Literature DB >> 19698909

Two-year radiostereometric analysis evaluation of femoral head penetration in a challenging population of young total hip arthroplasty patients.

David C Ayers1, Peyton L Hays, Jacob M Drew, Mark S Eskander, Daniel Osuch, Charles R Bragdon.   

Abstract

This prospective, randomized protocol evaluated femoral head penetration after total hip arthroplasty in a young population. Forty-five patients randomly received either a cross-linked or conventional ultrahigh-molecular-weight polyethylene (UHMWPE) liner in a noncemented hemispheric cup (Trilogy, Zimmer, Warsaw, Ind) with a 28-mm femoral head. Radiostereometric analysis film pairs, Harris hip, UCLA, SF-12, and Western Ontario and McMaster Universities scores were obtained through 2 years. Median femoral head penetration was less among cross-linked compared to conventional liners as follows: 0.06 mm (0.04-0.08 mm) vs 0.08 mm (0.02-0.19 mm) at 6 months, 0.07 mm (-0.14 to 0.16 mm) vs 0.11 mm (0.01-0.27 mm) at 1 year, and 0.065 mm (-0.04 to 0.193 mm) vs 0.169 mm (0.09-0.22 mm) at 2 years. Clinical outcomes were similar between the groups. Highly cross-linked UHMWPE demonstrated 55% less femoral head penetration compared to conventional polyethylene at 2 years. Despite improvements in the manufacturing process and sterilization of conventional UHMWPE, the femoral head penetration rate is unchanged from historical standards.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19698909     DOI: 10.1016/j.arth.2009.05.027

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  The incidence of acetabular osteolysis in young patients with conventional versus highly crosslinked polyethylene.

Authors:  Nathan A Mall; Ryan M Nunley; Jin Jun Zhu; William J Maloney; Robert L Barrack; John C Clohisy
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

2.  Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.

Authors:  David C Ayers; Meridith Greene; Benjamin Snyder; Michelle Aubin; Jacob Drew; Charles Bragdon
Journal:  J Bone Joint Surg Am       Date:  2015-04-15       Impact factor: 5.284

Review 3.  History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene.

Authors:  Steven M Kurtz; Heather A Gawel; Jasmine D Patel
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

4.  The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA.

Authors:  Charles R Bragdon; Michael Doerner; John Martell; Bryan Jarrett; Henrik Palm; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

Review 5.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

Review 6.  Wear of highly crosslinked polyethylene acetabular components.

Authors:  Stuart A Callary; Lucian B Solomon; Oksana T Holubowycz; David G Campbell; Zachary Munn; Donald W Howie
Journal:  Acta Orthop       Date:  2014-10-10       Impact factor: 3.717

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.