Literature DB >> 15132144

[Conformal index and radiotherapy].

L Feuvret1, G Noël, C Nauraye, P Garcia, J J-Mazeron.   

Abstract

Goal of radiotherapy is to treat patient with the best therapeutic ratio, i.e. the highest local control and the lowest toxicity rates. The conformal approach, three-dimensional conformal radiotherapy or intensity-modulated radiotherapy, is based on imageries, up-dated 3-D treatment planning systems, immobilization systems, restricted quality assurance and treatment verification. The aim is to ensure a high dose distribution tailored to the limits of the target volume, while reducing exposure of normal tissues. The evaluation tools used for optimizing treatment are the visual inspection of the dose distribution in various planes, and the dose-volume histograms, but they do not fully quantify the conformity of dose distributions. The conformal index is a tool for scoring a given plan or for evaluating different treatment plans for the same patient. This paper describes the onset and evolution of conformal index and his potential application field.

Entities:  

Mesh:

Year:  2004        PMID: 15132144     DOI: 10.1016/j.canrad.2003.12.002

Source DB:  PubMed          Journal:  Cancer Radiother        ISSN: 1278-3218            Impact factor:   1.018


  5 in total

1.  Dosimetric comparison of free-breathing and deep inspiration breath-hold radiotherapy for lung cancer.

Authors:  V Marchand; S Zefkili; J Desrousseaux; L Simon; C Dauphinot; P Giraud
Journal:  Strahlenther Onkol       Date:  2012-05-17       Impact factor: 3.621

2.  Magnetic Resonance Imaging Evaluation of Hepatocellular Carcinoma Treated With Stereotactic Body Radiation Therapy: Long Term Imaging Follow-Up.

Authors:  Mishal Mendiratta-Lala; William Masch; Prasad R Shankar; Holly E Hartman; Matthew S Davenport; Matthew J Schipper; Chris Maurino; Kyle C Cuneo; Theodore S Lawrence; Dawn Owen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-09-10       Impact factor: 7.038

3.  A novel algorithm for the morphometric assessment of radiotherapy treatment planning volumes.

Authors:  R Jena; N F Kirkby; K E Burton; A C F Hoole; L T Tan; N G Burnet
Journal:  Br J Radiol       Date:  2009-07-20       Impact factor: 3.039

4.  Defining the Optimal Time of Adaptive Replanning in Prostate Cancer Patients with Weight Change during Volumetric Arc Radiotherapy: A Dosimetric and Mathematical Analysis Using the Gamma Index.

Authors:  Hoon Sik Choi; Guang Sub Jo; Jong Pyo Chae; Sang Bong Lee; Chul Hang Kim; Bae Kwon Jeong; Hojin Jeong; Yun Hee Lee; In Bong Ha; Ki Mun Kang; Jin Ho Song
Journal:  Comput Math Methods Med       Date:  2017-12-18       Impact factor: 2.238

5.  Image-based response assessment of liver metastases following stereotactic body radiotherapy with respiratory tracking.

Authors:  Hajer Jarraya; Xavier Mirabel; Sophie Taieb; Sylvain Dewas; Emmanuelle Tresch; Francois Bonodeau; Antoine Adenis; Andrew Kramar; Eric Lartigau; Luc Ceugnart
Journal:  Radiat Oncol       Date:  2013-01-30       Impact factor: 3.481

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.