A new tool for benchmarking cardiovascular fluoroscopes.

S Balter1, F A Heupler, P J Lin, M H Wondrow.   

Abstract

This article reports the status of a new cardiovascular fluoroscopy benchmarking phantom. A joint working group of the Society for Cardiac Angiography and Interventions (SCA&I) and the National Electrical Manufacturers Association (NEMA) developed the phantom. The device was adopted as NEMA standard XR 21-2000, "Characteristics of and Test Procedures for a Phantom to Benchmark Cardiac Fluoroscopic and Photographic Performance," in August 2000. The test ensemble includes imaging field geometry, spatial resolution, low-contrast iodine detectability, working thickness range, visibility of moving targets, and phantom entrance dose. The phantom tests systems under conditions simulating normal clinical use for fluoroscopically guided invasive and interventional procedures. Test procedures rely on trained human observers.

Entities:  

Mesh:

Year:  2001        PMID: 11146526     DOI: 10.1002/1522-726x(200101)52:1<67::aid-ccd1016>3.0.co;2-l

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  4 in total

1.  New head equivalent phantom for task and image performance evaluation representative for neurovascular procedures occurring in the Circle of Willis.

Authors:  Ciprian N Ionita; Brendan Loughran; Amit Jain; S N Swetadri Vasan; Daniel R Bednarek; Elad Levy; Adnan H Siddiqui; Kenneth V Snyder; L N Hopkins; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-02-23

Review 2.  Management of pediatric radiation dose using GE fluoroscopic equipment.

Authors:  Barry Belanger; John Boudry
Journal:  Pediatr Radiol       Date:  2006-09

3.  Modification of the NEMA XR21-2000 cardiac phantom for testing of imaging systems used in endovascular image guided interventions.

Authors:  C N Ionita; A Dohatcu; A Jain; C Keleshis; K R Hoffmann; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009

4.  Variability in radiation dose and image quality: A comparison across fluoroscopy-system vendors, generations of equipment and institutions.

Authors:  Kevin D Hill; Steve D Mann; Michael P Carboni; Thomas P Doyle; Salim F Idriss; Dana F Janssen; George T Nicholson; Shyam Sathanandam; Greg A Fleming
Journal:  Catheter Cardiovasc Interv       Date:  2018-09-12       Impact factor: 2.692

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.