Literature DB >> 16423750

Effects of waterbolus size, shape and configuration on the SAR distribution pattern of the Lucite cone applicator.

M de Bruijne1, T Samaras, J F Bakker, G C van Rhoon.   

Abstract

The effects of waterbolus dimensions and configuration on the effective field size (EFS) of the Lucite cone applicator (LCA) for superficial hyperthermia are presented. The goal of the research is to develop guidelines which mark out a sub-set of optimal LCA-waterbolus set-ups. The effects of variations in (i) waterbolus thickness, (ii) waterbolus area, (iii) waterbolus length/width ratio and (iv) eccentric placement of the applicator have been investigated in an FDTD model study. The prominent effects are verified with IR thermography measurements. An optimal EFS value of 80 cm2 is found for waterbolus area of 200-400 cm2. A small (10 x 10 cm2) waterbolus area restricts the EFS to 25% of the optimal value. The sensitivity to sub-optimal waterbolus area and length/width ratio increases with waterbolus height. Eccentric placement of the LCA near the waterbolus edge reduces the EFS to up to 50% of the optimal value. The IR measurements confirm the model findings. Based on the results, the following guidelines for the clinical application of the LCA have been defined: the waterbolus (i) should extend the LCA aperture at least 2.5 cm, especially at the Lucite windows, and (ii) the height should not exceed 2 cm.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16423750     DOI: 10.1080/02656730500384297

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  4 in total

1.  Flow patterns and heat convection in a rectangular water bolus for use in superficial hyperthermia.

Authors:  Yngve Birkelund; Svein Jacobsen; Kavitha Arunachalam; Paolo Maccarini; Paul R Stauffer
Journal:  Phys Med Biol       Date:  2009-06-03       Impact factor: 3.609

Review 2.  Simulation techniques in hyperthermia treatment planning.

Authors:  Margarethus M Paulides; Paul R Stauffer; Esra Neufeld; Paolo F Maccarini; Adamos Kyriakou; Richard A M Canters; Chris J Diederich; Jurriaan F Bakker; Gerard C Van Rhoon
Journal:  Int J Hyperthermia       Date:  2013-05-14       Impact factor: 3.914

3.  Design of a water coupling bolus with improved flow distribution for multi-element superficial hyperthermia applicators.

Authors:  Kavitha Arunachalam; Paolo F Maccarini; Jaime L Schlorff; Yngve Birkelund; Svein Jacobsen; Paul R Stauffer
Journal:  Int J Hyperthermia       Date:  2009-11       Impact factor: 3.914

Review 4.  Quality assurance guidelines for superficial hyperthermia clinical trials : II. Technical requirements for heating devices.

Authors:  Hana Dobšíček Trefná; Johannes Crezee; Manfred Schmidt; Dietmar Marder; Ulf Lamprecht; Michael Ehmann; Jacek Nadobny; Josefin Hartmann; Nicolleta Lomax; Sultan Abdel-Rahman; Sergio Curto; Akke Bakker; Mark D Hurwitz; Chris J Diederich; Paul R Stauffer; Gerard C Van Rhoon
Journal:  Strahlenther Onkol       Date:  2017-03-01       Impact factor: 3.621

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.