Shigehiko Katsuragawa; Shusuke Sone; Heber Macmahon; Kunio Doi
Journal:  Acad Radiol       Date:  2004-12       Impact factor: 3.173

Review 8.  From the RSNA refresher courses: screening the cirrhotic liver for hepatocellular carcinoma with CT and MR imaging: opportunities and pitfalls.

Authors:  R L Baron; M S Peterson
Journal:  Radiographics       Date:  2001-10       Impact factor: 5.333

9.  A computer-aided temporal and dynamic subtraction technique of the liver for detection of small hepatocellular carcinomas on abdominal CT images.

Authors:  E Okumura; S Sanada; M Suzuki; O Matsui
Journal:  Phys Med Biol       Date:  2006-09-05       Impact factor: 3.609

10.  MRI signal intensity based B-spline nonrigid registration for pre- and intraoperative imaging during prostate brachytherapy.

Authors:  Sota Oguro; Junichi Tokuda; Haytham Elhawary; Steven Haker; Ron Kikinis; Clare M C Tempany; Nobuhiko Hata
Journal:  J Magn Reson Imaging       Date:  2009-11       Impact factor: 4.813

View more
  1 in total

1.  Thoracic Temporal Subtraction Three Dimensional Computed Tomography (3D-CT): Screening for Vertebral Metastases of Primary Lung Cancers.

Authors:  Shingo Iwano; Rintaro Ito; Hiroyasu Umakoshi; Takatoshi Karino; Tsutomu Inoue; Yuanzhong Li; Shinji Naganawa
Journal:  PLoS One       Date:  2017-01-17       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.