Literature DB >> 19651410

Kinematic evaluation of cruciate-retaining total knee replacement patients during level walking: a comparison with the displacement-controlled ISO standard.

Valentina Ngai1, Markus A Wimmer.   

Abstract

Differences between wear-scar features of simulator-tested and retrieved tibial total knee replacement (TKR) liners have been reported. This disagreement may result from differences between in vivo kinematic profiles and those defined by the International Organization for Standardization (ISO). The purpose of this study was to determine the knee kinematics of a TKR subject group during level walking and compare them with the motion profiles defined by the ISO standard for a displacement-controlled knee wear testing simulator. Twenty-nine patients with a posterior cruciate ligament-retaining TKR design were gait tested using the point cluster technique to obtain flexion-extension (FE) rotation, anterior-posterior (AP) translation and internal-external (IE) rotation knee motions during a complete cycle of level walking. Relative ranges of motion and timing of key points within the in vivo motion data were compared against the same ranges and same key points from the input profiles of the displacement-controlled wear testing standard ISO14243-3. The subjects exhibited a FE pattern similar to ISO, with an insignificant difference in range of FE rotation from midstance to terminal stance. However, the subjects had a significantly higher range of knee flexion from terminal stance into swing. The subjects also exhibited a phase delay for the entire gait cycle. For AP translation, the standard profile had statistically significant lower magnitudes than seen in vivo. Opposite pattern of AP motion was also apparent from midstance and swing. Similarly, ISO specified a smaller IE total range of rotation with a motion pattern in complete opposition to that seen in vivo. In conclusion, significant differences were found in both the magnitudes and pattern of in vivo motion compared with ISO.

Entities:  

Mesh:

Year:  2009        PMID: 19651410      PMCID: PMC2757531          DOI: 10.1016/j.jbiomech.2009.06.030

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  28 in total

1.  Design forms of total knee replacement.

Authors:  P S Walker; S Sathasivam
Journal:  Proc Inst Mech Eng H       Date:  2000       Impact factor: 1.617

2.  Correcting for deformation in skin-based marker systems.

Authors:  E J Alexander; T P Andriacchi
Journal:  J Biomech       Date:  2001-03       Impact factor: 2.712

3.  Normalized speed, not age, characterizes ground reaction force patterns in 5-to 12-year-old children walking at self-selected speeds.

Authors:  B W Stansfield; S J Hillman; M E Hazlewood; A A Lawson; A M Mann; I R Loudon; J E Robb
Journal:  J Pediatr Orthop       Date:  2001 May-Jun       Impact factor: 2.324

4.  In vivo fluoroscopic analysis of fixed-bearing total knee replacements.

Authors:  Douglas A Dennis; Richard D Komistek; Mohamed R Mahfouz
Journal:  Clin Orthop Relat Res       Date:  2003-05       Impact factor: 4.176

5.  Effect of stair descent loading on ultra-high molecular weight polyethylene wear in a force-controlled knee simulator.

Authors:  L C Benson; J D DesJardins; M K Harman; M LaBerge
Journal:  Proc Inst Mech Eng H       Date:  2002       Impact factor: 1.617

6.  Polyethylene damage and knee kinematics after total knee arthroplasty.

Authors:  M K Harman; S A Banks; W A Hodge
Journal:  Clin Orthop Relat Res       Date:  2001-11       Impact factor: 4.176

7.  Observations of femoral rollback in cruciate-retaining knee arthroplasty.

Authors:  Hiroyuki Nozaki; Scott A Banks; Tohru Suguro; W Andrew Hodge
Journal:  Clin Orthop Relat Res       Date:  2002-11       Impact factor: 4.176

8.  Insall Award paper. Why are total knee arthroplasties failing today?

Authors:  Peter F Sharkey; William J Hozack; Richard H Rothman; Shani Shastri; Sidney M Jacoby
Journal:  Clin Orthop Relat Res       Date:  2002-11       Impact factor: 4.176

Review 9.  The use of functional analysis in evaluating knee kinematics.

Authors:  Thomas P Andriacchi; Chris O Dyrby; Todd S Johnson
Journal:  Clin Orthop Relat Res       Date:  2003-05       Impact factor: 4.176

10.  A direct comparison of patient and force-controlled simulator total knee replacement kinematics.

Authors:  John D DesJardins; Scott A Banks; Lisa C Benson; Thomas Pace; Martine LaBerge
Journal:  J Biomech       Date:  2007-07-12       Impact factor: 2.712

View more
  15 in total

1.  Measurement of in vivo anterior cruciate ligament strain during dynamic jump landing.

Authors:  K A Taylor; M E Terry; G M Utturkar; C E Spritzer; R M Queen; L A Irribarra; W E Garrett; L E DeFrate
Journal:  J Biomech       Date:  2010-11-18       Impact factor: 2.712

2.  The effect of geometric variations in posterior-stabilized knee designs on motion characteristics measured in a knee loading machine.

Authors:  Peter S Walker; Michael T Lowry; Anoop Kumar
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

3.  Finite element evaluation of the newest ISO testing standard for polyethylene total knee replacement liners.

Authors:  Steven P Mell; Spencer Fullam; Markus A Wimmer; Hannah J Lundberg
Journal:  Proc Inst Mech Eng H       Date:  2018-04-15       Impact factor: 1.617

Review 4.  [Implant wear and aseptic loosening. An overview].

Authors:  C Kaddick; I Catelas; P H Pennekamp; M A Wimmer
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

5.  Navigation-based femorotibial rotation pattern correlated with flexion angle after total knee arthroplasty.

Authors:  Kazunari Ishida; Nao Shibanuma; Tomoyuki Matsumoto; Hiroshi Sasaki; Koji Takayama; Tokio Matsuzaki; Katsumasa Tei; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-27       Impact factor: 4.342

Review 6.  Gait analysis methodology for the measurement of biomechanical parameters in total knee arthroplasties. A literature review.

Authors:  Georgios I Papagiannis; Athanasios I Triantafyllou; Ilias M Roumpelakis; Panayiotis J Papagelopoulos; George C Babis
Journal:  J Orthop       Date:  2018-02-02

7.  Comparison of ISO standard and TKR patient axial force profiles during the stance phase of gait.

Authors:  Hannah J Lundberg; Valentina Ngai; Markus A Wimmer
Journal:  Proc Inst Mech Eng H       Date:  2012-03       Impact factor: 1.617

8.  Factors affecting intraoperative kinematic patterns and flexion angles in navigated total knee arthroplasty.

Authors:  Kazunari Ishida; Nao Shibanuma; Tomoyuki Matsumoto; Hiroshi Sasaki; Koji Takayama; Akihiko Toda; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-03-13       Impact factor: 4.342

9.  Fine tuning total knee replacement contact force prediction algorithms using blinded model validation.

Authors:  Hannah J Lundberg; Christopher Knowlton; Markus A Wimmer
Journal:  J Biomech Eng       Date:  2013-02       Impact factor: 2.097

Review 10.  Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms.

Authors:  J Gallo; S B Goodman; Y T Konttinen; M A Wimmer; M Holinka
Journal:  Acta Biomater       Date:  2013-05-10       Impact factor: 8.947

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.