Thoracic pedicle screw instrumentation using the "Funnel Technique": part 2. Clinical experience.

Michael Viau1, B Bus Tarbox, Sakarin Wonglertsiri, Eldin E Karaikovic, Wicharn Yingsakmongkol, Robert W Gaines.   

Abstract

This study is a retrospective review of the clinical results of patients treated with thoracic pedicle screws using the "funnel technique." The objective is to report the clinical results of patients treated with thoracic pedicle screws using the funnel technique for screw placement. A total of 115 patients treated with the use of at least one thoracic pedicle screw were retrospectively identified. All patients were treated at a single medical center, under the senior author's supervision. Twenty-five different residents were responsible for placing 50-60% of these screws, and five different fellows and the senior author placed the remainder. The accuracy of screw placement and the complications related to the use of thoracic pedicle screws were analyzed by assessing intraoperative and postoperative charts and radiographs. There were 115 patients (age range 9-82 years) with the average follow-up period of 17 months. The total number of screws used was 348; the screw diameter ranged from 4.0 to 7.75 mm. There were no vascular or pulmonary complications. There was no iatrogenic neurologic injury, except for one patient who developed a transient anterior thigh numbness from intraoperative positioning. In fracture patients, 35% (10 of 28) had documented neurologic improvement postoperatively. There were no obviously misplaced pedicle screws on detailed review of intraoperative and postoperative radiographs. No screws had to be electively removed for complications related to misplacement. There were four broken screws, one broken rod, two loose screws, and three connector disengagements. Two patients had deep infections and four patients had pseudarthrosis requiring additional surgery. The clinical results proved that thoracic pedicle screws can be safely placed with the funnel technique.

Entities:  

Mesh:

Year:  2002        PMID: 12468968     DOI: 10.1097/00024720-200212000-00002

Source DB:  PubMed          Journal:  J Spinal Disord Tech        ISSN: 1536-0652


  13 in total

Review 1.  Treatment options for thoracolumbar spine fractures.

Authors:  Eldin E Karaiković; Hector O Pacheco
Journal:  Bosn J Basic Med Sci       Date:  2005-05       Impact factor: 3.363

2.  Safety of thoracic pedicle screw application using the funnel technique in Asians: a cadaveric evaluation.

Authors:  Chris Yin Wei Chan; Mun Keong Kwan; Lim Beng Saw
Journal:  Eur Spine J       Date:  2009-09-11       Impact factor: 3.134

3.  Use of computed tomographic reconstruction to establish the ideal entry point for pedicle screws in idiopathic scoliosis.

Authors:  Peiqiang Su; Wentong Zhang; Yan Peng; Anjing Liang; Kaili Du; Dongsheng Huang
Journal:  Eur Spine J       Date:  2011-08-13       Impact factor: 3.134

Review 4.  Pedicle screw insertion techniques: an update and review of the literature.

Authors:  F Perna; R Borghi; F Pilla; N Stefanini; A Mazzotti; M Chehrassan
Journal:  Musculoskelet Surg       Date:  2016-11-19

5.  The effect of starting point placement technique on thoracic transverse process strength: an ex vivo biomechanical study.

Authors:  Barrett S Brown; Terence E McIff; Rudolph C Glattes; Douglas C Burton; Marc A Asher
Journal:  Scoliosis       Date:  2010-07-13

6.  Morphologic evaluation of the thoracic vertebrae for safe free-hand pedicle screw placement in adolescent idiopathic scoliosis: a CT-based anatomical study.

Authors:  Guanyu Cui; Kota Watanabe; Naobumi Hosogane; Takashi Tsuji; Ken Ishii; Masaya Nakamura; Yoshiaki Toyama; Kazuhiro Chiba; Lawrence G Lenke; Morio Matsumoto
Journal:  Surg Radiol Anat       Date:  2011-07-08       Impact factor: 1.246

7.  The "slide technique": an improvement on the "funnel technique" for safe pedicle screw placement in the thoracic spine.

Authors:  Raphaël Vialle; Reinhard Zeller; Robert W Gaines
Journal:  Eur Spine J       Date:  2014-05-14       Impact factor: 3.134

8.  Accuracy and safety of free-hand pedicle screw fixation in age less than 10 years.

Authors:  Hyoung Yeon Seo; Ji Hyeon Yim; Jung Pil Heo; Abhishek S Patil; Seung Min Na; Sung Kyu Kim; Jae Yoon Chung
Journal:  Indian J Orthop       Date:  2013-11       Impact factor: 1.251

9.  Accuracy of free hand pedicle screw installation in the thoracic and lumbar spine by a young surgeon: an analysis of the first consecutive 306 screws using computed tomography.

Authors:  Chang-Hyun Lee; Seung-Jae Hyun; Yongjung J Kim; Ki-Jeong Kim; Tae-Ahn Jahng; Hyun-Jib Kim
Journal:  Asian Spine J       Date:  2014-06-09

10.  The Indian Basket Trick: a case of delayed paraplegia with complete recovery, caused by misplaced thoracic pedicle screw.

Authors:  Antonin Leroy; Reda Kabbaj; Arnaud Dubory; Manon Bachy; Anne-Isabelle Vermersch; Raphaël Vialle
Journal:  Springerplus       Date:  2016-06-30
View more