Literature DB >> 19777319

Correction for respiration artefacts in myocardial perfusion SPECT is more effective when reconstructions supporting collimator detector response compensation are applied.

Gil Kovalski1, Zohar Keidar, Alex Frenkel, Ora Israel, Haim Azhari.   

Abstract

PURPOSE: To assess the impact of respiration on myocardial perfusion imaging (MPI) SPECT processed with advanced algorithmic reconstructions.
METHODS: SPECT studies obtained from a phantom simulation and 49 respiratory-gated,one-day 99mTc-sestamibi scans were corrected for respiratory-related cardiac movement. Three types of reconstruction algorithms: (a) filtered back projection (FBP), (b) ordered subset expectation maximization in which collimator detector response was incorporated (OSEMCDR), and (c) OSEM-CDR with additional attenuation and scatter corrections (OSEM-CDRACSC) were applied to the corrected and uncorrected sets and analyzed quantitatively and qualitatively.
RESULTS: A discrepancy between the corrected and uncorrected bull's eye maps > or = 10% wasfound in 2%, 10%, and 20% of the FBP, OSEM-CDR, and OSEM-CDR-ACSC scans, respectively. In studies with more than 10-mm respiratory motion, the effect of motion was greater in OSEM-CDR and OSEM-CDR-ACSC datasets as compared to FBP processing.Qualitative and quantitative differences between corrected and uncorrected sets were significantly larger in OSEM-CDR and OSEM-CDR-ACSC data than in those of FBP data.
CONCLUSIONS: Respiratory-related cardiac motion significantly affects MPI-SPECT reconstructed with advanced high-resolution reconstruction algorithms such as OSEM-CDR and OSEM-CDR-ACSC and thus may justifies the application of respiratory gating.

Entities:  

Mesh:

Year:  2009        PMID: 19777319     DOI: 10.1007/s12350-009-9148-z

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  15 in total

1.  Relative impact of scatter, collimator response, attenuation, and finite spatial resolution corrections in cardiac SPECT.

Authors:  G El Fakhri; I Buvat; H Benali; A Todd-Pokropek; R Di Paola
Journal:  J Nucl Med       Date:  2000-08       Impact factor: 10.057

Review 2.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Warren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  Circulation       Date:  2002-01-29       Impact factor: 29.690

3.  A multicenter evaluation of commercial attenuation compensation techniques in cardiac SPECT using phantom models.

Authors:  Michael K O'connor; Brad Kemp; Frank Anstett; Paul Christian; Edward P Ficaro; Eric Frey; Mark Jacobs; James N Kritzman; Robert A Pooley; Michael Wilk
Journal:  J Nucl Cardiol       Date:  2002 Jul-Aug       Impact factor: 5.952

4.  Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function.

Authors:  X Song; W P Segars; Y Du; B M W Tsui; E C Frey
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

5.  Respiratory motion of the heart: kinematics and the implications for the spatial resolution in coronary imaging.

Authors:  Y Wang; S J Riederer; R L Ehman
Journal:  Magn Reson Med       Date:  1995-05       Impact factor: 4.668

6.  Improved estimation of the detector response function for converging beam collimators.

Authors:  E C Frey; B M Tsui; G T Gullberg
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

7.  Correction of heart motion due to respiration in clinical myocardial perfusion SPECT scans using respiratory gating.

Authors:  Gil Kovalski; Ora Israel; Zohar Keidar; Alex Frenkel; Jonathan Sachs; Haim Azhari
Journal:  J Nucl Med       Date:  2007-04       Impact factor: 10.057

8.  Dual cardiac-respiratory gated PET: implementation and results from a feasibility study.

Authors:  Axel Martinez-Möller; Darko Zikic; René M Botnar; Ralph A Bundschuh; William Howe; Sibylle I Ziegler; Nassir Navab; Markus Schwaiger; Stephan G Nekolla
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02-21       Impact factor: 9.236

9.  Dual "motion-frozen heart" combining respiration and contraction compensation in clinical myocardial perfusion SPECT imaging.

