Literature DB >> 19763636

Safety of thoracic pedicle screw application using the funnel technique in Asians: a cadaveric evaluation.

Chris Yin Wei Chan1, Mun Keong Kwan, Lim Beng Saw.   

Abstract

The objective of this cadaveric study is to determine the safety and outcome of thoracic pedicle screw placement in Asians using the funnel technique. Pedicle screws have superior biomechanical as well as clinical data when compared to other methods of instrumentation. However, misplacement in the thoracic spine can result in major neurological implications. There is great variability of the thoracic pedicle morphometry between the Western and the Asian population. The feasibility of thoracic pedicle screw insertion in Asians has not been fully elucidated yet. A pre-insertion radiograph was performed and surgeons were blinded to the morphometry of the thoracic pedicles. 240 pedicle screws were inserted in ten Asian cadavers from T1 to T12 using the funnel technique. 5.0 mm screws were used from T1 to T6 while 6.0 mm screws were used from T7 to T12. Perforations were detected by direct visualization via a wide laminectomy. The narrowest pedicles are found between T3 and T6. T5 pedicle width is smallest measuring 4.1 +/- 1.3 mm. There were 24 (10.0%) Grade 1 perforations and only 1 (0.4%) Grade 2 perforation. Grade 2 or worse perforation is considered significant perforation which would threaten the neural structures. There were twice as many lateral and inferior perforations compared to medial perforations. 48.0% of the perforations occurred at T1, T2 and T3 pedicles. Pedicle fracture occurred in 10.4% of pedicles. Intra-operatively, the absence of funnel was found in 24.5% of pedicles. In conclusion, thoracic pedicle screws using 5.0 mm at T1-T6 and 6.0 mm at T7-T12 can be inserted safely in Asian cadavers using the funnel technique despite having smaller thoracic pedicle morphometry.

Entities:  

Mesh:

Year:  2009        PMID: 19763636      PMCID: PMC2899730          DOI: 10.1007/s00586-009-1157-8

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  23 in total

1.  The accuracy of pedicle screw placement in the thoracic spine using the "Funnel Technique": part 1. A cadaveric study.

Authors:  Wicharn Yingsakmonkol; Eldin Karaikovic; Robert W Gaines
Journal:  J Spinal Disord Tech       Date:  2002-12

2.  Thoracic pedicle screw instrumentation using the "Funnel Technique": part 2. Clinical experience.

Authors:  Michael Viau; B Bus Tarbox; Sakarin Wonglertsiri; Eldin E Karaikovic; Wicharn Yingsakmongkol; Robert W Gaines
Journal:  J Spinal Disord Tech       Date:  2002-12

3.  Quantitative three-dimensional anatomy of cervical, thoracic and lumbar vertebrae of Chinese Singaporeans.

Authors:  S H Tan; E C Teo; H C Chua
Journal:  Eur Spine J       Date:  2003-12-12       Impact factor: 3.134

4.  Morphometric study of the thoracic vertebral pedicle in an Indian population.

Authors:  Sandeep P Datir; Sajal R Mitra
Journal:  Spine (Phila Pa 1976)       Date:  2004-06-01       Impact factor: 3.468

5.  Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement.

Authors:  Ganesh Rao; Darrel S Brodke; Matthew Rondina; Andrew T Dailey
Journal:  J Neurosurg       Date:  2002-09       Impact factor: 5.115

6.  Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries.

Authors:  S Rajasekaran; S Vidyadhara; Perumal Ramesh; Ajoy P Shetty
Journal:  Spine (Phila Pa 1976)       Date:  2007-01-15       Impact factor: 3.468

7.  The treatment of unstable thoracic spine fractures with transpedicular screw instrumentation: a 3-year consecutive series.

Authors:  James J Yue; Allen Sossan; Christopher Selgrath; Lawrence S Deutsch; Kenneth Wilkens; Mark Testaiuti; Josue P Gabriel
Journal:  Spine (Phila Pa 1976)       Date:  2002-12-15       Impact factor: 3.468

Review 8.  Successful short-segment instrumentation and fusion for thoracolumbar spine fractures: a consecutive 41/2-year series.

Authors:  J W Parker; J R Lane; E E Karaikovic; R W Gaines
Journal:  Spine (Phila Pa 1976)       Date:  2000-05-01       Impact factor: 3.468

Review 9.  Comparative analysis of pedicle screw versus hook instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis.

Authors:  Yongjung J Kim; Lawrence G Lenke; Samuel K Cho; Keith H Bridwell; Brenda Sides; Kathy Blanke
Journal:  Spine (Phila Pa 1976)       Date:  2004-09-15       Impact factor: 3.468

10.  Biomechanical evaluation of contemporary posterior spinal internal fixation configurations in an unstable burst-fracture calf spine model: special references of hook configurations and pedicle screws.

Authors:  Howard S An; Kern Singh; Alexander R Vaccaro; G Wang; H Yoshida; Jason Eck; L McGrady; Tae-Hong Lim
Journal:  Spine (Phila Pa 1976)       Date:  2004-02-01       Impact factor: 3.468

View more
  7 in total

1.  A comparison of feasibility and safety of percutaneous fluoroscopic guided thoracic pedicle screws between Europeans and Asians: is there any difference?

Authors:  Mun Keong Kwan; Chee Kidd Chiu; Chris Yin Wei Chan; Reza Zamani; Nils Hansen-Algenstaedt
Journal:  Eur Spine J       Date:  2015-07-30       Impact factor: 3.134

Review 2.  Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review.

Authors:  Ahmed A Aoude; Maryse Fortin; Rainer Figueiredo; Peter Jarzem; Jean Ouellet; Michael H Weber
Journal:  Eur Spine J       Date:  2015-03-07       Impact factor: 3.134

3.  The "slide technique": an improvement on the "funnel technique" for safe pedicle screw placement in the thoracic spine.

Authors:  Raphaël Vialle; Reinhard Zeller; Robert W Gaines
Journal:  Eur Spine J       Date:  2014-05-14       Impact factor: 3.134

4.  Three-dimensional digitizing and anatomic study of lumbar vertebral canal and pedicle in children.

Authors:  Xing Wang; Shao-Jie Zhang; Yuan-Zhi Zhang; Xiao-He Li; Zhi-Feng Zhang; Chao-Qun Wang; Shang Gao; Jun Shi; Zhi-Jun Li
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2018-08-08       Impact factor: 1.195

5.  Percutaneous pedicle screw for unstable spine fractures in polytraumatized patients: A report of two cases.

Authors:  Boon Beng Tan; Chris Yin Wei Chan; Lim Beng Saw; Mun Keong Kwan
Journal:  Indian J Orthop       Date:  2012-11       Impact factor: 1.251

6.  Anatomical and radiologic characteristics of isthmus parameters in guiding pedicle screw placement.

Authors:  Paerhati Rexiti; Yakufu Abulizi; Aikeremujiang Muheremu; Shuiquan Wang; Maierdan Maimaiti; Hailong Guo; Weibin Sheng
Journal:  J Int Med Res       Date:  2018-04-05       Impact factor: 1.671

Review 7.  Biomechanics and clinical outcome after posterior stabilization of mid-thoracic vertebral body fractures: a systematic literature review.

Authors:  Ulrich J Spiegl; Georg Osterhoff; Philipp Bula; Frank Hartmann; Max J Scheyerer; Klaus J Schnake; Bernhard W Ullrich
Journal:  Eur J Trauma Emerg Surg       Date:  2020-12-02       Impact factor: 3.693

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.