Literature DB >> 23039629

Relationship between x-ray illumination field size and flat field intensity and its impacts on x-ray imaging.

Xue Dong1, Tianye Niu, Xun Jia, Lei Zhu.   

Abstract

PURPOSE: X-ray cone-beam CT (CBCT) is being increasingly used for various clinical applications, while its performance is still hindered by image artifacts. This work investigates a new source of reconstruction error, which is often overlooked in the current CBCT imaging. The authors find that the x-ray flat field intensity (I(0)) varies significantly as the illumination volume size changes at different collimator settings. A wrong I(0) value leads to inaccurate CT numbers of reconstructed images as well as wrong scatter measurements in the CBCT research.
METHODS: The authors argue that the finite size of x-ray focal spot together with the detector glare effect cause the I(0) variation at different illumination sizes. Although the focal spot of commercial x-ray tubes typically has a nominal size of less than 1 mm, the off-focal-spot radiation covers an area of several millimeters on the tungsten target. Due to the large magnification factor from the field collimator to the detector, the penumbra effects of the collimator blades result in different I(0) values for different illumination field sizes. Detector glare further increases the variation, since one pencil beam of incident x-ray is scattered into an area of several centimeters on the detector. In this paper, the authors study these two effects by measuring the focal spot distribution with a pinhole assembly and the detector point spread function (PSF) with an edge-spread function method. The authors then derive a formula to estimate the I(0) value for different illumination field sizes, using the measured focal spot distribution and the detector PSF. Phantom studies are carried out to investigate the accuracy of scatter measurements and CT images with and without considering the I(0) variation effects.
RESULTS: On our tabletop system with a Varian Paxscan 4030CB flat-panel detector and a Varian RAD-94 x-ray tube as used on a clinical CBCT system, the focal spot distribution has a measured full-width-at-half-maximum (FWHM) of around 0.4 mm, while non-negligible off-focal-spot radiation is observed at a distance of over 2 mm from the center. The measured detector PSF has an FWHM of 0.510 mm, with a shape close to Gaussian. From these two distributions, the author calculate the estimated I(0) values at different collimator settings. The I(0) variation mainly comes from the focal spot effect. The estimation matches well with the measurements at different collimator widths in both horizontal and vertical directions, with an average error of less than 3%. Our method improves the accuracy of conventional scatter measurements, where the scatter is measured as the difference between fan-beam and cone-beam projections. On a uniform water cylinder phantom, more accurate I(0) suppresses the unfaithful high-frequency signals at the object boundaries of the measured scatter, and the SPR estimation error is reduced from 0.158 to 0.014. The proposed I(0) estimation also reduces the reconstruction error from about 20 HU on the Catphan©600 phantom in the selected regions of interest to less than 4 HU.
CONCLUSIONS: The I(0) variation is identified as one additional error source in x-ray imaging. By measuring the focal-spot distribution and detector PSF, the authors propose an accurate method of estimating the I(0) value for different illumination field sizes. The method obtains more accurate scatter measurements and therefore facilitates scatter correction algorithm designs. As correction methods for other CBCT artifacts become more successful, our research is significant in further improving the CBCT imaging accuracy.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23039629      PMCID: PMC3461050          DOI: 10.1118/1.4750054

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  26 in total

1.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Prototype heel effect compensation filter for cone-beam CT.

Authors:  Shinichiro Mori; Masahiro Endo; Kanae Nishizawa; Mari Ohno; Hiroaki Miyazaki; Kazuhiko Tsujita; Yasuo Saito
Journal:  Phys Med Biol       Date:  2005-11-01       Impact factor: 3.609

3.  Minimum data image reconstruction algorithms with shift-invariant filtering for helical, cone-beam CT.

Authors:  Emil Y Sidky; Yu Zou; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2005-03-30       Impact factor: 3.609

4.  Towards cardiac C-arm computed tomography.

Authors:  Günter Lauritsch; Jan Boese; Lars Wigström; Herbert Kemeth; Rebecca Fahrig
Journal:  IEEE Trans Med Imaging       Date:  2006-07       Impact factor: 10.048

