Literature DB >> 19620177

A novel algorithm for the morphometric assessment of radiotherapy treatment planning volumes.

R Jena1, N F Kirkby, K E Burton, A C F Hoole, L T Tan, N G Burnet.   

Abstract

Quantitative assessment of target volume contouring in radiotherapy treatment planning is an important aspect of quality assessment and educational exercises. The Conformity Index (CI) is a volume-based statistic frequently used for this purpose. Although the CI is relatively simple to understand and can be calculated using most treatment planning systems, it does not provide any information on the differences in shape between the two volumes. We present a new morphometric (shape-based) statistic known as the "mean distance to conformity" (MDC). For a specific volume that is being evaluated against a reference volume, the MDC represents the average distance that all outlying points in the volume must be moved in order to achieve perfect conformity with the reference volume. The MDC comprises a component related to under-contouring (where the evaluation volume is smaller than the reference volume) and a component related to over-contouring (where the evaluation extends beyond the reference volume). Furthermore, voxel-by-voxel information on conformity errors can also be displayed using a volume-error histogram. Calculation of MDC statistics is achieved using a three-dimensional grid search algorithm. By using a range of scenarios comprising both theoretical and actual clinical volumes, we demonstrate the increased utility of the MDC for the detection of contouring errors.

Mesh:

Year:  2009        PMID: 19620177      PMCID: PMC3487247          DOI: 10.1259/bjr/27674581

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  13 in total

Review 1.  [Conformal index and radiotherapy].

Authors:  L Feuvret; G Noël; C Nauraye; P Garcia; J J-Mazeron
Journal:  Cancer Radiother       Date:  2004-04       Impact factor: 1.018

2.  Organ contouring for prostate cancer: interobserver and internal organ motion variability.

Authors:  X Gual-Arnau; M V Ibáñez-Gual; F Lliso; S Roldán
Journal:  Comput Med Imaging Graph       Date:  2005-11-04       Impact factor: 4.790

3.  Performance of user independent echocardiographic border detection algorithm: comparison with human observer variability.

Authors:  Florence H Sheehan; Edward A Geiser; Brad Munt; Catherine M Otto
Journal:  Int J Cardiovasc Imaging       Date:  2005-12       Impact factor: 2.357

4.  Intraobserver and interobserver variability in GTV delineation on FDG-PET-CT images of head and neck cancers.

Authors:  Stephen L Breen; Julia Publicover; Shiroma De Silva; Greg Pond; Kristy Brock; Brian O'Sullivan; Bernard Cummings; Laura Dawson; Anne Keller; John Kim; Jolie Ringash; Eugene Yu; Aaron Hendler; John Waldron
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-03-26       Impact factor: 7.038

5.  A general methodology for three-dimensional analysis of variation in target volume delineation.

Authors:  P Remeijer; C Rasch; J V Lebesque; M van Herk
Journal:  Med Phys       Date:  1999-06       Impact factor: 4.071

6.  Reduction of observer variation using matched CT-PET for lung cancer delineation: a three-dimensional analysis.

Authors:  Roel J H M Steenbakkers; Joop C Duppen; Isabelle Fitton; Kirsten E I Deurloo; Lambert J Zijp; Emile F I Comans; Apollonia L J Uitterhoeve; Patrick T R Rodrigus; Gijsbert W P Kramer; Johan Bussink; Katrien De Jaeger; José S A Belderbos; Peter J C M Nowak; Marcel van Herk; Coen R N Rasch
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-09-28       Impact factor: 7.038

7.  Prostate contouring uncertainty in megavoltage computed tomography images acquired with a helical tomotherapy unit during image-guided radiation therapy.

Authors:  William Y Song; Bernard Chiu; Glenn S Bauman; Michael Lock; George Rodrigues; Robert Ash; Craig Lewis; Aaron Fenster; Jerry J Battista; Jake Van Dyk
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-06-01       Impact factor: 7.038

8.  Comparison of human and automatic segmentations of kidneys from CT images.

Authors:  Manjori Rao; Joshua Stough; Yueh-Yun Chi; Keith Muller; Gregg Tracton; Stephen M Pizer; Edward L Chaney
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-03-01       Impact factor: 7.038

9.  Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy.

