Literature DB >> 18534488

The effect of an augmentation patella prosthesis versus patelloplasty on revision patellar kinematics and quadriceps tendon force: an ex vivo study.

John Mountney1, David R Wilson, Michael Paice, Bassam A Masri, Nelson V Greidanus.   

Abstract

The purpose of this study was to assess the effect of 2 revision reconstructive interventions on patellofemoral joint mechanics in comparison to control. We flexed 8 cadaver knee specimens from 0 degrees to 60 degrees of flexion in a test rig designed to simulate weight-bearing flexion and extension (Oxford rig). Quadriceps tendon extensor force and patellar kinematics were recorded for control total knee arthroplasty (TKA) (normal primary TKA with patella resurfaced) and then for each of the 2 revision patellar interventions (after patelloplasty of typical revision knee patellar bone defect to leave a simple bony shell, and after TKA with augmentation patella resurfacing). Our results demonstrate that patellar kinematics and quadriceps extensor force are optimized when the patella is reconstructed to normal anteroposterior thickness.

Entities:  

Mesh:

Year:  2008        PMID: 18534488     DOI: 10.1016/j.arth.2007.09.018

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

1.  Biomechanical Analysis of the Use of Stems in Revision Total Knee Arthroplasty.

Authors:  Bernardo Innocenti; Edoardo Bori; Silvia Pianigiani
Journal:  Bioengineering (Basel)       Date:  2022-06-19

2.  The Mark Coventry Award: Articular contact estimation in TKA using in vivo kinematics and finite element analysis.

Authors:  Fabio Catani; Bernardo Innocenti; Claudio Belvedere; Luc Labey; Andrea Ensini; Alberto Leardini
Journal:  Clin Orthop Relat Res       Date:  2009-06-23       Impact factor: 4.176

3.  The influence of malalignment and ageing following sterilisation by gamma irradiation in an inert atmosphere on the wear of ultra-high-molecular-weight polyethylene in patellofemoral replacements.

Authors:  Raman Maiti; Raelene M Cowie; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2017-03-25       Impact factor: 1.617

4.  The influence of kinematic conditions and design on the wear of patella-femoral replacements.

Authors:  Raman Maiti; John Fisher; Liam Rowley; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2014-01-29       Impact factor: 1.617

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.