Literature DB >> 20517605

Real-time breath-hold triggering of myocardial perfusion imaging with a novel cadmium-zinc-telluride detector gamma camera.

Ronny R Buechel1, Aju P Pazhenkottil, Bernhard A Herzog, Lars Husmann, René N Nkoulou, Irene A Burger, Ines Valenta, Christophe A Wyss, Jelena R Ghadri, Philipp A Kaufmann.   

Abstract

PURPOSE: The aim of this study was to assess the ability of real-time breath-hold-triggered myocardial perfusion imaging (MPI) using a novel cadmium-zinc-telluride (CZT) gamma camera to discriminate artefacts from true perfusion defects.
METHODS: A group of 40 patients underwent a 1-day (99m)Tc-tetrofosmin pharmacological stress/rest imaging protocol on a conventional dual detector SPECT gamma camera with and without attenuation correction (AC), immediately followed by scanning on an ultrafast CZT camera with and without real-time breath-hold triggering (instead of AC) by intermittent scanning confined to breath-hold at deep inspiration (using list mode acquisition). We studied the use of breath-hold triggering on the CZT camera and its ability to discriminate artefacts from true perfusion defects using AC SPECT MPI as the reference standard. Myocardial tracer uptake (percent of maximum) from CZT was compared to AC SPECT MPI by intraclass correlation and by calculating Bland-Altman limits of agreement.
RESULTS: AC of SPECT MPI identified 19 apparent perfusion defects as artefacts. Of these, 13 were correctly identified and 4 were partially unmasked (decrease in extent and/or severity) by breath-hold triggering of the CZT scan. All perfusion defects verified by SPECT MPI with AC were appropriately documented by CZT with and without breath-hold triggering. This was supported by the quantitative analysis, as the correlation (r) of myocardial tracer uptake between CZT and AC SPECT improved significantly from 0.81 to 0.90 (p<0.001) when applying breath-hold triggering. Similarly, Bland-Altman limits of agreement were narrower for CZT scans with breath-hold triggering.
CONCLUSION: This novel CZT camera allows real-time breath-hold triggering as a potential alternative to AC to assist in the discrimination of artefacts from true perfusion defects.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20517605     DOI: 10.1007/s00259-010-1480-7

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  17 in total

1.  Development of respiratory gated myocardial SPECT system.

Authors:  K Cho; S Kumiata; S Okada; T Kumazaki
Journal:  J Nucl Cardiol       Date:  1999 Jan-Feb       Impact factor: 5.952

2.  Clinical validation of SPECT attenuation correction using x-ray computed tomography-derived attenuation maps: multicenter clinical trial with angiographic correlation.

Authors:  Yasmin Masood; Yi-Hwa Liu; Gordon Depuey; Raymond Taillefer; Luis I Araujo; Steven Allen; Dominique Delbeke; Frank Anstett; Aharon Peretz; Mary-Jo Zito; Vera Tsatkin; Frans J Th Wackers
Journal:  J Nucl Cardiol       Date:  2005 Nov-Dec       Impact factor: 5.952

3.  Contributions of subdiaphragmatic activity, attenuation, and diaphragmatic motion to inferior wall artifact in attenuation-corrected Tc-99m myocardial perfusion SPECT.

Authors:  Alexander G Pitman; Victor Kalff; Bruce Van Every; Borghild Risa; Leighton R Barnden; Michael J Kelly
Journal:  J Nucl Cardiol       Date:  2005 Jul-Aug       Impact factor: 5.952

4.  Improved SPECT using simultaneous emission and transmission tomography.

Authors:  D L Bailey; B F Hutton; P J Walker
Journal:  J Nucl Med       Date:  1987-05       Impact factor: 10.057

Review 5.  Artifacts and pitfalls in myocardial perfusion imaging.

