Literature DB >> 7061523

Standing-up of a healthy subject and a paraplegic patient.

T Bajd, A Kralj, R Turk.   

Abstract

The joint torques in hip, knee and ankle were measured during the standing-up of a healthy subject. Force plate and stroboscopic photography were used in the experiment. It has been observed that the time courses of particular joint torques depend on the kind of standing-up. On the basis of these results a standing-up procedure for paraplegic patients was proposed. With the use of electrical stimulation to both paralyzed knee extensors and through use of the arm support, a completely paraplegic patient was able to rise independently from the wheel-chair. The same dual-channel stimulation also provides knee locking during standing of spinal cord injured patients.

Entities:  

Mesh:

Year:  1982        PMID: 7061523     DOI: 10.1016/0021-9290(82)90029-x

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  10 in total

1.  Properties of implanted electrodes for functional electrical stimulation.

Authors:  D Popovic; T Gordon; V F Rafuse; A Prochazka
Journal:  Ann Biomed Eng       Date:  1991       Impact factor: 3.934

2.  The influence of initial posture on the sit-to-stand movement.

Authors:  C Stevens; F Bojsen-Møller; R W Soames
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1989

3.  Quantitative weightbearing and gait evaluation of paraplegics using functional electrical stimulation.

Authors:  J Mizrahi; Z Braun; T Najenson; D Graupe
Journal:  Med Biol Eng Comput       Date:  1985-03       Impact factor: 2.602

4.  Model-based development of neuroprosthesis for paraplegic patients.

Authors:  R Riener
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1999-05-29       Impact factor: 6.237

5.  Longitudinal performance of a surgically implanted neuroprosthesis for lower-extremity exercise, standing, and transfers after spinal cord injury.

Authors:  Ronald J Triolo; Stephanie Nogan Bailey; Michael E Miller; Loretta M Rohde; James S Anderson; John A Davis; James J Abbas; Lisa A DiPonio; George P Forrest; David R Gater; Lynda J Yang
Journal:  Arch Phys Med Rehabil       Date:  2012-05       Impact factor: 3.966

6.  Standing after spinal cord injury with four-contact nerve-cuff electrodes for quadriceps stimulation.

Authors:  Lee E Fisher; Michael E Miller; Stephanie N Bailey; John A Davis; James S Anderson; Lori Rhode; Dustin J Tyler; Ronald J Triolo
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2008-10       Impact factor: 3.802

7.  Chronic stability and selectivity of four-contact spiral nerve-cuff electrodes in stimulating the human femoral nerve.

Authors:  L E Fisher; D J Tyler; J S Anderson; R J Triolo
Journal:  J Neural Eng       Date:  2009-07-15       Impact factor: 5.379

8.  On/off control in FES-induced standing up: a model study and experiments.

Authors:  A J Mulder; P H Veltink; H B Boom
Journal:  Med Biol Eng Comput       Date:  1992-03       Impact factor: 2.602

9.  Standing-up exerciser based on functional electrical stimulation and body weight relief.

Authors:  M Ferrarin; E E Pavan; R Spadone; R Cardini; C Frigo
Journal:  Med Biol Eng Comput       Date:  2002-05       Impact factor: 2.602

10.  Evoked EMG versus muscle torque during fatiguing functional electrical stimulation-evoked muscle contractions and short-term recovery in individuals with spinal cord injury.

Authors:  Eduardo H Estigoni; Che Fornusek; Nur Azah Hamzaid; Nazirah Hasnan; Richard M Smith; Glen M Davis
Journal:  Sensors (Basel)       Date:  2014-12-03       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.