Literature DB >> 19638842

Role of computed tomography voxel size in detection and discrimination of calcium and iron deposits in atherosclerotic human coronary artery specimens.

Alexander C Langheinrich1, Marian Kampschulte, Christine Crössmann, Regina Moritz, Wigbert S Rau, Rainer M Bohle, Erik L Ritman.   

Abstract

OBJECTIVE: This study evaluated the influence of voxel size on its ability to discriminate calcium from iron deposits in ex vivo coronary arteries.
METHODS: Postmortem human coronary arteries underwent multislice computed tomographic scan at (600-microm) voxel size to provide an index of computed tomography (CT) image noise and synchrotron-based micro-CT at (4-microm) voxel size to provide data for generating a range of voxel sizes 4 to (600-microm) after grayscale noise was added to the projection images before reconstruction so as to mimic the effect of retaining the same radiation exposure involved in the multislice computed tomographic scan.
RESULTS: At voxel sizes of (20-microm) or smaller, iron deposits could be identified based on CT grayscale value. Voxels of (100-microm) or larger cannot resolve nor distinguish iron deposits from calcifications by virtue of CT grayscale value.
CONCLUSIONS: Clinical CT scanners cannot be expected to discriminate iron deposits from calcifications by their CT value alone in the arterial wall.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19638842      PMCID: PMC2743385          DOI: 10.1097/RCT.0b013e318194c0a2

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  18 in total

1.  Unstable coronary-artery plaques.

Authors:  Donald D Heistad
Journal:  N Engl J Med       Date:  2003-12-11       Impact factor: 91.245

2.  Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot.

Authors:  T G Flohr; K Stierstorfer; S Ulzheimer; H Bruder; A N Primak; C H McCollough
Journal:  Med Phys       Date:  2005-08       Impact factor: 4.071

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  Electron, proton and photon induced X-ray microprobes: analytic sensitivity versus spatial resolution.

Authors:  L Grodzins
Journal:  Neurotoxicology       Date:  1983       Impact factor: 4.294

Review 5.  Atherosclerotic plaque progression and vulnerability to rupture: angiogenesis as a source of intraplaque hemorrhage.

Authors:  Renu Virmani; Frank D Kolodgie; Allen P Burke; Aloke V Finn; Herman K Gold; Thomas N Tulenko; Steven P Wrenn; Jagat Narula
Journal:  Arterioscler Thromb Vasc Biol       Date:  2005-07-21       Impact factor: 8.311

6.  Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Stephanie Busch; Alexander W Leber; Alexander Becker; Bernd J Wintersperger; Carsten Rist; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Invest Radiol       Date:  2007-10       Impact factor: 6.016

Review 7.  Assessment of coronary arteries with CT.

Authors:  Christoph R Becker
Journal:  Radiol Clin North Am       Date:  2002-07       Impact factor: 2.303

Review 8.  Pathophysiology of acute myocardial infarction.

Authors:  Allen P Burke; Renu Virmani
Journal:  Med Clin North Am       Date:  2007-07       Impact factor: 5.456

9.  Quantitative X-ray imaging of intraplaque hemorrhage in aortas of apoE(-/-)/LDL(-/-) double knockout mice.

Authors:  Alexander C Langheinrich; Agata Michniewicz; Daniel G Sedding; Barry Lai; Steven M Jorgensen; Rainer M Bohle; Erik L Ritman
Journal:  Invest Radiol       Date:  2007-05       Impact factor: 6.016

Review 10.  Biomarkers of atherosclerosis and the potential of MRI for the diagnosis of vulnerable plaque.

Authors:  E Canet-Soulas; D Letourneur
Journal:  MAGMA       Date:  2007-06-29       Impact factor: 2.310

View more
  7 in total

1.  A mechanistic analysis of the role of microcalcifications in atherosclerotic plaque stability: potential implications for plaque rupture.

Authors:  Natalia Maldonado; Adreanne Kelly-Arnold; Yuliya Vengrenyuk; Damien Laudier; John T Fallon; Renu Virmani; Luis Cardoso; Sheldon Weinbaum
Journal:  Am J Physiol Heart Circ Physiol       Date:  2012-07-09       Impact factor: 4.733

2.  Dual energy computed tomography quantification of carotid plaques calcification: comparison between monochromatic and polychromatic energies with pathology correlation.

Authors:  Lorenzo Mannelli; Lawrence MacDonald; Marcello Mancini; Marina Ferguson; William P Shuman; Monica Ragucci; Serena Monti; Dongxiang Xu; Chun Yuan; Lee M Mitsumori
Journal:  Eur Radiol       Date:  2014-12-24       Impact factor: 5.315

3.  Spectral CT of carotid atherosclerotic plaque: comparison with histology.

Authors:  R Zainon; J P Ronaldson; T Janmale; N J Scott; T M Buckenham; A P H Butler; P H Butler; R M Doesburg; S P Gieseg; J A Roake; N G Anderson
Journal:  Eur Radiol       Date:  2012-07-04       Impact factor: 5.315

4.  Small calcified coronary atherosclerotic plaque simulation model: minimal size and attenuation detectable by 64-MDCT and MicroCT.

Authors:  Wisnumurti Kristanto; Peter M A van Ooijen; Jaap M Groen; Rozemarijn Vliegenthart; Matthijs Oudkerk
Journal:  Int J Cardiovasc Imaging       Date:  2011-04-21       Impact factor: 2.357

5.  Changes in measured size of atherosclerotic plaque calcifications in dual-energy CT of ex vivo carotid endarterectomy specimens: effect of monochromatic keV image reconstructions.

Authors:  Lorenzo Mannelli; Lee M Mitsumori; Marina Ferguson; Dongxiang Xu; Baocheng Chu; Kelley R Branch; William P Shuman; Chun Yuan
Journal:  Eur Radiol       Date:  2012-08-21       Impact factor: 5.315

6.  Noise Power Characteristics of a Micro-Computed Tomography System.

Authors:  Muhammad U Ghani; Liqiang Ren; Molly Wong; Yuhua Li; Bin Zheng; Xiujiang John Rong; Kai Yang; Hong Liu
Journal:  J Comput Assist Tomogr       Date:  2017-01       Impact factor: 1.826

7.  Characterising human atherosclerotic carotid plaque tissue composition and morphology using combined spectroscopic and imaging modalities.

Authors:  Hilary E Barrett; John J Mulvihill; Eoghan M Cunnane; Michael T Walsh
Journal:  Biomed Eng Online       Date:  2015-01-09       Impact factor: 2.819

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.