5.  Scatter correction method for X-ray CT using primary modulation: theory and preliminary results.

Authors:  Lei Zhu; N Robert Bennett; Rebecca Fahrig
Journal:  IEEE Trans Med Imaging       Date:  2006-12       Impact factor: 10.048

6.  The effects of compensator and imaging geometry on the distribution of x-ray scatter in CBCT.

Authors:  G J Bootsma; F Verhaegen; D A Jaffray
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

7.  An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV.

Authors:  J M Boone; J A Seibert
Journal:  Med Phys       Date:  1997-11       Impact factor: 4.071

8.  Focal spot size measurements with pinhole and slit for microfocus mammography units.

Authors:  C Kimme-Smith; L W Bassett; R H Gold
Journal:  Med Phys       Date:  1988 May-Jun       Impact factor: 4.071

9.  Quantitative cone-beam CT imaging in radiation therapy using planning CT as a prior: first patient studies.

Authors:  Tianye Niu; Ahmad Al-Basheer; Lei Zhu
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

10.  Cone-beam-CT guided radiation therapy: A model for on-line application.

Authors:  Mark Oldham; Daniel Létourneau; Lindsay Watt; Geoffrey Hugo; Di Yan; David Lockman; Leonard H Kim; Peter Y Chen; Alvaro Martinez; John W Wong
Journal:  Radiother Oncol       Date:  2005-06       Impact factor: 6.280

View more
  8 in total

1.  Estimating scatter from sparsely measured primary signal.

Authors:  Gongting Wu; Christina R Inscoe; Jabari Calliste; Jing Shan; Yueh Z Lee; Otto Zhou; Jianping Lu
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-29

2.  Local filtration based scatter correction for cone-beam CT using primary modulation.

Authors:  Lei Zhu
Journal:  Med Phys       Date:  2016-11       Impact factor: 4.071

3.  The importance of a correct positioning of the heart using IQ-SPECT system with multifocal collimators in myocardial perfusion imaging: a phantom study.

Authors:  Federico Caobelli; Stefano Ren Kaiser; James Thomas Thackeray; Frank Michael Bengel; Matteo Chieregato; Alberto Soffientini; Claudio Pizzocaro; Giordano Savelli; Ugo Paolo Guerra; Marco Galelli; Orazio Zoccarato
Journal:  J Nucl Cardiol       Date:  2014-10-02       Impact factor: 5.952

4.  4D liver tumor localization using cone-beam projections and a biomechanical model.

Authors:  You Zhang; Michael R Folkert; Bin Li; Xiaokun Huang; Jeffrey J Meyer; Tsuicheng Chiu; Pam Lee; Joubin Nasehi Tehrani; Jing Cai; David Parsons; Xun Jia; Jing Wang
Journal:  Radiother Oncol       Date:  2018-11-14       Impact factor: 6.280

5.  The role of off-focus radiation in scatter correction for dedicated cone beam breast CT.

Authors:  Linxi Shi; Srinivasan Vedantham; Andrew Karellas; Lei Zhu
Journal:  Med Phys       Date:  2017-12-16       Impact factor: 4.071

6.  Characterization of x-ray focal spots using a rotating edge.

Authors:  Linxi Shi; N Robert Bennett; Adam S Wang
Journal:  J Med Imaging (Bellingham)       Date:  2021-03-25

7.  Modelling the penumbra in Computed Tomography1.

Authors:  Audrey Kueh; Jason M Warnett; Gregory J Gibbons; Julia Brettschneider; Thomas E Nichols; Mark A Williams; Wilfrid S Kendall
Journal:  J Xray Sci Technol       Date:  2016-05-21       Impact factor: 1.535

8.  Low-dose and scatter-free cone-beam CT imaging using a stationary beam blocker in a single scan: phantom studies.

Authors:  Xue Dong; Michael Petrongolo; Tianye Niu; Lei Zhu
Journal:  Comput Math Methods Med       Date:  2013-11-20       Impact factor: 2.238

  8 in total