Literature DB >> 12028636

SAR pattern perturbations from resonance effects in water bolus layers used with superficial microwave hyperthermia applicators.

D G Neuman1, P R Stauffer, S Jacobsen, F Rossetto.   

Abstract

This study examines the effect of various thickness water bolus coupling layers on the SAR (Specific Absorption Rate) patterns from Dual Concentric Conductor (DCC) based Conformal Microwave Array (CMA) superficial hyperthermia applicators. Previous theory has suggested that water bolus coupling layers can be considered as a dielectric resonator; therefore, it is possible for the impinging electric field to stimulate volume oscillations and surface wave oscillations inside the water bolus. These spurious oscillations will destructively or constructively interact with the impinging electric field to cause a perturbation of the applicator SAR pattern. An experiment was designed which consisted of mapping the electric field produced by a four element DCC CMA applicator in liquid muscle phantom at depths of 5 and 10mm in front of four different thickness water boli; 0 (no bolus) 4, 9 and 13mm. Using the Finite Difference Time Domain (FDTD) method, SAR distributions were calculated for similar test cases. It was found that for water bolus thicknesses of 9mm or greater, there is a marked perturbation of both experimental and theoretical SAR distributions. It is believed that this perturbation is experimental confirmation of the volume and surface wave oscillation theory described by previous investigators.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12028636     DOI: 10.1080/02656730110119198

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  7 in total

1.  Characterization of a digital microwave radiometry system for noninvasive thermometry using a temperature-controlled homogeneous test load.

Authors:  K Arunachalam; P R Stauffer; P F Maccarini; S Jacobsen; F Sterzer
Journal:  Phys Med Biol       Date:  2008-06-30       Impact factor: 3.609

2.  Thermal characteristics of thermobrachytherapy surface applicators for treating chest wall recurrence.

Authors:  K Arunachalam; P F Maccarini; O I Craciunescu; J L Schlorff; P R Stauffer
Journal:  Phys Med Biol       Date:  2010-03-12       Impact factor: 3.609

3.  Miniature microwave applicator for murine bladder hyperthermia studies.

Authors:  Sara Salahi; Paolo F Maccarini; Dario B Rodrigues; Wiguins Etienne; Chelsea D Landon; Brant A Inman; Mark W Dewhirst; Paul R Stauffer
Journal:  Int J Hyperthermia       Date:  2012-06-12       Impact factor: 3.914

4.  Flow patterns and heat convection in a rectangular water bolus for use in superficial hyperthermia.

Authors:  Yngve Birkelund; Svein Jacobsen; Kavitha Arunachalam; Paolo Maccarini; Paul R Stauffer
Journal:  Phys Med Biol       Date:  2009-06-03       Impact factor: 3.609

5.  Design of a water coupling bolus with improved flow distribution for multi-element superficial hyperthermia applicators.

Authors:  Kavitha Arunachalam; Paolo F Maccarini; Jaime L Schlorff; Yngve Birkelund; Svein Jacobsen; Paul R Stauffer
Journal:  Int J Hyperthermia       Date:  2009-11       Impact factor: 3.914

6.  Microwave Radiometry for Non-Invasive Detection of Vesicoureteral Reflux (VUR) Following Bladder Warming.

Authors:  Paul R Stauffer; Paolo F Maccarini; Kavitha Arunachalam; Valeria De Luca; Sara Salahi; Alina Boico; Oystein Klemetsen; Yngve Birkelund; Svein K Jacobsen; Fernando Bardati; Piero Tognolatti; Brent Snow
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011-02-22

Review 7.  Quality assurance guidelines for superficial hyperthermia clinical trials : II. Technical requirements for heating devices.

Authors:  Hana Dobšíček Trefná; Johannes Crezee; Manfred Schmidt; Dietmar Marder; Ulf Lamprecht; Michael Ehmann; Jacek Nadobny; Josefin Hartmann; Nicolleta Lomax; Sultan Abdel-Rahman; Sergio Curto; Akke Bakker; Mark D Hurwitz; Chris J Diederich; Paul R Stauffer; Gerard C Van Rhoon
Journal:  Strahlenther Onkol       Date:  2017-03-01       Impact factor: 3.621

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.