Literature DB >> 19548042

The Mark Coventry Award: Articular contact estimation in TKA using in vivo kinematics and finite element analysis.

Fabio Catani1, Bernardo Innocenti, Claudio Belvedere, Luc Labey, Andrea Ensini, Alberto Leardini.   

Abstract

In vivo fluoroscopy is a well-known technique to analyze joint kinematics of the replaced knee. With this method, however, the contact areas between femoral and tibial components, fundamental for monitoring wear and validating design concepts, are hard to identify. We developed and tested a novel technique to assess condylar and post-cam contacts in TKA. The technique uses in vivo motion data of the replaced knee from standard fluoroscopy as input for finite element models of the prosthesis components. In these models, tibiofemoral contact patterns at the condyles and post-cam articulations were calculated during various activities. To test for feasibility, the technique was applied to a bicruciate posterior-stabilized prosthesis. Sensitivity of the finite element analysis, validation of the technique, and in vivo tests were performed. To test for potential in the clinical setting, five patients were preliminarily analyzed during chair rising-sitting, stair climbing, and step up-down. For each task and patient, the condylar contact points and contact line rotation were calculated. The results were repeatable and consistent with corresponding calculations from traditional fluoroscopic analysis. Specifically, natural knee kinematics, which shows rolling back and screw home, seemed replicated in all motor tasks. Post-cam contact was observed on both the anterior and posterior faces. Anterior contact is limited to flexion angle close to extension; posterior contact occurs in deeper flexion but is dependent on the motor task. The data suggest the proposed technique provides reliable information to analyze post-cam contacts.

Entities:  

Mesh:

Year:  2009        PMID: 19548042      PMCID: PMC2795837          DOI: 10.1007/s11999-009-0941-4

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  38 in total

1.  Detrimental kinematics of a flat on flat total condylar knee arthroplasty.

Authors:  J B Stiehl; R D Komistek; D A Dennis
Journal:  Clin Orthop Relat Res       Date:  1999-08       Impact factor: 4.176

2.  Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy.

Authors:  William A. Hoff; Richard D. Komistek; Douglas A. Dennis; Stefan M. Gabriel; Scott A. Walker
Journal:  Clin Biomech (Bristol, Avon)       Date:  1998-10       Impact factor: 2.063

3.  In vivo fluoroscopic analysis of fixed-bearing total knee replacements.

Authors:  Douglas A Dennis; Richard D Komistek; Mohamed R Mahfouz
Journal:  Clin Orthop Relat Res       Date:  2003-05       Impact factor: 4.176

4.  Weight-bearing knee kinematics in subjects with two types of anterior cruciate ligament reconstructions.

Authors:  Izumi Kanisawa; Anne Z Banks; Scott A Banks; Hideshige Moriya; Akihiro Tsuchiya
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2002-12-18       Impact factor: 4.342

5.  Stabilizing mechanisms of the loaded and unloaded knee joint.

Authors:  H H Hsieh; P S Walker
Journal:  J Bone Joint Surg Am       Date:  1976-01       Impact factor: 5.284

6.  Knee biomechanics and total knee replacement.

Authors:  T P Andriacchi; T S Stanwyck; J O Galante
Journal:  J Arthroplasty       Date:  1986       Impact factor: 4.757

7.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee.

Authors:  E S Grood; W J Suntay
Journal:  J Biomech Eng       Date:  1983-05       Impact factor: 2.097

8.  Tibiofemoral movement 2: the loaded and unloaded living knee studied by MRI.

Authors:  P F Hill; V Vedi; A Williams; H Iwaki; V Pinskerova; M A Freeman
Journal:  J Bone Joint Surg Br       Date:  2000-11

9.  Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee.

Authors:  H Iwaki; V Pinskerova; M A Freeman
Journal:  J Bone Joint Surg Br       Date:  2000-11

10.  The effect of an augmentation patella prosthesis versus patelloplasty on revision patellar kinematics and quadriceps tendon force: an ex vivo study.

Authors:  John Mountney; David R Wilson; Michael Paice; Bassam A Masri; Nelson V Greidanus
Journal:  J Arthroplasty       Date:  2008-04-14       Impact factor: 4.757

View more
  18 in total

1.  In vivo determination of cam-post engagement in fixed and mobile-bearing TKA.

Authors:  Sumesh M Zingde; Filip Leszko; Adrija Sharma; Mohamed R Mahfouz; Richard D Komistek; Douglas A Dennis
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

2.  A new spacer-guided, PCL balancing technique for cruciate-retaining total knee replacement.

Authors:  P J C Heesterbeek; L Labey; P Wong; B Innocenti; A B Wymenga
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-08       Impact factor: 4.342

3.  Knee kinetics and kinematics: What are the effects of TKA malconfigurations?

Authors:  Silvia Pianigiani; Luc Labey; Walter Pascale; Bernardo Innocenti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-24       Impact factor: 4.342

4.  Functional versus patient-reported outcome of the bicruciate and the standard condylar-stabilizing total knee arthroplasty.

Authors:  Alberto Vascellari; Stefano Schiavetti; Enrico Rebuzzi; Nicolò Coletti
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-02-27

5.  Design and kinematics in total knee arthroplasty.

Authors:  Vitantonio Digennaro; Francesco Zambianchi; Andrea Marcovigi; Raffaele Mugnai; Francesco Fiacchi; Fabio Catani
Journal:  Int Orthop       Date:  2014-01-14       Impact factor: 3.075

6.  Subject-specific modeling of muscle force and knee contact in total knee arthroplasty.

Authors:  Alessandro Navacchia; Paul J Rullkoetter; Pascal Schütz; Renate B List; Clare K Fitzpatrick; Kevin B Shelburne
Journal:  J Orthop Res       Date:  2016-02-04       Impact factor: 3.494

7.  Can TKA design affect the clinical outcome? Comparison between two guided-motion systems.

Authors:  Raffaele Mugnai; Vitantonio Digennaro; Andrea Ensini; Alberto Leardini; Fabio Catani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-30       Impact factor: 4.342

8.  Differences in the stress distribution in the distal femur between patellofemoral joint replacement and total knee replacement: a finite element study.

Authors:  Hans-Peter W van Jonbergen; Bernardo Innocenti; Gian Luca Gervasi; Luc Labey; Nico Verdonschot
Journal:  J Orthop Surg Res       Date:  2012-06-15       Impact factor: 2.359

9.  More Anterior in vivo Contact Position in Patients With Fixed-Bearing Unicompartmental Knee Arthroplasty During Daily Activities Than in vitro Wear Simulator.

Authors:  Huiyong Dai; Nan Zheng; Diyang Zou; Zhemin Zhu; Ming Han Lincoln Liow; Tsung-Yuan Tsai; Qi Wang
Journal:  Front Bioeng Biotechnol       Date:  2021-05-20

10.  Assessment of paradoxical anterior translation in a CR total knee prosthesis coupling dynamic RSA and FE techniques.

Authors:  Agostino Igor Mirulla; Laura Bragonzoni; Stefano Zaffagnini; Tommaso Ingrassia; Raffaele Zinno; Bernardo Innocenti
Journal:  J Exp Orthop       Date:  2021-07-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.