Flow patterns and heat convection in a rectangular water bolus for use in superficial hyperthermia.

Yngve Birkelund1, Svein Jacobsen, Kavitha Arunachalam, Paolo Maccarini, Paul R Stauffer.   

Abstract

This paper investigates both numerically and experimentally the spatio-temporal effects of water flow in a custom-made water bolus used for superficial hyperthermia generated by a 915-MHz, 4 x 3 microwave applicator array. Similar hyperthermia models referenced in the literature use a constant water temperature and uniform heat flux to describe conduction and convection energy exchange within the heating apparatus available to cool the tissue surface. The results presented in this paper show that the spatially varying flow pattern and rate are vital factors for the overall heat control applicability of the 5 mm thick bolus under study. Regions with low flow rates and low heat convection clearly put restrictions on the maximum microwave energy possible within the limits of skin temperature rise under the bolus. Our analysis is illustrated by experimental flow front studies using a contrast liquid set-up monitored by high definition video and complemented by numerical analysis of liquid flow and heat exchange within the rectangular water bolus loaded by malignant tissue. Important factors for the improvement of future bolus designs are also discussed in terms of diameter and configuration of the water input and output tubing network.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19494426      PMCID: PMC2735859          DOI: 10.1088/0031-9155/54/13/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  27 in total

1.  SAR pattern perturbations from resonance effects in water bolus layers used with superficial microwave hyperthermia applicators.

Authors:  D G Neuman; P R Stauffer; S Jacobsen; F Rossetto
Journal:  Int J Hyperthermia       Date:  2002 May-Jun       Impact factor: 3.914

2.  Effects of waterbolus size, shape and configuration on the SAR distribution pattern of the Lucite cone applicator.

Authors:  M de Bruijne; T Samaras; J F Bakker; G C van Rhoon
Journal:  Int J Hyperthermia       Date:  2006-02       Impact factor: 3.914

3.  Kadota Fund International Forum 2004. Application of thermal stress for the improvement of health, 15-18 June 2004, Awaji Yumebutai International Conference Center, Awaji Island, Hyogo, Japan. Final report.

Authors:  Tsutomu Sugahara; J van der Zee; Harm H Kampinga; Zeliko Vujaskovic; Motoharu Kondo; Takeo Ohnishi; Gloria Li; Heon J Park; Dennis B Leeper; Valentina Ostapenko; Elizabeth A Repasky; Masami Watanabe; Chang W Song
Journal:  Int J Hyperthermia       Date:  2008-03       Impact factor: 3.914

4.  A 433 MHz Lucite cone waveguide applicator for superficial hyperthermia.

Authors:  G C van Rhoon; P J Rietveld; J van der Zee
Journal:  Int J Hyperthermia       Date:  1998 Jan-Feb       Impact factor: 3.914

5.  Relationship between thermal dose and outcome in thermoradiotherapy treatments for superficial recurrences of breast cancer: data from a phase III trial.

Authors:  M Sherar; F F Liu; M Pintilie; W Levin; J Hunt; R Hill; J Hand; C Vernon; G van Rhoon; J van der Zee; D G Gonzalez; J van Dijk; J Whaley; D Machin
Journal:  Int J Radiat Oncol Biol Phys       Date:  1997-09-01       Impact factor: 7.038

Review 6.  Hyperthermia treatment planning.

Authors:  J J Lagendijk
Journal:  Phys Med Biol       Date:  2000-05       Impact factor: 3.609

7.  Multilayer conformal applicator for microwave heating and brachytherapy treatment of superficial tissue disease.

Authors:  T Juang; P R Stauffer; D G Neuman; J L Schlorff
Journal:  Int J Hyperthermia       Date:  2006-11       Impact factor: 3.914

8.  Assessment of the performance characteristics of a prototype 12-element capacitive contact flexible microstrip applicator (CFMA-12) for superficial hyperthermia.