Authors:  Steven Burrell; Anita MacDonald
Journal:  J Nucl Med Technol       Date:  2006-12

6.  Correction of heart motion due to respiration in clinical myocardial perfusion SPECT scans using respiratory gating.

Authors:  Gil Kovalski; Ora Israel; Zohar Keidar; Alex Frenkel; Jonathan Sachs; Haim Azhari
Journal:  J Nucl Med       Date:  2007-04       Impact factor: 10.057

7.  Dual cardiac-respiratory gated PET: implementation and results from a feasibility study.

Authors:  Axel Martinez-Möller; Darko Zikic; René M Botnar; Ralph A Bundschuh; William Howe; Sibylle I Ziegler; Nassir Navab; Markus Schwaiger; Stephan G Nekolla
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02-21       Impact factor: 9.236

8.  Prone versus supine thallium myocardial SPECT: a method to decrease artifactual inferior wall defects.

Authors:  G M Segall; M J Davis
Journal:  J Nucl Med       Date:  1989-04       Impact factor: 10.057

9.  Technetium 99m sestamibi myocardial perfusion imaging predicts clinical outcome in the community outpatient setting. The Nuclear Utility in the Community (NUC) Study.

Authors:  Gregory S Thomas; Michael I Miyamoto; A Peter Morello; Haresh Majmundar; Jennifer J Thomas; Christine H Sampson; Rory Hachamovitch; Leslee J Shaw
Journal:  J Am Coll Cardiol       Date:  2004-01-21       Impact factor: 24.094

10.  Respiratory gating of cardiac PET data in list-mode acquisition.

Authors:  Lefteris Livieratos; Kim Rajappan; Lars Stegger; Klaus Schafers; Dale L Bailey; Paolo G Camici
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-01-17       Impact factor: 9.236

View more
  17 in total

1.  Downstream resource utilization following hybrid cardiac imaging with an integrated cadmium-zinc-telluride/64-slice CT device.

Authors:  Michael Fiechter; Jelena R Ghadri; Mathias Wolfrum; Silke M Kuest; Aju P Pazhenkottil; Rene N Nkoulou; Bernhard A Herzog; Cathérine Gebhard; Tobias A Fuchs; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-12-06       Impact factor: 9.236

2.  Advances in SPECT camera software and hardware: currently available and new on the horizon.

Authors:  E Gordon DePuey
Journal:  J Nucl Cardiol       Date:  2012-06       Impact factor: 5.952

3.  Moving ahead with CZT technology.

Authors:  Dominik C Benz; Ronny R Buechel
Journal:  J Nucl Cardiol       Date:  2015-11-10       Impact factor: 5.952

4.  Attenuation correction in stress-only myocardial perfusion imaging.

Authors:  Aju P Pazhenkottil; Philipp A Kaufmann; Oliver Gaemperli
Journal:  J Nucl Cardiol       Date:  2016-01-29       Impact factor: 5.952

5.  Novel 99mTc(III)-azide complexes [99mTc(N3)(CDO)(CDOH)2B-R] (CDOH2=cyclohexanedione dioxime) as potential radiotracers for heart imaging.

Authors:  Min Liu; Yumin Zheng; Ugur Avcibasi; Shuang Liu
Journal:  Nucl Med Biol       Date:  2016-05-09       Impact factor: 2.408

Review 6.  The future of SPECT MPI: time and dose reduction.

Authors:  Milena J Henzlova; W Lane Duvall
Journal:  J Nucl Cardiol       Date:  2011-08       Impact factor: 5.952

7.  Impact of data-driven cardiac respiratory motion correction on the extent and severity of myocardial perfusion defects with free-breathing CZT SPECT.

Authors:  Doumit Daou; Rémy Sabbah; Carlos Coaguila; Hatem Boulahdour
Journal:  J Nucl Cardiol       Date:  2017-02-03       Impact factor: 5.952

8.  End-expiration respiratory gating for a high-resolution stationary cardiac SPECT system.

Authors:  Chung Chan; Mark Harris; Max Le; James Biondi; Yariv Grobshtein; Yi-Hwa Liu; Albert J Sinusas; Chi Liu
Journal:  Phys Med Biol       Date:  2014-09-26       Impact factor: 3.609

9.  Data-driven respiratory motion tracking and compensation in CZT cameras: a comprehensive analysis of phantom and human images.

Authors:  Chi-Lun Ko; Yen-Wen Wu; Mei-Fang Cheng; Ruoh-Fang Yen; Wen-Chau Wu; Kai-Yuan Tzen
Journal:  J Nucl Cardiol       Date:  2014-08-14       Impact factor: 5.952

10.  Newer generation cameras are preferred.

Authors:  Ronny R Buechel; Oliver Gaemperli
Journal:  J Nucl Cardiol       Date:  2016-04-12       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.