Literature DB >> 19848618

Design of a water coupling bolus with improved flow distribution for multi-element superficial hyperthermia applicators.

Kavitha Arunachalam1, Paolo F Maccarini, Jaime L Schlorff, Yngve Birkelund, Svein Jacobsen, Paul R Stauffer.   

Abstract

A water bolus used in superficial hyperthermia couples the electromagnetic (EM) or acoustic energy into the target tissue and cools the tissue surface to minimise thermal hotspots and patient discomfort during treatment. Parametric analyses of the fluid pressure inside the bolus computed using 3D fluid dynamics simulations are used in this study to determine a bolus design with improved flow and surface temperature distributions for large area superficial heat applicators. The simulation results are used in the design and fabrication of a 19 x 32 cm prototype bolus with dual input-dual output (DIDO) flow channels. Sequential thermal images of the bolus surface temperature recorded for a step change in the circulating water temperature are used to assess steady state flow and surface temperature distributions across the bolus. Modelling and measurement data indicate substantial improvement in bolus flow and surface temperature distributions when changing from the previous single input-single output (SISO) to DIDO configuration. Temperature variation across the bolus at steady state was measured to be less than 0.8 degrees C for the DIDO bolus compared to 1.5 degrees C for the SISO water bolus. The new DIDO bolus configuration maintains a nearly uniform flow distribution and low variation in surface temperature over a large area typically treated in superficial hyperthermia.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19848618      PMCID: PMC2783616          DOI: 10.3109/02656730903124506

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  28 in total

1.  SAR pattern perturbations from resonance effects in water bolus layers used with superficial microwave hyperthermia applicators.

Authors:  D G Neuman; P R Stauffer; S Jacobsen; F Rossetto
Journal:  Int J Hyperthermia       Date:  2002 May-Jun       Impact factor: 3.914

2.  Effects of waterbolus size, shape and configuration on the SAR distribution pattern of the Lucite cone applicator.

Authors:  M de Bruijne; T Samaras; J F Bakker; G C van Rhoon
Journal:  Int J Hyperthermia       Date:  2006-02       Impact factor: 3.914

3.  Construction of a conformal water bolus vest applicator for hyperthermia treatment of superficial skin cancer.

Authors:  T Juang; D Neuman; J Schlorff; P R Stauffer
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

4.  Simultaneous superficial hyperthermia and external radiotherapy: report of thermal dosimetry and tolerance to treatment.

Authors:  R J Myerson; W L Straube; E G Moros; B N Emami; H K Lee; C A Perez; M E Taylor
Journal:  Int J Hyperthermia       Date:  1999 Jul-Aug       Impact factor: 3.914

5.  FDTD simulations of Clini-Therm applicators on inhomogeneous planar tissue models.

Authors:  K W Chan; J A McDougall; C K Chou
Journal:  Int J Hyperthermia       Date:  1995 Nov-Dec       Impact factor: 3.914

6.  Progress on ThermoBrachytherapy Surface Applicator for Superficial Tissue Diseases.

Authors:  Kavitha Arunachalam; Oana I Craciunescu; Paolo F Maccarini; Jaime L Schlorff; Edward Markowitz; Paul R Stauffer
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-02-12

7.  Survival benefit of hyperthermia in a prospective randomized trial of brachytherapy boost +/- hyperthermia for glioblastoma multiforme.

Authors:  P K Sneed; P R Stauffer; M W McDermott; C J Diederich; K R Lamborn; M D Prados; S Chang; K A Weaver; L Spry; M K Malec; S A Lamb; B Voss; R L Davis; W M Wara; D A Larson; T L Phillips; P H Gutin
Journal:  Int J Radiat Oncol Biol Phys       Date:  1998-01-15       Impact factor: 7.038

8.  Multilayer conformal applicator for microwave heating and brachytherapy treatment of superficial tissue disease.

Authors:  T Juang; P R Stauffer; D G Neuman; J L Schlorff
Journal:  Int J Hyperthermia       Date:  2006-11       Impact factor: 3.914

9.  Radiation dosimetry of a conformal heat-brachytherapy applicator.

Authors:  Richard Taschereau; Paul R Stauffer; I-Chow Hsu; Jaime L Schlorff; Andrew J Milligan; Jean Pouliot
Journal:  Technol Cancer Res Treat       Date:  2004-08

Review 10.  The current and potential role of hyperthermia in radiotherapy.

Authors:  J Overgaard
Journal:  Int J Radiat Oncol Biol Phys       Date:  1989-03       Impact factor: 7.038

View more
  6 in total

1.  Thermal characteristics of thermobrachytherapy surface applicators for treating chest wall recurrence.

Authors:  K Arunachalam; P F Maccarini; O I Craciunescu; J L Schlorff; P R Stauffer
Journal:  Phys Med Biol       Date:  2010-03-12       Impact factor: 3.609

Review 2.  Conformal microwave array (CMA) applicators for hyperthermia of diffuse chest wall recurrence.

Authors:  Paul R Stauffer; Paolo Maccarini; Kavitha Arunachalam; Oana Craciunescu; Chris Diederich; Titania Juang; Francesca Rossetto; Jaime Schlorff; Andrew Milligan; Joe Hsu; Penny Sneed; Zeljko Vujaskovic
Journal:  Int J Hyperthermia       Date:  2010       Impact factor: 3.914

3.  Flow patterns and heat convection in a rectangular water bolus for use in superficial hyperthermia.

Authors:  Yngve Birkelund; Svein Jacobsen; Kavitha Arunachalam; Paolo Maccarini; Paul R Stauffer
Journal:  Phys Med Biol       Date:  2009-06-03       Impact factor: 3.609

Review 4.  Simulation techniques in hyperthermia treatment planning.

Authors:  Margarethus M Paulides; Paul R Stauffer; Esra Neufeld; Paolo F Maccarini; Adamos Kyriakou; Richard A M Canters; Chris J Diederich; Jurriaan F Bakker; Gerard C Van Rhoon
Journal:  Int J Hyperthermia       Date:  2013-05-14       Impact factor: 3.914

Review 5.  Quality assurance guidelines for superficial hyperthermia clinical trials : II. Technical requirements for heating devices.

Authors:  Hana Dobšíček Trefná; Johannes Crezee; Manfred Schmidt; Dietmar Marder; Ulf Lamprecht; Michael Ehmann; Jacek Nadobny; Josefin Hartmann; Nicolleta Lomax; Sultan Abdel-Rahman; Sergio Curto; Akke Bakker; Mark D Hurwitz; Chris J Diederich; Paul R Stauffer; Gerard C Van Rhoon
Journal:  Strahlenther Onkol       Date:  2017-03-01       Impact factor: 3.621

6.  Preclinical assessment of comfort and secure fit of thermobrachytherapy surface applicator (TBSA) on volunteer subjects.

Authors:  Kavitha Arunachalam; Oana I Craciunescu; Edward J Markewitz; Paolo F Maccarini; Jaime L Schlorff; Paul R Stauffer
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.