Authors:  Kirsten E I Deurloo; Roel J H M Steenbakkers; Lambert J Zijp; Josien A de Bois; Peter J C M Nowak; Coen R N Rasch; Marcel van Herk
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-01-01       Impact factor: 7.038

10.  Target volume delineation for partial breast radiotherapy planning: clinical characteristics associated with low interobserver concordance.

Authors:  Ross P Petersen; Pauline T Truong; Hosam A Kader; Eric Berthelet; Junella C Lee; Michelle L Hilts; Adam S Kader; Wayne A Beckham; Ivo A Olivotto
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-09-01       Impact factor: 7.038

View more
  16 in total

Review 1.  Improving radiotherapy quality assurance in clinical trials: assessment of target volume delineation of the pre-accrual benchmark case.

Authors:  S Gwynne; E Spezi; D Sebag-Montefiore; S Mukherjee; E Miles; J Conibear; J Staffurth
Journal:  Br J Radiol       Date:  2013-02-07       Impact factor: 3.039

2.  The utility of atlas-assisted segmentation in the male pelvis is dependent on the interobserver agreement of the structures segmented.

Authors:  K A Langmack; C Perry; C Sinstead; J Mills; D Saunders
Journal:  Br J Radiol       Date:  2014-08-29       Impact factor: 3.039

3.  Prospective randomized double-blind pilot study of site-specific consensus atlas implementation for rectal cancer target volume delineation in the cooperative group setting.

Authors:  Clifton D Fuller; Jasper Nijkamp; Joop C Duppen; Coen R N Rasch; Charles R Thomas; Samuel J Wang; Paul Okunieff; William E Jones; Daniel Baseman; Shilpen Patel; Carlo G N Demandante; Anna M Harris; Benjamin D Smith; Alan W Katz; Camille McGann; Jennifer L Harper; Daniel T Chang; Stephen Smalley; David T Marshall; Karyn A Goodman; Niko Papanikolaou; Lisa A Kachnic
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-04-18       Impact factor: 7.038

4.  Random variation in rectal position during radiotherapy for prostate cancer is two to three times greater than that predicted from prostate motion.

Authors:  J Scaife; K Harrison; M Romanchikova; A Parker; M Sutcliffe; S Bond; S Thomas; S Freeman; R Jena; A Bates; N Burnet
Journal:  Br J Radiol       Date:  2014-08-20       Impact factor: 3.039

5.  Validation of a dose warping algorithm using clinically realistic scenarios.

Authors:  Y G Roussakis; H Dehghani; S Green; G J Webster
Journal:  Br J Radiol       Date:  2015-03-20       Impact factor: 3.039

6.  Comparison of investigator-delineated gross tumour volumes and quality assurance in pancreatic cancer: Analysis of the on-trial cases for the SCALOP trial.

Authors:  Emmanouil Fokas; Emiliano Spezi; Neel Patel; Chris Hurt; Lisette Nixon; Kwun-Ye Chu; John Staffurth; Ross Abrams; Somnath Mukherjee
Journal:  Radiother Oncol       Date:  2016-08-03       Impact factor: 6.280

7.  The influence of dose distribution on treatment outcome in the SCOPE 1 oesophageal cancer trial.

Authors:  Rhys Carrington; Emiliano Spezi; Sarah Gwynne; Peter Dutton; Chris Hurt; John Staffurth; Thomas Crosby
Journal:  Radiat Oncol       Date:  2016-02-06       Impact factor: 3.481

8.  Distance deviation measure of contouring variability.

Authors:  Peter Rogelj; Robert Hudej; Primoz Petric
Journal:  Radiol Oncol       Date:  2013-02-01       Impact factor: 2.991

9.  Multimodality imaging with CT, MR and FDG-PET for radiotherapy target volume delineation in oropharyngeal squamous cell carcinoma.

Authors:  David Bird; Andrew F Scarsbrook; Jonathan Sykes; Satiavani Ramasamy; Manil Subesinghe; Brendan Carey; Daniel J Wilson; Neil Roberts; Gary McDermott; Ebru Karakaya; Evrim Bayman; Mehmet Sen; Richard Speight; Robin J D Prestwich
Journal:  BMC Cancer       Date:  2015-11-04       Impact factor: 4.430

10.  The feasibility of atlas-based automatic segmentation of MRI for H&N radiotherapy planning.

Authors:  Kieran Wardman; Robin J D Prestwich; Mark J Gooding; Richard J Speight
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

View more