Literature DB >> 21947125

Practically acquired and modified cone-beam computed tomography images for accurate dose calculation in head and neck cancer.

Chih-Chung Hu1, Wen-Tao Huang, Chiao-Ling Tsai, Jian-Kuen Wu, Hsiao-Ling Chao, Guo-Ming Huang, Chun-Wei Wang, Chien-Jang Wu, Jason Chia-Hsien Cheng.   

Abstract

BACKGROUND: On-line cone-beam computed tomography (CBCT) may be used to reconstruct the dose for geometric changes of patients and tumors during radiotherapy course. This study is to establish a practical method to modify the CBCT for accurate dose calculation in head and neck cancer. PATIENTS AND METHODS: Fan-beam CT (FBCT) and Elekta's CBCT were used to acquire images. The CT numbers for different materials on CBCT were mathematically modified to match them with FBCT. Three phantoms were scanned by FBCT and CBCT for image uniformity, spatial resolution, and CT numbers, and to compare the dose distribution from orthogonal beams. A Rando phantom was scanned and planned with intensity-modulated radiation therapy (IMRT). Finally, two nasopharyngeal cancer patients treated with IMRT had their CBCT image sets calculated for dose comparison.
RESULTS: With 360° acquisition of CBCT and high-resolution reconstruction, the uniformity of CT number distribution was improved and the otherwise large variations for background and high-density materials were reduced significantly. The dose difference between FBCT and CBCT was < 2% in phantoms. In the Rando phantom and the patients, the dose-volume histograms were similar. The corresponding isodose curves covering ≥ 90% of prescribed dose on FBCT and CBCT were close to each other (within 2 mm). Most dosimetric differences were from the setup errors related to the interval changes in body shape and tumor response.
CONCLUSION: The specific CBCT acquisition, reconstruction, and CT number modification can generate accurate dose calculation for the potential use in adaptive radiotherapy.

Entities:  

Mesh:

Year:  2011        PMID: 21947125     DOI: 10.1007/s00066-011-2247-1

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  28 in total

1.  Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter.

Authors:  J H Siewerdsen; D A Jaffray
Journal:  Med Phys       Date:  2001-02       Impact factor: 4.071

2.  Organ and tumor motion: an overview.

Authors:  Michael Goitein
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

3.  Re-optimization in adaptive radiotherapy.

Authors:  Chuan Wu; Robert Jeraj; Gustavo H Olivera; Thomas R Mackie
Journal:  Phys Med Biol       Date:  2002-09-07       Impact factor: 3.609

4.  Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation.

Authors:  Yong Yang; Eduard Schreibmann; Tianfang Li; Chuang Wang; Lei Xing
Journal:  Phys Med Biol       Date:  2007-01-12       Impact factor: 3.609

5.  Dose calculation on kV cone beam CT images: an investigation of the Hu-density conversion stability and dose accuracy using the site-specific calibration.

Authors:  Yi Rong; Jennifer Smilowitz; Dinesh Tewatia; Wolfgang A Tomé; Bhudatt Paliwal
Journal:  Med Dosim       Date:  2009-07-15       Impact factor: 1.482

6.  Cone beam computerized tomography: the effect of calibration of the Hounsfield unit number to electron density on dose calculation accuracy for adaptive radiation therapy.

Authors:  Joan Hatton; Boyd McCurdy; Peter B Greer
Journal:  Phys Med Biol       Date:  2009-07-10       Impact factor: 3.609

7.  Residual translational and rotational errors after kV X-ray image-guided correction of prostate location using implanted fiducials.

Authors:  Reinhold Graf; Dirk Boehmer; Volker Budach; Peter Wust
Journal:  Strahlenther Onkol       Date:  2010-09-30       Impact factor: 3.621

8.  Clinical study of the necessity of replanning before the 25th fraction during the course of intensity-modulated radiotherapy for patients with nasopharyngeal carcinoma.

Authors:  Wei Wang; Haihua Yang; Wei Hu; Guoping Shan; Weijun Ding; Changhui Yu; Biyun Wang; Xufeng Wang; Qianyi Xu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-02-06       Impact factor: 7.038

9.  The effect of significant tumor reduction on the dose distribution in intensity modulated radiation therapy for head-and-neck cancer: a case study.

Authors:  James Mechalakos; Nancy Lee; Margie Hunt; C Clifton Ling; Howard I Amols
Journal:  Med Dosim       Date:  2008-11-24       Impact factor: 1.482

10.  A study on adaptive IMRT treatment planning using kV cone-beam CT.

Authors:  George X Ding; Dennis M Duggan; Charles W Coffey; Matthew Deeley; Dennis E Hallahan; Anthony Cmelak; Arnold Malcolm
Journal:  Radiother Oncol       Date:  2007-08-20       Impact factor: 6.280

View more
  7 in total

1.  Phase-specific cone beam computed tomography reduces reconstructed volume loss of moving phantom.

Authors:  H-L Chao; W-L Chen; C-C Hu; J-K Wu; C-J Wu; J C-H Cheng
Journal:  Strahlenther Onkol       Date:  2011-12-24       Impact factor: 3.621

2.  Hounsfield units variations: impact on CT-density based conversion tables and their effects on dose distribution.

Authors:  B Zurl; R Tiefling; P Winkler; P Kindl; K S Kapp
Journal:  Strahlenther Onkol       Date:  2013-11-09       Impact factor: 3.621

3.  Validation of a deformable image registration technique for cone beam CT-based dose verification.

Authors:  M Moteabbed; G C Sharp; Y Wang; A Trofimov; J A Efstathiou; H-M Lu
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

4.  Dose-dependent deterioration of swallowing function after induction chemotherapy and definitive chemoradiotherapy for laryngopharyngeal cancer.

Authors:  M Haderlein; S Semrau; O Ott; S Speer; C Bohr; R Fietkau
Journal:  Strahlenther Onkol       Date:  2014-02       Impact factor: 3.621

5.  Target volume coverage and dose to organs at risk in prostate cancer patients. Dose calculation on daily cone-beam CT data sets.

Authors:  P Hüttenrauch; M Witt; D Wolff; S Bosold; R Engenhart-Cabillic; J Sparenberg; H Vorwerk; K Zink
Journal:  Strahlenther Onkol       Date:  2014-01-16       Impact factor: 3.621

6.  Free-breathing conformal irradiation of pancreatic cancer.

Authors:  Ignazio Solla; Sergio Zucca; Marco Possanzini; Sara Piras; Claudio Pusceddu; Sergio Porru; Gianfranco Meleddu; Paolo Farace
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

Review 7.  Adaptive radiotherapy for head and neck cancer.

Authors:  Howard E Morgan; David J Sher
Journal:  Cancers Head Neck       Date:  2020-01-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.