Literature DB >> 19679281

Impact of a reduced tube voltage on CT angiography and radiation dose: results of the PROTECTION I study.

Bernhard Bischoff1, Franziska Hein, Tanja Meyer, Martin Hadamitzky, Stefan Martinoff, Albert Schömig, Jörg Hausleiter.   

Abstract

OBJECTIVES: The aim of this study was to determine the impact of a reduced 100-kV tube voltage on image quality and radiation exposure in a pre-defined subgroup analysis of the international, multicenter radiation dose survey PROTECTION I (Prospective Multicenter Study on RadiaTion Dose Estimates Of Cardiac CT AngIOgraphy I) study.
BACKGROUND: Cardiac computed tomography angiography (CCTA) has become a frequently used diagnostic tool in clinical practice. Despite continually improving CT technology, there remain concerns regarding the associated radiation exposure. A reduced tube voltage of 100 kV has been proposed as an effective means for dose reduction in nonobese patients.
METHODS: The study assessed the relevant radiation dose parameters as well as quantitative and qualitative diagnostic image quality data in a subgroup of 321 patients (100 kV: 82 patients; 120 kV: 239 patients), who were scanned at study sites that applied a 100-kV tube voltage in at least 1 patient. Diagnostic image quality was assessed by an experienced CCTA investigator with a 4-point score (1: nondiagnostic to 4: excellent image quality). Effective radiation dose was estimated from the dose-length-product of each CCTA study.
RESULTS: The use of the 100-kV scan protocol was associated with 53% reduction in CCTA median radiation dose estimates, when compared with the conventional 120-kV scan protocol (p < 0.001). Although image noise significantly increased by 26.3% with 100 kV, signal- as well as contrast-to-noise ratios also increased by 7.9% (p = 0.254) and 10.8% (p = 0.027), respectively. Reduction of tube voltage did not impair diagnostic image quality (median diagnostic score: 3.5 [3.25 to 3.75] vs. 3.5 [3.0 to 3.75] for 100 kV vs. 120 kV; p = 0.22).
CONCLUSIONS: In this nonrandomized PROTECTION I dose survey, reducing the CCTA tube voltage to 100 kV in nonobese patients is associated with a significant reduction in radiation exposure while maintaining diagnostic image quality. Thus, the 100-kV scan technique should be considered for CCTA dose reduction in adequately selected patients.

Entities:  

Mesh:

Year:  2009        PMID: 19679281     DOI: 10.1016/j.jcmg.2009.02.015

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  61 in total

Review 1.  Low-dose cardiovascular computed tomography: where are the limits?

Authors:  Paul Schoenhagen; Carla M Thompson; Sandra S Halliburton
Journal:  Curr Cardiol Rep       Date:  2012-02       Impact factor: 2.931

Review 2.  [Strategies for reducing the CT radiation dose].

Authors:  S T Schindera; C Nauer; R Treier; P Trueb; G von Allmen; P Vock; Z Szucs-Farkas
Journal:  Radiologe       Date:  2010-12       Impact factor: 0.635

3.  Low dose dual-source CT angiography of the thoracic aorta.

Authors:  Cormac Farrelly; Amir Davarpanah; Aoife N Keeling; John Sheehan; Ann Ragin; Vahid Yaghmai; James C Carr
Journal:  Int J Cardiovasc Imaging       Date:  2010-11-03       Impact factor: 2.357

Review 4.  Low dose CT of the heart: a quantum leap into a new era of cardiovascular imaging.

Authors:  E Maffei; C Martini; S De Crescenzo; T Arcadi; A Clemente; E Capuano; A Rossi; R Malagò; N Mollet; A Weustink; C Tedeschi; L La Grutta; S Seitun; A Igoren Guaricci; F Cademartiri
Journal:  Radiol Med       Date:  2010-06-23       Impact factor: 3.469

5.  Reduced iodine load with CT coronary angiography using dual-energy imaging: a prospective randomized trial compared with standard coronary CT angiography.

Authors:  Rekha Raju; Angus G Thompson; Kristy Lee; Bruce Precious; Tae-Hyun Yang; Adam Berger; Carolyn Taylor; Brett Heilbron; Giang Nguyen; James Earls; James Min; Patricia Carrascosa; Darra Murphy; Cameron Hague; Jonathon A Leipsic
Journal:  J Cardiovasc Comput Tomogr       Date:  2014-06-17

6.  Quantitative analysis of left ventricular dyssynchrony using cardiac computed tomography versus three-dimensional echocardiography.

Authors:  Sebastian J Buss; Felix Schulz; David Wolf; Waldemar Hosch; Christian Galuschky; Georg Schummers; Evangelos Giannitsis; Hans-Ulrich Kauczor; Christian Zugck; Ruediger Becker; Stefan E Hardt; Hugo A Katus; Grigorios Korosoglou
Journal:  Eur Radiol       Date:  2012-01-22       Impact factor: 5.315

7.  Radiation dose of coronary CT angiography with a third-generation dual-source CT in a "real-world" patient population.

Authors:  Aleksander Kosmala; Bernhard Petritsch; Andreas Max Weng; Thorsten Alexander Bley; Tobias Gassenmaier
Journal:  Eur Radiol       Date:  2018-11-30       Impact factor: 5.315

8.  Importance of consideration of radiation doses from cardiac imaging procedures and risks of cancer.

Authors:  George A Beller
Journal:  J Nucl Cardiol       Date:  2010 Jan-Feb       Impact factor: 5.952

Review 9.  Established and emerging dose reduction methods in cardiac computed tomography.

Authors:  Gary R Small; Mustapha Kazmi; Robert A Dekemp; Benjamin J W Chow
Journal:  J Nucl Cardiol       Date:  2011-08       Impact factor: 5.952

10.  Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study.

Authors:  Felix G Meinel; Christian Canstein; U Joseph Schoepf; Martin Sedlmaier; Bernhard Schmidt; Brett S Harris; Thomas G Flohr; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2014-05-10       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.