Literature DB >> 15708280

Comparison of human and automatic segmentations of kidneys from CT images.

Manjori Rao1, Joshua Stough, Yueh-Yun Chi, Keith Muller, Gregg Tracton, Stephen M Pizer, Edward L Chaney.   

Abstract

PURPOSE: A controlled observer study was conducted to compare a method for automatic image segmentation with conventional user-guided segmentation of right and left kidneys from planning computerized tomographic (CT) images. METHODS AND MATERIALS: Deformable shape models called m-reps were used to automatically segment right and left kidneys from 12 target CT images, and the results were compared with careful manual segmentations performed by two human experts. M-rep models were trained based on manual segmentations from a collection of images that did not include the targets. Segmentation using m-reps began with interactive initialization to position the kidney model over the target kidney in the image data. Fully automatic segmentation proceeded through two stages at successively smaller spatial scales. At the first stage, a global similarity transformation of the kidney model was computed to position the model closer to the target kidney. The similarity transformation was followed by large-scale deformations based on principal geodesic analysis (PGA). During the second stage, the medial atoms comprising the m-rep model were deformed one by one. This procedure was iterated until no changes were observed. The transformations and deformations at both stages were driven by optimizing an objective function with two terms. One term penalized the currently deformed m-rep by an amount proportional to its deviation from the mean m-rep derived from PGA of the training segmentations. The second term computed a model-to-image match term based on the goodness of match of the trained intensity template for the currently deformed m-rep with the corresponding intensity data in the target image. Human and m-rep segmentations were compared using quantitative metrics provided in a toolset called Valmet. Metrics reported in this article include (1) percent volume overlap; (2) mean surface distance between two segmentations; and (3) maximum surface separation (Hausdorff distance).
RESULTS: Averaged over all kidneys the mean surface separation was 0.12 cm, the mean Hausdorff distance was 0.99 cm, and the mean volume overlap for human segmentations was 88.8%. Between human and m-rep segmentations the mean surface separation was 0.18-0.19 cm, the mean Hausdorff distance was 1.14-1.25 cm, and the mean volume overlap was 82-83%.
CONCLUSIONS: Overall in this study, the best m-rep kidney segmentations were at least as good as careful manual slice-by-slice segmentations performed by two experienced humans, and the worst performance was no worse than typical segmentations from our clinical setting. The mean surface separations for human-m-rep segmentations were slightly larger than for human-human segmentations but still in the subvoxel range, and volume overlap and maximum surface separation were slightly better for human-human comparisons. These results were expected because of experimental factors that favored comparison of the human-human segmentations. In particular, m-rep agreement with humans appears to have been limited largely by fundamental differences between manual slice-by-slice and true three-dimensional segmentation, imaging artifacts, image voxel dimensions, and the use of an m-rep model that produced a smooth surface across the renal pelvis.

Entities:  

Mesh:

Year:  2005        PMID: 15708280     DOI: 10.1016/j.ijrobp.2004.11.014

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  20 in total

1.  Development of a semi-automated method for mitral valve modeling with medial axis representation using 3D ultrasound.

Authors:  Alison M Pouch; Paul A Yushkevich; Benjamin M Jackson; Arminder S Jassar; Mathieu Vergnat; Joseph H Gorman; Robert C Gorman; Chandra M Sehgal
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

2.  Validation of phalanx bone three-dimensional surface segmentation from computed tomography images using laser scanning.

Authors:  Nicole A DeVries; Esther E Gassman; Nicole A Kallemeyn; Kiran H Shivanna; Vincent A Magnotta; Nicole M Grosland
Journal:  Skeletal Radiol       Date:  2007-10-25       Impact factor: 2.199

3.  Continuous medial representation of brain structures using the biharmonic PDE.

Authors:  Paul A Yushkevich
Journal:  Neuroimage       Date:  2008-11-12       Impact factor: 6.556

4.  Two-Step Hypothesis Testing When the Number of Variables Exceeds the Sample Size.

Authors:  Yueh-Yun Chi; Keith E Muller
Journal:  Commun Stat Simul Comput       Date:  2013       Impact factor: 1.118

5.  A novel algorithm for the morphometric assessment of radiotherapy treatment planning volumes.

Authors:  R Jena; N F Kirkby; K E Burton; A C F Hoole; L T Tan; N G Burnet
Journal:  Br J Radiol       Date:  2009-07-20       Impact factor: 3.039

6.  Effect of various environments and computed tomography scanning parameters on renal volume measurements in vitro: A phantom study.

Authors:  Wangyan Liu; Yinsu Zhu; Lijun Tang; Xiaomei Zhu; Yi Xu; Guanyu Yang
Journal:  Exp Ther Med       Date:  2016-06-01       Impact factor: 2.447

7.  Using scientifically and statistically sufficient statistics in comparing image segmentations.

Authors:  Yueh-Yun Chi; Keith E Muller
Journal:  Stat Interface       Date:  2010-01-01       Impact factor: 0.582

8.  Renal Tumor Quantification and Classification in Contrast-Enhanced Abdominal CT.

Authors:  Marius George Linguraru; Jianhua Yao; Rabindra Gautam; James Peterson; Zhixi Li; W Marston Linehan; Ronald M Summers
Journal:  Pattern Recognit       Date:  2009-06-01       Impact factor: 7.740

9.  Interactive semiautomatic contour delineation using statistical conditional random fields framework.

Authors:  Yu-Chi Hu; Michael D Grossberg; Abraham Wu; Nadeem Riaz; Carmen Perez; Gig S Mageras
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

10.  Fully automatic segmentation of the femur from 3D-CT images using primitive shape recognition and statistical shape models.

Authors:  Lassad Ben Younes; Yoshikazu Nakajima; Toki Saito
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-10-08       Impact factor: 2.924

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.