Literature DB >> 12439231

Insall Award paper. Why are total knee arthroplasties failing today?

Peter F Sharkey1, William J Hozack, Richard H Rothman, Shani Shastri, Sidney M Jacoby.   

Abstract

The incidence of failure after knee replacement is low, yet it has been reported that more than 22,000 knee replacements are revised yearly. The purpose of the current study was to determine current mechanisms of failure of total knee arthroplasties. A retrospective review was done on all patients who had revision total knee arthroplasty during a 3-year period (September 1997-October 2000) at one institution. The preoperative evaluation in conjunction with radiographs, laboratory data, and intraoperative findings were used to determine causes of failure. Two hundred twelve surgeries were done on 203 patients (nine patients had bilateral surgeries). The reasons for failure listed in order of prevalence among the patients in this study include polyethylene wear, aseptic loosening, instability, infection, arthrofibrosis, malalignment or malposition, deficient extensor mechanism, avascular necrosis in the patella, periprosthetic fracture, and isolated patellar resurfacing. The cases reviewed included patients who had revision surgery within 9 days to 28 years (average, 3.7 years) after the previous surgery. More than half of the revisions in this group of patients were done less than 2 years after the index operation. Fifty percent of early revision total knee arthroplasties in this series were related to instability, malalignment or malposition, and failure of fixation.

Entities:  

Mesh:

Year:  2002        PMID: 12439231     DOI: 10.1097/00003086-200211000-00003

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  313 in total

1.  Introducing a knee endoprosthesis model increases risk of early revision surgery.

Authors:  Mikko Peltola; Antti Malmivaara; Mika Paavola
Journal:  Clin Orthop Relat Res       Date:  2011-12-09       Impact factor: 4.176

2.  Revision total knee arthroplasty: a comparison of postoperative leg alignment after computer-assisted implantation versus the conventional technique.

Authors:  Lars Perlick; Holger Bäthis; Carsten Perlick; Christian Lüring; Markus Tingart; Joachim Grifka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-04-08       Impact factor: 4.342

3.  Soft tissue balance using the tibia first gap technique with navigation system in cruciate-retaining total knee arthroplasty.

Authors:  Tomoyuki Matsumoto; Hirotsugu Muratsu; Seiji Kubo; Takehiko Matsushita; Kazunari Ishida; Hirosi Sasaki; Shinya Oka; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Int Orthop       Date:  2011-10-27       Impact factor: 3.075

4.  Intraoperative assessment of resected condyle thickness in total knee arthroplasty.

Authors:  Dae Kyung Bae; Sang Jun Song; Kyoung Ho Yoon; Jung Ho Noh; Chul Hee Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-12-24       Impact factor: 4.342

5.  Knee wear measured in retrievals: a polished tray reduces insert wear.

Authors:  Daniel J Berry; John H Currier; Michael B Mayor; John P Collier
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

6.  Surface damage versus tibial polyethylene insert conformity: a retrieval study.

Authors:  Markus A Wimmer; Michel P Laurent; Jeannie D Haman; Joshua J Jacobs; Jorge O Galante
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

7.  [Soft tissue balanced navigation of total knee arthroplasties].

Authors:  C Schnurr; I Stolzenberg; J Nessler; P Eysel; P König
Journal:  Oper Orthop Traumatol       Date:  2012-04       Impact factor: 1.154

8.  What are the causes of revision total knee arthroplasty in Japan?

Authors:  Yasuhiko Kasahara; Tokifumi Majima; Shoichi Kimura; Osamu Nishiike; Jun Uchida
Journal:  Clin Orthop Relat Res       Date:  2013-05       Impact factor: 4.176

Review 9.  Current concepts and future perspectives in computer-assisted navigated total knee replacement.

Authors:  Tomoyuki Matsumoto; Naoki Nakano; John E Lawrence; Vikas Khanduja
Journal:  Int Orthop       Date:  2018-05-12       Impact factor: 3.075

10.  Radiographic parameters improve lower extremity prosthetic alignment.

Authors:  Ryan Mooney; Patrick Carry; Erin Wylie; Abby Schultz; Bryan McNair; Carol Page; Susan Biffl; Travis Heare
Journal:  J Child Orthop       Date:  2013-09-28       Impact factor: 1.548

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.