Dose calculation accuracy using cone-beam CT (CBCT) for pelvic adaptive radiotherapy.

Huaiqun Guan1, Hang Dong.   

Abstract

This study is to evaluate the dose calculation accuracy using Varian's cone-beam CT (CBCT) for pelvic adaptive radiotherapy. We first calibrated the Hounsfield Unit (HU) to electron density (ED) for CBCT using a mini CT QC phantom embedded into an IMRT QA phantom. We then used a Catphan 500 with an annulus around it to check the calibration. The combined CT QC and IMRT phantom provided correct HU calibration, but not Catphan with an annulus. For the latter, not only was the Teflon an incorrect substitute for bone, but the inserts were also too small to provide correct HUs for air and bone. For the former, three different scan ranges (6 cm, 12 cm and 20.8 cm) were used to investigate the HU dependence on the amount of scatter. To evaluate the dose calculation accuracy, CBCT and plan-CT for a pelvic phantom were acquired and registered. The single field plan, 3D conformal and IMRT plans were created on both CT sets. Without inhomogeneity correction, the two CT generated nearly the same plan. With inhomogeneity correction, the dosimetric difference between the two CT was mainly from the HU calibration difference. The dosimetric difference for 6 MV was found to be the largest for the single lateral field plan (maximum 6.7%), less for the 3D conformal plan (maximum 3.3%) and the least for the IMRT plan (maximum 2.5%). Differences for 18 MV were generally 1-2% less. For a single lateral field, calibration with 20.8 cm achieved the minimum dosimetric difference. For 3D and IMRT plans, calibration with a 12 cm range resulted in better accuracy. Because Catphan is the standard QA phantom for the on-board imager (OBI) device, we specifically recommend not using it for the HU calibration of CBCT.

Mesh:

Substances:

Year:  2009        PMID: 19794241     DOI: 10.1088/0031-9155/54/20/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  32 in total

1.  In-treatment 4D cone-beam CT with image-based respiratory phase recognition.

Authors:  Satoshi Kida; Yoshitaka Masutani; Hideomi Yamashita; Toshikazu Imae; Taeko Matsuura; Naoya Saotome; Kuni Ohtomo; Keiichi Nakagawa; Akihiro Haga
Journal:  Radiol Phys Technol       Date:  2012-02-25

2.  Hounsfield units variations: impact on CT-density based conversion tables and their effects on dose distribution.

Authors:  B Zurl; R Tiefling; P Winkler; P Kindl; K S Kapp
Journal:  Strahlenther Onkol       Date:  2013-11-09       Impact factor: 3.621

3.  Metal artifact correction for x-ray computed tomography using kV and selective MV imaging.

Authors:  Meng Wu; Andreas Keil; Dragos Constantin; Josh Star-Lack; Lei Zhu; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

4.  Validation of a deformable image registration technique for cone beam CT-based dose verification.

Authors:  M Moteabbed; G C Sharp; Y Wang; A Trofimov; J A Efstathiou; H-M Lu
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

5.  Can CT scan protocols used for radiotherapy treatment planning be adjusted to optimize image quality and patient dose? A systematic review.

Authors:  Anne T Davis; Antony L Palmer; Andrew Nisbet
Journal:  Br J Radiol       Date:  2017-05-23       Impact factor: 3.039

6.  Dose calculation with a cone beam CT image in image-guided radiation therapy.

Authors:  Keisuke Usui; Yasunobu Ichimaru; Yasuhiro Okumura; Katsuki Murakami; Makoto Seo; Etsuo Kunieda; Koichi Ogawa
Journal:  Radiol Phys Technol       Date:  2012-09-06

7.  Relationship between x-ray illumination field size and flat field intensity and its impacts on x-ray imaging.

Authors:  Xue Dong; Tianye Niu; Xun Jia; Lei Zhu
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

8.  Practically acquired and modified cone-beam computed tomography images for accurate dose calculation in head and neck cancer.

Authors:  Chih-Chung Hu; Wen-Tao Huang; Chiao-Ling Tsai; Jian-Kuen Wu; Hsiao-Ling Chao; Guo-Ming Huang; Chun-Wei Wang; Chien-Jang Wu; Jason Chia-Hsien Cheng
Journal:  Strahlenther Onkol       Date:  2011-09-23       Impact factor: 3.621

9.  Technical Note: Density correction to improve CT number mapping in thoracic deformable image registration.

Authors:  Jinzhong Yang; Yongbin Zhang; Zijian Zhang; Lifei Zhang; Peter Balter; Laurence Court
Journal:  Med Phys       Date:  2019-04-01       Impact factor: 4.071

10.  Use of kilovoltage X-ray volume imaging in patient dose calculation for head-and-neck and partial brain radiation therapy.

Authors:  Weigang Hu; Jinsong Ye; Jiazhou Wang; Xuejun Ma; Zhen Zhang
Journal:  Radiat Oncol       Date:  2010-04-19       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.