Authors:  W M Lee; E A Gelvich; P van der Baan; V N Mazokhin; G C van Rhoon
Journal:  Int J Hyperthermia       Date:  2004-09       Impact factor: 3.914

9.  Randomised trial of hyperthermia as adjuvant to radiotherapy for recurrent or metastatic malignant melanoma. European Society for Hyperthermic Oncology.

Authors:  J Overgaard; D Gonzalez Gonzalez; M C Hulshof; G Arcangeli; O Dahl; O Mella; S M Bentzen
Journal:  Lancet       Date:  1995-03-04       Impact factor: 79.321

10.  Prognostic factors for tumour response and skin damage to combined radiotherapy and hyperthermia in superficial recurrent breast carcinomas.

Authors:  C E Lindholm; E Kjellén; P Nilsson; L Weber; S Hill
Journal:  Int J Hyperthermia       Date:  1995 May-Jun       Impact factor: 3.914

View more
  7 in total

1.  Thermal characteristics of thermobrachytherapy surface applicators for treating chest wall recurrence.

Authors:  K Arunachalam; P F Maccarini; O I Craciunescu; J L Schlorff; P R Stauffer
Journal:  Phys Med Biol       Date:  2010-03-12       Impact factor: 3.609

2.  Vesicoureteral reflux in children: a phantom study of microwave heating and radiometric thermometry of pediatric bladder.

Authors:  Yngve Birkelund; Øystein Klemetsen; Svein K Jacobsen; Kavitha Arunachalam; Paolo Maccarini; Paul R Stauffer
Journal:  IEEE Trans Biomed Eng       Date:  2011-09-06       Impact factor: 4.538

Review 3.  Conformal microwave array (CMA) applicators for hyperthermia of diffuse chest wall recurrence.

Authors:  Paul R Stauffer; Paolo Maccarini; Kavitha Arunachalam; Oana Craciunescu; Chris Diederich; Titania Juang; Francesca Rossetto; Jaime Schlorff; Andrew Milligan; Joe Hsu; Penny Sneed; Zeljko Vujaskovic
Journal:  Int J Hyperthermia       Date:  2010       Impact factor: 3.914

Review 4.  Simulation techniques in hyperthermia treatment planning.

Authors:  Margarethus M Paulides; Paul R Stauffer; Esra Neufeld; Paolo F Maccarini; Adamos Kyriakou; Richard A M Canters; Chris J Diederich; Jurriaan F Bakker; Gerard C Van Rhoon
Journal:  Int J Hyperthermia       Date:  2013-05-14       Impact factor: 3.914

5.  Design of a water coupling bolus with improved flow distribution for multi-element superficial hyperthermia applicators.

Authors:  Kavitha Arunachalam; Paolo F Maccarini; Jaime L Schlorff; Yngve Birkelund; Svein Jacobsen; Paul R Stauffer
Journal:  Int J Hyperthermia       Date:  2009-11       Impact factor: 3.914

Review 6.  Quality assurance guidelines for superficial hyperthermia clinical trials : II. Technical requirements for heating devices.

Authors:  Hana Dobšíček Trefná; Johannes Crezee; Manfred Schmidt; Dietmar Marder; Ulf Lamprecht; Michael Ehmann; Jacek Nadobny; Josefin Hartmann; Nicolleta Lomax; Sultan Abdel-Rahman; Sergio Curto; Akke Bakker; Mark D Hurwitz; Chris J Diederich; Paul R Stauffer; Gerard C Van Rhoon
Journal:  Strahlenther Onkol       Date:  2017-03-01       Impact factor: 3.621

7.  A Guide for Water Bolus Temperature Selection for Semi-Deep Head and Neck Hyperthermia Treatments Using the HYPERcollar3D Applicator.

Authors:  Tomas Drizdal; Gerard C van Rhoon; Rene F Verhaart; Ondrej Fiser; Margarethus M Paulides
Journal:  Cancers (Basel)       Date:  2021-12-05       Impact factor: 6.639

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.