Modification of the NEMA XR21-2000 cardiac phantom for testing of imaging systems used in endovascular image guided interventions.

C N Ionita1, A Dohatcu, A Jain, C Keleshis, K R Hoffmann, D R Bednarek, S Rudin.   

Abstract

X-ray equipment testing using phantoms that mimic the specific human anatomy, morphology, and structure is a very important step in the research, development, and routine quality assurance for such equipment. Although the NEMA XR21 phantom exists for cardiac applications, there is no such standard phantom for neuro-, peripheral and cardio-vascular angiographic applications. We have extended the application of the NEMA XR21-2000 phantom to evaluate neurovascular x-ray imaging systems by structuring it to be head-equivalent; two aluminum plates shaped to fit into the NEMA phantom geometry were added to a 15 cm thick section. Also, to enable digital subtraction angiography (DSA) testing, two replaceable central plates with a hollow slot were made so that various angiographic sections could be inserted into the phantom. We tested the new modified phantom using a flat panel C-arm unit dedicated for endovascular image-guided interventions. All NEMA XR21-2000 standard test sections were used in evaluations with the new "head-equivalent" phantom. DSA and DA are able to be tested using two standard removable blocks having simulated arteries of various thickness and iodine concentrations (AAPM Report 15). The new phantom modifications have the benefits of enabling use of the standard NEMA phantom for angiography in both neuro- and cardio-vascular applications, with the convenience of needing only one versatile phantom for multiple applications. Additional benefits compared to using multiple phantoms are increased portability and lower cost.

Entities:  

Year:  2009        PMID: 19756259      PMCID: PMC2743264          DOI: 10.1117/12.813533

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  2 in total

1.  A new tool for benchmarking cardiovascular fluoroscopes.

Authors:  S Balter; F A Heupler; P J Lin; M H Wondrow
Journal:  Catheter Cardiovasc Interv       Date:  2001-01       Impact factor: 2.692

2.  Implementation of a high-sensitivity Micro-Angiographic Fluoroscope (HS-MAF) for in-vivo endovascular image guided interventions (EIGI) and region-of-interest computed tomography (ROI-CT).

Authors:  C N Ionita; C Keleshis; V Patel; G Yadava; K R Hoffmann; D R Bednarek; A Jain; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008
  2 in total
  9 in total

1.  Investigation of metrics to assess vascular flow modifications for diverter device designs using hydrodynamics and angiographic studies.

Authors:  Ciprian N Ionita; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-23

2.  New head equivalent phantom for task and image performance evaluation representative for neurovascular procedures occurring in the Circle of Willis.

Authors:  Ciprian N Ionita; Brendan Loughran; Amit Jain; S N Swetadri Vasan; Daniel R Bednarek; Elad Levy; Adnan H Siddiqui; Kenneth V Snyder; L N Hopkins; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-02-23

3.  Investigation of the need for an x-ray scatter-reduction grid during neurointerventional procedures.

Authors:  S V Setlur Nagesh; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15

4.  Anti-scatter grid artifact elimination for high resolution x-ray imaging CMOS detectors.

Authors:  R Rana; V Singh; A Jain; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-18

5.  Use of the microangiographic fluoroscope for coiling of intracranial aneurysms.

Authors:  Mandy J Binning; David Orion; Parham Yashar; Sharon Webb; Ciprian N Ionita; Amit Jain; Stephen Rudin; L Nelson Hopkins; Adnan H Siddiqui; Elad I Levy
Journal:  Neurosurgery       Date:  2011-11       Impact factor: 4.654

6.  Evaluation of intracranial aneurysm coil embolization in phantoms and patients using a high-resolution Microangiographic Fluoroscope (MAF).

Authors:  Ciprian N Ionita; Amit Jain; Brendan Loughran; Swetadri Vasan S N; Daniel R Bednarek; Elad Levy; Adnan H Siddiqui; Kenneth V Snyder; L N Hopkins; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-02

7.  Limitations of anti-scatter grids when used with high resolution image detectors.

Authors:  V Singh; A Jain; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-19

8.  Evaluation of image lag in a flat-panel, detector-equipped cardiovascular X-ray machine using a newly developed dynamic phantom.

Authors:  Hisaya Sato; Keisuke Kondo; Kyoichi Kato; Yasuo Nakazawa
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

9.  Development of a dynamic blood vessel phantom for evaluation of moving images.

Authors:  Miwa Osawa; Keisuke Kondo; Sato Hisaya; Kyoichi Kato
Journal:  J Appl Clin Med Phys       Date:  2019-11-28       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.