Literature DB >> 19602729

Chronic stability and selectivity of four-contact spiral nerve-cuff electrodes in stimulating the human femoral nerve.

L E Fisher1, D J Tyler, J S Anderson, R J Triolo.   

Abstract

This study describes the stability and selectivity of four-contact spiral nerve-cuff electrodes implanted bilaterally on distal branches of the femoral nerves of a human volunteer with spinal cord injury as part of a neuroprosthesis for standing and transfers. Stimulation charge threshold, the minimum charge required to elicit a visible muscle contraction, was consistent and low (mean threshold charge at 63 weeks post-implantation: 23.3 +/- 8.5 nC) for all nerve-cuff electrode contacts over 63 weeks after implantation, indicating a stable interface with the peripheral nervous system. The ability of individual nerve-cuff electrode contacts to selectively stimulate separate components of the femoral nerve to activate individual heads of the quadriceps was assessed with fine-wire intramuscular electromyography while measuring isometric twitch knee extension moment. Six of eight electrode contacts could selectively activate one head of the quadriceps while selectively excluding others to produce maximum twitch responses of between 3.8 and 8.1 N m. The relationship between isometric twitch and tetanic knee extension moment was quantified, and selective twitch muscle responses scaled to between 15 and 35 N m in tetanic response to pulse trains with similar stimulation parameters. These results suggest that this nerve-cuff electrode can be an effective and chronically stable tool for selectively stimulating distal nerve branches in the lower extremities for neuroprosthetic applications.

Entities:  

Mesh:

Year:  2009        PMID: 19602729      PMCID: PMC2928075          DOI: 10.1088/1741-2560/6/4/046010

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  33 in total

1.  Clinical experience with a helical bipolar stimulating lead.

Authors:  W B Tarver; R E George; S E Maschino; L K Holder; J F Wernicke
Journal:  Pacing Clin Electrophysiol       Date:  1992-10       Impact factor: 1.976

2.  The effects of armrests and high seat heights on lower-limb joint load and muscular activity during sitting and rising.

Authors:  U P Arborelius; P Wretenberg; F Lindberg
Journal:  Ergonomics       Date:  1992-11       Impact factor: 2.778

3.  Selective and independent activation of four motor fascicles using a four contact nerve-cuff electrode.

Authors:  Matthew D Tarler; J Thomas Mortimer
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2004-06       Impact factor: 3.802

4.  A nerve cuff technique for selective excitation of peripheral nerve trunk regions.

Authors:  J D Sweeney; D A Ksienski; J T Mortimer
Journal:  IEEE Trans Biomed Eng       Date:  1990-07       Impact factor: 4.538

5.  Methods for estimating isometric recruitment curves of electrically stimulated muscle.

Authors:  W K Durfee; K E MacLean
Journal:  IEEE Trans Biomed Eng       Date:  1989-07       Impact factor: 4.538

6.  A spiral nerve cuff electrode for peripheral nerve stimulation.

Authors:  G G Naples; J T Mortimer; A Scheiner; J D Sweeney
Journal:  IEEE Trans Biomed Eng       Date:  1988-11       Impact factor: 4.538

7.  The influence of chair height on lower limb mechanics during rising.

Authors:  M W Rodosky; T P Andriacchi; G B Andersson
Journal:  J Orthop Res       Date:  1989       Impact factor: 3.494

8.  An analysis of sit-to-stand movements.

Authors:  T Kotake; N Dohi; T Kajiwara; N Sumi; Y Koyama; T Miura
Journal:  Arch Phys Med Rehabil       Date:  1993-10       Impact factor: 3.966

9.  Standing-up of a healthy subject and a paraplegic patient.

Authors:  T Bajd; A Kralj; R Turk
Journal:  J Biomech       Date:  1982       Impact factor: 2.712

10.  Performance of epimysial stimulating electrodes in the lower extremities of individuals with spinal cord injury.

Authors:  James P Uhlir; Ronald J Triolo; John A Davis; Carol Bieri
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2004-06       Impact factor: 3.802

View more
  34 in total

Review 1.  Neural interfaces for somatosensory feedback: bringing life to a prosthesis.

Authors:  Dustin J Tyler
Journal:  Curr Opin Neurol       Date:  2015-12       Impact factor: 5.710

2.  Sensory feedback by peripheral nerve stimulation improves task performance in individuals with upper limb loss using a myoelectric prosthesis.

Authors:  Matthew Schiefer; Daniel Tan; Steven M Sidek; Dustin J Tyler
Journal:  J Neural Eng       Date:  2015-12-08       Impact factor: 5.379

Review 3.  Implantable neurotechnologies: electrical stimulation and applications.

Authors:  Sudip Nag; Nitish V Thakor
Journal:  Med Biol Eng Comput       Date:  2016-01-11       Impact factor: 2.602

Review 4.  Restoring standing capabilities with feedback control of functional neuromuscular stimulation following spinal cord injury.

Authors:  Raviraj Nataraj; Musa L Audu; Ronald J Triolo
Journal:  Med Eng Phys       Date:  2017-02-15       Impact factor: 2.242

5.  Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees.

Authors:  Daniel W Tan; Matthew A Schiefer; Michael W Keith; J Robert Anderson; Dustin J Tyler
Journal:  J Neural Eng       Date:  2015-01-28       Impact factor: 5.379

6.  Rodent model for assessing the long term safety and performance of peripheral nerve recording electrodes.

Authors:  Srikanth Vasudevan; Kunal Patel; Cristin Welle
Journal:  J Neural Eng       Date:  2016-12-09       Impact factor: 5.379

7.  Continuous Direct Current Nerve Block Using Multi Contact High Capacitance Electrodes.

Authors:  Tina Vrabec; Niloy Bhadra; Gustaf Van Acker; Narendra Bhadra; Kevin Kilgore
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2016-07-09       Impact factor: 3.802

8.  Microstimulation of the lumbar DRG recruits primary afferent neurons in localized regions of lower limb.

Authors:  Christopher A Ayers; Lee E Fisher; Robert A Gaunt; Douglas J Weber
Journal:  J Neurophysiol       Date:  2016-04-06       Impact factor: 2.714

9.  A novel flexible cuff-like microelectrode for dual purpose, acute and chronic electrical interfacing with the mouse cervical vagus nerve.

Authors:  A S Caravaca; T Tsaava; L Goldman; H Silverman; G Riggott; S S Chavan; C Bouton; K J Tracey; R Desimone; E S Boyden; H S Sohal; P S Olofsson
Journal:  J Neural Eng       Date:  2017-12       Impact factor: 5.379

10.  Intraoperative evaluation of the spiral nerve cuff electrode on the femoral nerve trunk.

Authors:  K H Polasek; M A Schiefer; G C J Pinault; R J Triolo; D J Tyler
Journal:  J Neural Eng       Date:  2009-11-09       Impact factor: 5.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.