Authors:  Gil Kovalski; Zohar Keidar; Alex Frenkel; Jonathan Sachs; Shai Attia; Haim Azhari
Journal:  J Nucl Cardiol       Date:  2009-01-22       Impact factor: 5.952

10.  Respiratory gating of cardiac PET data in list-mode acquisition.

Authors:  Lefteris Livieratos; Kim Rajappan; Lars Stegger; Klaus Schafers; Dale L Bailey; Paolo G Camici
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-01-17       Impact factor: 9.236

View more
  10 in total

1.  Impact of data-driven cardiac respiratory motion correction on the extent and severity of myocardial perfusion defects with free-breathing CZT SPECT.

Authors:  Doumit Daou; Rémy Sabbah; Carlos Coaguila; Hatem Boulahdour
Journal:  J Nucl Cardiol       Date:  2017-02-03       Impact factor: 5.952

2.  End-expiration respiratory gating for a high-resolution stationary cardiac SPECT system.

Authors:  Chung Chan; Mark Harris; Max Le; James Biondi; Yariv Grobshtein; Yi-Hwa Liu; Albert J Sinusas; Chi Liu
Journal:  Phys Med Biol       Date:  2014-09-26       Impact factor: 3.609

3.  Data-driven respiratory motion tracking and compensation in CZT cameras: a comprehensive analysis of phantom and human images.

Authors:  Chi-Lun Ko; Yen-Wen Wu; Mei-Fang Cheng; Ruoh-Fang Yen; Wen-Chau Wu; Kai-Yuan Tzen
Journal:  J Nucl Cardiol       Date:  2014-08-14       Impact factor: 5.952

4.  Compared vulnerabilities to small cardiac motions between different cameras used for myocardial perfusion imaging.

Authors:  Julien Salvadori; Yolande Petegnief; Remi Sabbah; Olivier Morel; Hatem Boulahdour; Gilles Karcher; Pierre-Yves Marie; Laetitia Imbert
Journal:  J Nucl Cardiol       Date:  2018-01-11       Impact factor: 5.952

5.  Correction of hysteretic respiratory motion in SPECT myocardial perfusion imaging: Simulation and patient studies.

Authors:  Paul K R Dasari; Arda Könik; P Hendrik Pretorius; Karen L Johnson; William P Segars; Mohammed S Shazeeb; Michael A King
Journal:  Med Phys       Date:  2017-02       Impact factor: 4.071

6.  Estimation and correction of cardiac respiratory motion in SPECT in the presence of limited-angle effects due to irregular respiration.

Authors:  Joyoni Dey; William P Segars; P Hendrik Pretorius; Ronn P Walvick; Philippe P Bruyant; Seth Dahlberg; Michael A King
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

7.  Real-time breath-hold triggering of myocardial perfusion imaging with a novel cadmium-zinc-telluride detector gamma camera.

Authors:  Ronny R Buechel; Aju P Pazhenkottil; Bernhard A Herzog; Lars Husmann; René N Nkoulou; Irene A Burger; Ines Valenta; Christophe A Wyss; Jelena R Ghadri; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-06-02       Impact factor: 9.236

8.  Data-driven respiratory signal estimation from temporally finely sampled projection data in conventional cardiac perfusion SPECT imaging.

Authors:  P Hendrik Pretorius; Michael A King
Journal:  Med Phys       Date:  2021-12-13       Impact factor: 4.506

9.  Gated myocardial SPECT imaging; true additional value in AMI?

Authors:  E E van der Wall; A J Scholte; J J Bax
Journal:  Int J Cardiovasc Imaging       Date:  2010-06-08       Impact factor: 2.357

10.  CT perfusion angiography; beware of artifacts!

Authors:  E E van der Wall; J D Schuijf; J J Bax; J W Jukema; M J Schalij
Journal:  Int J Cardiovasc Imaging       Date:  2009-12-24       Impact factor: 2.357

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.